The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
CFD simulation of cross-ventilation in buildings using rooftop wind-catchers: Impact of outlet openings
Open accessAbstract
Cross-ventilation using rooftop wind-catchers is very complex as it is influenced by a wide range of interrelated factors including aerodynamic characteristics of the wind catcher, approach-flow conditions and building geometry. Earlier studies on wind-driven cross-ventilation in buildings have shown the significant impact of the geometry and position of openings on the flow and ventilation performance. However, this has not yet been investigated for cross-ventilation using wind catchers. This paper, therefore, presents a detailed evaluation of the impact of the outlet openings on the ventilation performance of a single-zone isolated building with a wind catcher. The evaluation is based on three ventilation performance indicators: (i) induced airflow rate, (ii) age of air, and (iii) air change efficiency. High-resolution coupled 3D steady RANS CFD simulations of cross-ventilation are performed for different sizes and types of outlet openings. The CFD simulations are validated based on wind-tunnel measurements. The results show that using outlet openings very close to the wind catcher will not increase the induced airflow, while it leads to a considerable reduction in the indoor air quality. A combination of one-sided wind-catcher and window is superior, while the use of two-sided wind-catchers leads to the lowest indoor air quality and air change efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-equation eddy-viscosity turbulence models for engineering applications
Menter, F. R. (1994) · AIAA Journal · doi:10.2514/3.12149 · Cited by 21,593
A new k-ε eddy viscosity model for high Reynolds number turbulent flows
Shih, T.-H., Liou, W. W., Shabbir, A., Yang, Z., & Zhu, J. (1995) · Computers & Fluids · doi:10.1016/0045-7930(94)00032-t · Cited by 6,119
Development of turbulence models for shear flows by a double expansion technique
Yakhot, V., Orszag, S. A., Thangam, S., Gatski, T. B., & Speziale, C. G. (1992) · Physics of Fluids A: Fluid Dynamics · doi:10.1063/1.858424 · Cited by 2,832
Cited by
On the accuracy of turbulence models for CFD simulations of vertical axis wind turbines
Rezaeiha, A., Montazeri, H., & Blocken, B. (2019) · Energy · doi:10.1016/j.energy.2019.05.053 · Cited by 380
Self-citationAhmed, T., Kumar, P., & Mottet, L. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110669 · Cited by 270
Wind Flow Characteristics on a Vertical Farm with Potential Use of Energy Harvesting
Xie, S., Martinez-Vazquez, P., & Baniotopoulos, C. (2024) · Buildings · doi:10.3390/buildings14051278 · Cited by 11
Metadata
- Authors
- Montazeri, H., & Montazeri, F.
- Venue
- Renewable Energy
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 118
- Pages
- 502-520
- ISSN
- 0960-1481 (ISSN-L)
- OpenAlex
- W2769917360
- Cited by
- 175
- References
- 3
- FWCI
- 11.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.