Cited by 11Fetal and Pediatric Neurological DisordersArtificial Intelligence in Healthcare and EducationPrenatal Screening and Diagnostics

Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison

Open access
Skelton, E., Matthew, J., Li, Y., Khanal, B., Cerrolaza Martinez, J.J., Toussaint, N., Gupta, C., Knight, C. +3 more·2021·Radiography

Abstract

INTRODUCTION: Clinical evaluation of deep learning (DL) tools is essential to compliment technical accuracy metrics. This study assessed the image quality of standard fetal head planes automatically-extracted from three-dimensional (3D) ultrasound fetal head volumes using a customised DL-algorithm. METHODS: weeks). Each had two-dimensional (2D) manually-acquired (2D-MA), 3D operator-selected (3D-OS) and 3D-DL automatically-acquired (3D-DL) images. The proportion of adequate images from each plane and modality, and the number of inadequate images per plane was compared for each method. Inter and intra-observer agreement of overall image quality was calculated. RESULTS: Sixty-seven percent of 3D-OS and 3D-DL transventricular planes were adequate quality. Forty-five percent of 3D-OS and 55% of 3D-DL transcerebellar planes were adequate. Seventy-one percent of 3D-OS and 86% of 3D-DL transventricular planes failed with poor visualisation of intra-cranial structures. Eighty-six percent of 3D-OS and 80% of 3D-DL transcerebellar planes failed due to inadequate visualisation of cerebellar hemispheres. Image quality was significantly different between 2D and 3D, however, no significant difference between 3D-modalities was demonstrated (p < 0.005). Inter-observer agreement of transventricular plane adequacy was moderate for both 3D-modalities, and weak for transcerebellar planes. CONCLUSION: The 3D-DL algorithm can automatically extract standard fetal head planes from 3D-head volumes of comparable quality to operator-selected planes. Image quality in 3D is inferior to corresponding 2D planes, likely due to limitations with 3D-technology and acquisition technique. IMPLICATIONS FOR PRACTICE: Automated image extraction of standard planes from US-volumes could facilitate use of 3DUS in clinical practice, however image quality is dependent on the volume acquisition technique.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.radi.2020.11.006

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Models by Lin et al., Yaqub et al., and Skelton et al. effectively performed image quality assessment of whether a standard plane was correctly acquired.

    “The image quality assessment of whether a standard plane was correctly acquired, either by human operators or by automated extraction from 3D images, was effectively performed by models developed by the research groups of Lin et al. [90], Yaqub et al. [91], and Skelton et al. [92].”

    From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [92]

    The Methods (Quality assessment; page unavailable) state that two human observers assessed whether each plane was adequate. The model automatically extracted planes from 3D images; it did not perform the image-quality assessment attributed to it. (LLM, conf=0.88)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 33 · Cited by 11

Authors
Skelton, E., Matthew, J., Li, Y., Khanal, B., Cerrolaza Martinez, J. J., Toussaint, N., Gupta, C., Knight, C., Kainz, B., Hajnal, J. V., & Rutherford, M.
Affiliations
  • King's College London (GB)
  • Imperial College London (GB)
Corresponding author
Skelton, E.
Venue
Radiography
Publisher
Elsevier BV
Published
2021-05
Volume
27
Issue
2
Pages
519-526
ISSN
1078-8174 (ISSN-L)
OpenAlex
W3107381730
Cited by
11
References
33
Citations by year
2026: 1 · 2025: 2 · 2024: 3 · 2023: 5
FWCI
1.20
Type
journal article
Language
en
Open access
Locations
  • Radiography (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • City Research Online (City University London) (acceptedVersion)
  • Research Portal (King's College London) (submittedVersion, cc-by)
  • Spiral (Imperial College London) (submittedVersion, other-oa)
Funders
Wellcome Trust
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Fetal and Pediatric Neurological Disorders
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
Keywords
3D ultrasound, deep learning, image quality, observer agreement
MeSH terms
Female, Gestational Age, Head, Humans, Infant, Newborn, Pregnancy, Retrospective Studies, Ultrasonography, Prenatal, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review