Comparison of Infrared Thermal Detection Systems for mass fever screening in a tropical healthcare setting
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objectives Fever screening systems, such as Infrared Thermal Detection Systems (ITDS), have been used for rapid identification of potential cases during respiratory disease outbreaks for public health management. ITDS detect a difference between the subject and ambient temperature, making deployment in hot climates more challenging. This study, conducted in Singapore, a tropical city, evaluates the accuracy of three different ITDS for fever detection compared with traditional oral thermometry and self-reporting in a clinical setting. Study design This study is a prospective operational evaluation conducted in the Singapore military on all personnel seeking medical care at a high-volume primary healthcare centre over a one week period in February 2014. Methods Three ITDS, the STE Infrared Fever Screening System (IFSS), the Omnisense Sentry MKIII and the handheld Quick Shot Infrared Thermoscope HT-F03B, were evaluated. Temperature measurements were taken outside the healthcare centre, under a sheltered walkway and compared to oral temperature. Subjects were asked if they had fever. Results There were 430 subjects screened, of whom 34 participants (7.9%) had confirmed fever, determined by oral thermometer measurement. The handheld infrared thermoscope had a very low sensitivity (29.4%), but a high specificity (96.8%). The STE ITDS had a moderate sensitivity (44.1%), but a very high specificity (99.1%). Self-reported fevers showed good sensitivity (88.2%) and specificity (93.9%). The sensitivity of the Omnisense ITDS (89.7%) was the highest among the three methods with good specificity (92.0%). Conclusion The new generation Omnisense ITDS displayed a relatively high sensitivity and specificity for fever. Though it has a lower sensitivity, the old generation STE ITDS system showed a very high specificity. Self-reporting of fever was reliable. The handheld thermograph should not be used as a fever-screening tool under tropical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Public health interventions and SARS spread, 2003
Bell, D. M., & World Health Organization Working Group on Prevention of International and Community Transmission of SARS (2004) · Emerging Infectious Diseases · doi:10.3201/eid1011.040729 · Cited by 272
Bitar, D., Goubar, A., & Desenclos, J. C. (2009) · Eurosurveillance · doi:10.2807/ese.14.06.19115-en · Cited by 150 · cited 4×
“Various studies have examined the role of ITDS for fever screening at airports,(8,23) emergency departments(12,14) and outpatient consultations(15) over a range of age groups.(13,24) Caution has been expressed in the use of ITDS, due to several confounders, including individual factors, the targeted body area and envi…”
BackgroundResultInfluential
Cited by
Estimated effectiveness of symptom and risk screening to prevent the spread of COVID-19
Gostic, K., Gomez, A. C., Mummah, R. O., Kucharski, A. J., & Lloyd-Smith, J. O. (2020) · eLife · doi:10.7554/elife.55570 · Cited by 417
Chen, H.-Y., Chen, A., & Chen, C. (2020) · Sensors · doi:10.3390/s20102885 · Cited by 139
“[24] evaluated three types of infrared thermal detection systems for fever screening in tropical conditions and found that the devices with video monitoring had very high specificity and the handheld thermograph could not be used for fever screening.”
BackgroundKhan, S., Saultry, B., Adams, S., Kouzani, A. Z., Decker, K., Digby, R., & Bucknall, T. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.09.012 · Cited by 49
Wang, Q., Zhou, Y., Ghassemi, P., McBride, D., Casamento, J. P., & Pfefer, T. J. (2021) · Sensors · doi:10.3390/s22010215 · Cited by 48
“In several scientific studies, the accuracy of NCITs has been called into question, particularly relative to IRTs [21,22].”
BackgroundFacente, S. N., Hunter, L. A., Packel, L. J., Li, Y., Harte, A., Nicolette, G., McDevitt, S., Petersen, M., & Reingold, A. L. (2021) · BMC Public Health · doi:10.1186/s12889-021-11697-6 · Cited by 19
“However, multiple studies have found low sensitivity or specificity of temperature monitoring during these prior epidemics [8, 9], even in cases where fever was a very common symptom among people with the disease in question [6, 10, 11].”
Background
Metadata
- Authors
- Tay, M. R., Low, Y. L., Zhao, X., Cook, A. R., & Lee, V. J.
- Venue
- Public Health
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 129
- Issue
- 11
- Pages
- 1471-1478
- ISSN
- 0033-3506 (ISSN-L)
- OpenAlex
- W2147564575
- Cited by
- 46
- References
- 2
- FWCI
- 0.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Infrared Thermal Detection Systems for mass fever screening in a tropical healthcare setting. https://app.cochat.ai/papers/10.1016/j.puhe.2015.07.023
- The paper
- Tay, M. R., Low, Y. L., Zhao, X., Cook, A. R., & Lee, V. J. (2015). Comparison of Infrared Thermal Detection Systems for mass fever screening in a tropical healthcare setting. Public Health. https://doi.org/10.1016/j.puhe.2015.07.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.