The DOI matches its Crossref record; 231 of the 246 references it cites were found in a registry or an index; 263 of the 429 sources its claims cite were checked for support.
Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology
Open accessAbstract
A systematic literature review including 189 articles on AI applications in obstetrics and gynecology ultrasound imaging, with 148 focused on obstetrics.
Overview
CoChat Summary
## TL;DR
This systematic review mapped published AI applications in obstetric and gynecologic ultrasound and found far more studies in obstetrics than gynecology: 148 versus 41, out of 189 included articles. The paper concludes that AI can reduce exam time, workload, and variability, but most studies remain technical and have limited clinical applicability.
## Key findings
- The review included 189 articles published from 1994 to 2023; 148 focused on obstetrics and 41 on gynecology.
- In obstetrics, the most represented topics were fetal biometry, fetal echocardiography, neurosonography, gestational age estimation, and workflow analysis; in gynecology, major topics included adnexal masses, breast masses, endometrium, and pelvic floor.
- AI-assisted ultrasound was repeatedly reported to reduce examination time; for pelvic floor studies, reported time dropped from up to 15 minutes to 1.27 seconds.
- For gestational age estimation, the review reports high accuracy with an error of 3.9 to 5 days in some models, and for breast/ovarian mass work, some AI systems matched or outperformed human readers in the cited studies.
## Methods
- The authors conducted a systematic literature review in line with PRISMA, and prospectively registered it in PROSPERO (CRD42023434218).
- They searched PubMed and the Cochrane Library on 14 May 2023, screening English- and German-language records using a PICOS-based approach.
- Inclusion focused on studies using AI with ultrasound in obstetrics or gynecology; studies without AI or US, outside OB/GYN, or using only ultrasound-derived measurements rather than images were excluded.
## Limitations
- The paper states that many AI models still require expert input for image acquisition, ROI selection, and interpretation, and that most studies are technical/preliminary rather than clinically validated.
- The review notes that its search query included the extra keyword “pregnancy,” which likely biased retrieval toward obstetric studies. *(stated in the paper)*
- It also states that including many engineering-literature studies may limit clinical applicability, and that most models lack external validation, real-time use, and testing on pathologic or heterogeneous data. *(stated in the paper)*
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
175 Valid · 12 Not valid · 62 Not checked · 80 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“slow processing times [35,43]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Disputedcites [35] Heuvel, 2019, Automated Fetal Head Detection and Circumference Estimation from Free-Hand Ultrasound Sweeps Using Deep Learning in Resource-Limited Countries, Ultrasound Med. Biol. sourceExperimental — accuracy not yet measured
The “Deployment on low-cost hardware” section says frame classification is fast enough for real-time computation on the study’s training hardware, rather than identifying slow AI processing as a limitation. The “Improvements” section identifies a different delay: the ultrasound device took one minute to save each sweep. (LLM, conf=0.84)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites [43] Chen, 2015, Standard Plane Localization in Fetal Ultrasound via Domain Transferred Deep Neural Networks, IEEE J. Biomed. Health Inform. source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“The image quality assessment of whether a standard plane was correctly acquired, either by human operators or by automated extraction from 3D images, was effectively performed by models developed by the research groups of Lin et al. [90], Yaqub et al. [91], and Skelton et al. [92].”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Not checked — no full text of the sourcecites [90] Lin, 2019, Multi-task learning for quality assessment of fetal head ultrasound images, Med. Image Anal. source
- Not checked — no full text of the sourcecites [91] Yaqub, 2017, A Deep Learning Solution for Automatic Fetal Neurosonographic Diagnostic Plane Verification Using Clinical Standard Constraints, Ultrasound Med. Biol. source
- Disputedcites [92] Skelton, 2021, Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison, Radiography sourceExperimental — accuracy not yet measured
The Methods (Quality assessment; page unavailable) state that two human observers assessed whether each plane was adequate. The model automatically extracted planes from 3D images; it did not perform the image-quality assessment attributed to it. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, US imaging has limitations regarding its comparability and reproducibility.”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 1. Introduction
What the sources say
- Supportedcites [4] Diniz, 2020, Deep Learning Strategies for Ultrasound in Pregnancy, EMJ Reprod. Health source
The Introduction says ultrasound has high inter- and intra-observer variability across different manufacturers’ machines. That directly supports the paraphrased limitations in reproducibility and comparability. (LLM, conf=0.91)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“the possibility of real-time applicability [15,25,32,33]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Supportedcites [15] Baumgartner, 2017, SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound, IEEE Trans. Med. Imaging source
