The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Electrocoagulation processes: A general review about role of electro-generated flocs in pollutant removal
Abstract
Abstract Electrocoagulation (EC) is an acclaimed environmentally adequate approach to wastewater treatment. It is simple and economical by way of reducing the amount of chemical dosage, sludge generation and disposal, and the high costs involved in traditional chemical coagulation (CC). This paper discusses the mechanisms of pollutant removal by electro-generated hydroxide and oxyhydroxide flocs during EC process. The flocs’ generation and formation with Fe, Al and other metal electrodes, and the influence of operating conditions (pH, current density, electrolyte composition, etc.) on floc structure are reviewed. Further, revisions were provided on recent studies about new areas in electro-generated (oxy)hydroxide flocs such as layered double hydroxides (LDHs) and green rusts (GR), common characterization techniques, and factors promoting EC floc production. Results clearly indicate that during EC, the most proposed removal mechanisms of (oxy)hydroxide flocs towards oxyanions, cationic heavy metals, and organic pollutants are adsorption and coprecipitation, charge neutralization and surface complexation, and direct/indirect radical oxidation respectively. EC process alone which has low radical generation is less efficient when treating organic pollutants. Consequently, coupling and combination of AOP-EC generates suitable amounts of radicals and flocs for organic pollutant removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Removal of heavy metal ions from wastewaters: A review
Fu, F., & Wang, Q. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.11.011 · Cited by 8,703
A comprehensive review of electrocoagulation for water treatment: Potentials and challenges
Moussa, D. T., El-Naas, M. H., Nasser, M., & Al-Marri, M. J. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.10.032 · Cited by 963
Comparative study of arsenic removal by iron using electrocoagulation and chemical coagulation
Lakshmanan, D., Clifford, D. A., & Samanta, G. (2010) · Water Research · doi:10.1016/j.watres.2010.06.018 · Cited by 220
Cited by
Environmental impacts and remediation of dye-containing wastewater
Lin, J., Ye, W., Xie, M., Seo, D. H., Luo, J., Wan, Y., & Van der Bruggen, B. (2023) · Nature Reviews Earth & Environment · doi:10.1038/s43017-023-00489-8 · Cited by 900
Recent progress on electrocoagulation process for wastewater treatment: A review
Das, P. P., Sharma, M., & Purkait, M. K. (2022) · Separation and Purification Technology · doi:10.1016/j.seppur.2022.121058 · Cited by 312
Metadata
- Authors
- Tegladza, I. D., Xu, Q., Xu, K., Lv, G., & Lu, J.
- Venue
- Process Safety and Environmental Protection
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 146
- Pages
- 169-189
- ISSN
- 0263-8762 (ISSN-L)
- 0957-5820
- OpenAlex
- W3083605715
- Cited by
- 243
- References
- 3
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrocoagulation processes: A general review about role of electro-generated flocs in pollutant removal. https://app.cochat.ai/papers/10.1016/j.psep.2020.08.048
- The paper
- Tegladza, I. D., Xu, Q., Xu, K., Lv, G., & Lu, J. (2021). Electrocoagulation processes: A general review about role of electro-generated flocs in pollutant removal. Process Safety and Environmental Protection. https://doi.org/10.1016/j.psep.2020.08.048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.