CoChat

A new polystyrene-based ionomer/MWCNT nanocomposite for wearable skin temperature sensors

Open access
Giuliani, Alessio, Placidi, Massimo, Di Francesco, Fabio, Pucci, Andrea · 2014 · Reactive and Functional Polymers
Cited by 51

The DOI matches its Crossref record.

Abstract

The present work outlines the fabrication and testing of a novel skin temperature sensor based on exfoliated and undamaged multi-walled carbon nanotubes (MWCNTs) dispersed in a poly(vinylbenzyl chloride) derivative with triethylamine (PVBC_Et 3 N). The dispersions were prepared by sonicating MWCNT/PVBC_Et 3 N mixtures in dimethylformamide for 5 min and the quantification of the MWCNTs dispersed was evaluated by UV–vis spectroscopy investigations and thermogravimetric analyses. The investigations demonstrated the realization of MWCNT/PVBC_Et 3 N sensors with a resistance sensitivity to temperature close to −0.004 K −1 , an absolute value that is comparable to the highest values found in metals. The temperature dependence of the resistance was also found very reproducible in the range 20–40 °C, thus suggesting the possibility of using the MWCNT/PVBC_Et 3 N system for the fabrication of small wearable temperature sensors for the monitoring of chronic wounds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.reactfunctpolym.2014.01.008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Giuliani, A., Placidi, M., Di Francesco, F., & Pucci, A.
Venue
Reactive and Functional Polymers
Publisher
Elsevier BV
Published
2014-03
Volume
76
Pages
57-62
ISSN
1381-5148 (ISSN-L)
OpenAlex
W1993449953
Cited by
51
References
0
FWCI
2.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.