The Abstract states that SonoNet’s convolutional network is designed to operate in real time when detecting fetal standard scan planes and reports a real-time detection experiment. The Introduction (Contributions) also says the system can provide real-time feedback to the operator. (LLM, conf=0.93)
- Supportedcites [25] Płotka, S., Klasa, A., Lisowska, A., Seliga-Siwecka, J., Lipa, M., Trzciński, T., and Sitek, A. (2022). Deep learning fetal ultrasound video model match human observers in biometric measurements. Phys. Med. Biol., 67. source
The Discussion says the automatic approach could be used in real time during routine fetal ultrasound examinations to help identify standard planes. It also notes that this would require installation on the ultrasound device and integration into the workflow; the claim is about the possibility, not an already deployed capability. (LLM, conf=0.93)
- Not checked — no full text of the sourcecites [32] Carneiro, 2008, Detection and Measurement of Fetal Anatomies from Ultrasound Images using a Constrained Probabilistic Boosting Tree, IEEE Trans. Med. Imaging source
- Not checked — no full text of the sourcecites [33] Luo, 2021, A Prenatal Ultrasound Scanning Approach: One-Touch Technique in Second and Third Trimesters, Ultrasound Med. Biol. source
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“the application of a lightweight algorithm in point-of-care devices [18,34,37]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Not checked — no full text of the sourcecites [18] Zeng, 2022, Efficient fetal ultrasound image segmentation for automatic head circumference measurement using a lightweight deep convolutional neural network, Med. Phys. source
- Partly supportedcites [34] Zeng, 2021, Fetal Ultrasound Image Segmentation for Automatic Head Circumference Biometry Using Deeply Supervised Attention-Gated V-Net, J. Digit. Imaging sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) describes point-of-care use as a potential application and reports a 6.3 ms execution time on a computer. The Introduction (page unavailable) says the attention modules add few parameters at low computational cost. The paper does not report applying the algorithm on point-of-care devices or using it to acquire standard planes; it studies head segmentation and circumference measurement from existing images. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [37] Yang, C., Yang, Z., Liao, S., Guo, J., Yin, S., Liu, C., and Kang, Y. (2022). A new approach to automatic measure fetal head circumference in ultrasound images using convolutional neural networks. Comput. Biol. Med., 147. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
198 more claims · 120 with their cited sources checked
Create a free account to see all 329 claims and every source verdict.
- It may state two separate claims as one. 69
- Probably not a substantial claim. 69
- The quote only partly states this claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Self-check results appear here once an independent check has confirmed them.
Cited works that were retracted
Works this paper cites that were later retracted, from the retraction notices publishers deposit. Major when the notice came out before this paper was published.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
Cited work 10.1155/2022/3269692 · retracted 2023-10-11 · notice 10.1155/2023/9850459 · this paper published 2023-10-29
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
Cited work 10.1155/2021/4405189 · retracted 2023-10-11 · notice 10.1155/2023/9762610 · this paper published 2023-10-29
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“The model of He et al. addressed the challenge of the identification and classification of intrauterine pregnancy residues that had the potential to reduce associated complications and improve surgical outcomes of curettages [167].”
Cited work 10.1155/2022/9937051 · retracted 2023-10-18 · notice 10.1155/2023/9780604 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“These algorithms may improve medical diagnosis and potentially reduce clinical workload by replacing the sonographer’s manual tracing [168].”
Cited work 10.1155/2022/4010339 · retracted 2023-12-06 · notice 10.1155/2023/9792545 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“Han, G., Jin, T., Zhang, L., Guo, C., Gui, H., Na, R., Wang, X., and Bai, H. (2022). Adoption of Compound Echocardiography under Artificial Intelligence Algorithm in Fetal Congenial Heart Disease Screening during Gestation. Appl. Bionics Biomech., 2022.”
Cited work 10.1155/2022/6410103 · retracted 2023-11-29 · notice 10.1155/2023/9814523 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“Lastly, the studies of Burgos-Artizzu et al. and Sreelakshmy et al. portrayed AI methods for the estimation of GA through an analysis of transthalamic axial planes or cerebellum measurements [95,96].”
Cited work 10.1155/2022/8342767 · retracted 2023-12-29 · notice 10.1155/2023/9852080 · this paper published 2023-10-29
Citations
Cites
6 retracted
[Retracted] An Automated Deep Learning Model for the Cerebellum Segmentation from Fetal Brain Images
Sreelakshmy, R., Titus, A., Sasirekha, N., Logashanmugam, E., Begam, R. B., Ramkumar, G., & Raju, R. (2022) · BioMed Research International · doi:10.1155/2022/8342767 · Cited by 51 · cited 1×
“Lastly, the studies of Burgos-Artizzu et al. and Sreelakshmy et al. portrayed AI methods for the estimation of GA through an analysis of transthalamic axial planes or cerebellum measurements [95,96].”
