Temperature- and pH-sensitive wearable materials for monitoring foot ulcers

Open access

Abstract

Foot ulcers account for 15% of comorbidities associated with diabetes. Presently, no device allows the status of foot ulcers to be continuously monitored when patients are not hospitalized. In this study, we describe a temperature and a pH sensor capable of monitoring diabetic foot and venous leg ulcers developed in the frame of the seventh framework program European Union project SWAN-iCare (smart wearable and autonomous negative pressure device for wound monitoring and therapy). Temperature is measured by exploiting the variations in the electrical resistance of a nanocomposite consisting of multiwalled carbon nanotubes and poly(styrene-b-(ethylene- co -butylene)-b-styrene). The pH sensor used a graphene oxide (GO) layer that changes its electrical potential when pH changes. The temperature sensor has a sensitivity of ~85 Ω/°C in the range 25°C–50°C and a high repeatability (maximum standard deviation of 0.1% over seven repeated measurements). For a GO concentration of 4 mg/mL, the pH sensor has a sensitivity of ~42 mV/pH and high linearity (R 2 =0.99). Keywords: diabetic foot ulcer, wearable sensors, wound temperature, wound pH

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2147/ijn.s121726

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The temperature sensor. Notes: Left: drawing of the Kapton substrate for the temperature sensor. Right: substrate with an electrode pair coated by a film of MWCNTs–SEBS. Abbreviations: MWCNTs, multiwalled carbon nanotubes; SEBS, poly(styrene-b-(ethylene-co-butylene)-b-styrene).
Figure 1 The temperature sensor. Notes: Left: drawing of the Kapton substrate for the temperature sensor. Right: substrate with an electrode pair coated by a film of MWCNTs–SEBS. Abbreviations: MWCNTs, multiwalled carbon nanotubes; SEBS, poly(styrene-b-(ethylene-co-butylene)-b-styrene).CC BY-NC · PubMed Central
Figure 2 Screen-printed board used for the pH measurement. Notes: The WE is coated with a graphene oxide layer. The RE is Ag/AgCl. Abbreviations: CE, counter electrode; RE, reference electrode; WE, working electrode.
Figure 2 Screen-printed board used for the pH measurement. Notes: The WE is coated with a graphene oxide layer. The RE is Ag/AgCl. Abbreviations: CE, counter electrode; RE, reference electrode; WE, working electrode.CC BY-NC · PubMed Central
Figure 3 TEM and SEM images of MWCNTs-SEBS and graphene oxide, respectively. Notes: (A) TEM image of a MWCNTs–SEBS composite after a 5-minute sonication. The MWCNTs are well dispersed (SEBS are not visible in TEM). (B) Scanning electron microscopy image of a graphene oxide layer. Abbreviations: MWCNTs, multiwalled carbon nanotubes; SEBS, poly(styrene-b-(ethylene-co-butylene)-b-styrene); TEM, transmission electron microscopy; SEM, scanning electron microscope.
Figure 3 TEM and SEM images of MWCNTs-SEBS and graphene oxide, respectively. Notes: (A) TEM image of a MWCNTs–SEBS composite after a 5-minute sonication. The MWCNTs are well dispersed (SEBS are not visible in TEM). (B) Scanning electron microscopy image of a graphene oxide layer. Abbreviations: MWCNTs, multiwalled carbon nanotubes; SEBS, poly(styrene-b-(ethylene-co-butylene)-b-styrene); TEM, transmission electron microscopy; SEM, scanning electron microscope.CC BY-NC · PubMed Central
Figure 4 Calibration curve of a 20% w/w multiwalled carbon nanotubes–poly(styrene-b-(ethylene-co-butylene)-b-styrene) nanocomposite.
Figure 4 Calibration curve of a 20% w/w multiwalled carbon nanotubes–poly(styrene-b-(ethylene-co-butylene)-b-styrene) nanocomposite.CC BY-NC · PubMed Central
Figure 5 Calibration curves for three GO pH sensors obtained at three different GO concentrations: (A) 0.04 mg/mL, (B) 0.4 mg/mL, and (C) 4 mg/mL. Note: Sensitivity increases with increasing concentrations. Abbreviation: GO, graphene oxide.
Figure 5 Calibration curves for three GO pH sensors obtained at three different GO concentrations: (A) 0.04 mg/mL, (B) 0.4 mg/mL, and (C) 4 mg/mL. Note: Sensitivity increases with increasing concentrations. Abbreviation: GO, graphene oxide.CC BY-NC · PubMed Central
Figure 6 Test of the GO pH sensor in human plasma in comparison with a commercial pH meter. Note: The GO sensor and the pH meter were always immersed in human plasma during the test. Abbreviation: GO, graphene oxide.
Figure 6 Test of the GO pH sensor in human plasma in comparison with a commercial pH meter. Note: The GO sensor and the pH meter were always immersed in human plasma during the test. Abbreviation: GO, graphene oxide.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Research works printed but not linked: 1

  1. [24]Nagoba BS Suryawanshi NM Wadher B Selkar S Acidic environment and wound healing: a review Wounds 2015 27 1 5 11

Cited by

See all 76

Metadata

Authors
Salvo, P., Calisi, N., Melai, B., Dini, V., Paoletti, C., Lomonaco, T., Pucci, A., Di Francesco, F., Piaggesi, A., & Romanelli, M.
Affiliations
University of Pisa (IT)
Corresponding author
Romanelli, Marco
Venue
International Journal of Nanomedicine
Published
2017-01
Volume
Volume 12
Pages
949-954
ISSN
  • 1176-9114 (ISSN-L)
  • 1178-2013
OpenAlex
W2583551110
Cited by
76
References
42
Citations by year
2026: 3 · 2025: 8 · 2024: 5 · 2023: 13 · 2022: 5 · 2021: 12 · 2020: 9 · 2019: 11 · 2018: 8 · 2017: 2
FWCI
3.69
Type
journal article
Language
en
Open access
Locations
  • International Journal of Nanomedicine (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Dove Medical Press (Taylor and Francis Group) (submittedVersion, cc-by-nc)
Funders
  • European Commission (317894)
  • FP7 Information and Communication Technologies
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Surgery › Wound Healing and Treatments
Keywords
diabetic foot ulcer, venous leg ulcers, wearable sensors, temperature sensors, pH sensor, wound monitoring, multi-walled carbon nanotubes, graphene oxide, electrical resistance, nanocomposites
MeSH terms
Equipment Design, Graphite, Humans, Hydrogen-Ion Concentration, Polyethylenes, Polystyrenes, Pressure, Sensitivity and Specificity, Temperature, Foot Ulcer, Diabetic Foot, Monitoring, Ambulatory, Nanotubes, Carbon, Nanomedicine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temperature- and pH-sensitive wearable materials for monitoring foot ulcers. https://app.cochat.ai/papers/10.2147/ijn.s121726
The paper
Salvo, P., Calisi, N., Melai, B., Dini, V., Paoletti, C., Lomonaco, T., Pucci, A., Di Francesco, F., Piaggesi, A., & Romanelli, M. (2017). Temperature- and pH-sensitive wearable materials for monitoring foot ulcers. International Journal of Nanomedicine. https://doi.org/10.2147/ijn.s121726

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.