Cited by 54Refrigeration and Air Conditioning TechnologiesAdsorption and Cooling SystemsBuilding Energy and Comfort Optimization

A new frosting map of variable-frequency air source heat pump in severe cold region considering the variation of heating load

Wei, Wenzhe, Ni, Long, Li, Shuyi, Wang, Wei, Yao, Yang, Xu, Laifu, Yang, Yahua·2020·Renewable Energy

Integrity signals

Registry

Crossref · 10.1016/j.renene.2020.07.087

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Frost inevitably forms on the outdoor heat exchanger surface when its surface temperature is below both the dew point of air and the freezing point of water during ASHP heating.

    “if the outdoor heat exchanger surface temperature is below both the dew point temperature of air and the freezing point temperature of the water, frost would inevitably generate on the surface of the outdoor heat exchangers when the ASHP system works in the heating mode [7,8].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wei, W., Ni, L., Li, S., Wang, W., Yao, Y., Xu, L., & Yang, Y.
Affiliations
  • Harbin Institute of Technology (CN)
  • Beijing University of Technology (CN)
Corresponding author
Ni, Long
Venue
Renewable Energy
Publisher
Elsevier BV
Published
2020-12
Volume
161
Pages
184-199
ISSN
0960-1481 (ISSN-L)
OpenAlex
W3045235308
Cited by
54
References
0
Citations by year
2026: 7 · 2025: 12 · 2024: 12 · 2023: 9 · 2022: 7 · 2021: 7
FWCI
2.83
Type
journal article
Language
en
Open access
closed
Locations
  • Renewable Energy (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
National Natural Science Foundation of China (51878209)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
air-source heat pump, variable frequency operation, vapor injection, frost formation, severe cold regions, heating load, critical relative humidity, outdoor temperature, space heating

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review