MethodRetractedHan, G., Jin, T., Zhang, L., Guo, C., Gui, H., Na, R., Wang, X., & Bai, H. (2022) · Applied Bionics and Biomechanics · doi:10.1155/2022/6410103 · Cited by 23
RetractedLiu, S., Sun, Y., & Luo, N. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/4405189 · Cited by 11
RetractedWang, Q., Liu, D., & Liu, G. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/4010339 · Cited by 11 · cited 2×
“These algorithms may improve medical diagnosis and potentially reduce clinical workload by replacing the sonographer’s manual tracing [168].”
RetractedZhang, Y., Hou, J., Wang, Q., Hou, A., & Liu, Y. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/3269692 · Cited by 6
RetractedHe, H., Liu, R., Zhou, X., Zhang, Y., Yu, B., Xu, Z., & Huang, H. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/9937051 · Cited by 3 · cited 1×
“The model of He et al. addressed the challenge of the identification and classification of intrauterine pregnancy residues that had the potential to reduce associated complications and improve surgical outcomes of curettages [167].”
MethodRetractedSung, H., Ferlay, J., Siegel, R. L., Laversanne, M., Soerjomataram, I., Jemal, A., & Bray, F. (2021) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21660 · Cited by 108,699 · cited 1×
“Breast cancer represents the most common malignancy in women worldwide and its incidence still shows a rising tendency [195].”
BackgroundThe PRISMA 2020 statement: An updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n71 · Cited by 108,283
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682 · cited 1×
“Biometric calculations are based on the acquisition of standard planes for measurements of fetal head circumference (HC), abdominal circumference (AC), and femur length [14].”
Background
Cited by
Guillen-Grima, F., Guillen-Aguinaga, S., Guillen-Aguinaga, L., Alas-Brun, R., Onambele, L., Ortega, W., Montejo, R., Aguinaga-Ontoso, E., Barach, P., & Aguinaga-Ontoso, I. (2023) · Clinics and Practice · doi:10.3390/clinpract13060130 · Cited by 72
Progress in the Application of Artificial Intelligence in Ultrasound-Assisted Medical Diagnosis
Li, Y., Li, Q., Fu, K., Zhou, X., & Zhang, K. (2025) · Bioengineering · doi:10.3390/bioengineering12030288 · Cited by 84
“This evolution is effectively dismantling traditional limitations in ultrasound examinations, improving imaging quality, optimizing procedural workflows, and advancing the field of ultrasound medicine toward precision healthcare.”
Stringer, J. S. A., Pokaprakarn, T., Prieto, J. C., Vwalika, B., Chari, S. V., Sindano, N., Freeman, B. L., Sikapande, B., Davis, N. M., Sebastião, Y. V., et al. (2024) · JAMA · doi:10.1001/jama.2024.10770 · Cited by 68
Brandão, M., Mendes, F., Martins, M., Cardoso, P., Macedo, G., Mascarenhas, T., & Mascarenhas, M. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13041061 · Cited by 39
“Nevertheless, there is a need to understand the limitations of the available clinical imaging methods, namely clinician workload and intra and interobserver variability, and AI has the potential to overcome these limitations while increasing diagnostic accuracy [23].”
BackgroundQuality of ChatGPT-Generated Therapy Recommendations for Breast Cancer Treatment in Gynecology
Stalp, J. L., Denecke, A., Jentschke, M., Hillemanns, P., & Klapdor, R. (2024) · Current Oncology · doi:10.3390/curroncol31070284 · Cited by 31
“Since this research is often lacking clinical applicability [2], these systems are not implemented in daily medical treatment routines, therapy recommendations or patient care in Germany.”
BackgroundMethod
Metadata
- Authors
- Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F.
- Affiliations
- University Hospital Bonn (DE)
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
- Corresponding author
- Recker, Florian
- ORCID
- Venue
- Journal of Clinical Medicine
- Publisher
- MDPI AG
- Published
- 2023-10-29
- Volume
- 12
- Issue
- 21
- Pages
- 6833
- ISSN
- 2077-0383 (ISSN-L)
- PMC
- PMC10649694
- OpenAlex
- W4388105557
- Cited by
- 44
- References
- 246
- Citations by year
- 2026: 7 · 2025: 16 · 2024: 20 · 2023: 1
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Clinical Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by-nc-sa)
- PubMed (publishedVersion)
- bonndoc (University of Bonn) (submittedVersion, cc-by)
- PuSH - Publication Server of Helmholtz Zentrum München (submittedVersion)
- Funders
- Open Access Publication Fund of the University of Bonn
- Topics
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Keywords
- artificial intelligence, ultrasonography, obstetrics, gynecology, anatomical measurements, pathology detection, fetal biometry, echocardiography, neurosonography, adnexal mass, breast mass, endometrial assessment, pelvic floor assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology. https://app.cochat.ai/papers/10.3390/jcm12216833
- The paper
- Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023). Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology. Journal of Clinical Medicine. https://doi.org/10.3390/jcm12216833
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.