CoChat

The incidence of “load&go” out-of-hospital cardiac arrest candidates for emergency department utilization of emergency extracorporeal life support: A one-year review

Open access
Poppe, Michael, Weiser, Christoph, Holzer, Michael, Sulzgruber, Patrick, Datler, Philip, Keferböck, Markus, Zeiner, Sebastian, Lobmeyr, Elisabeth, van Tulder, Raphael, Ziegler, Andreas, Glück, Harald, Meixner, Manfred, Schrattenbacher, Georg, Maszar, Henrik, Zajicek, Andreas, Sterz, Fritz, Schober, Andreas · 2015 · Resuscitation
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The outcome of patients after out-of-hospital cardiac arrest (OHCA) is poor and gets worse after prolonged resuscitation. Recently introduced attempts like an early installed emergency extracorporeal life support (E-ECLS) in patients with persisting cardiac arrest at the emergency department (ED) are tried. The "Vienna Cardiac Arrest Registry" (VICAR) was introduced August 2013 to collect Utstein-style data. The aim of this observational study was to identify the incidence of patients which fulfil "load&go"-criteria for E-ECLS at the ED. METHODS: VICAR was retrospectively analyzed for following criteria: age <75 years; witnessed OHCA; basic life support; ventricular fibrillation/ventricular tachycardia; no return-of-spontaneous-circulation (ROSC) within 15 min of advanced-life-support, which were supposed as potential optimal criteria for "load&go" plus successful E-ECLS treatment at the ED. The observation period was from August 1, 2013 to July 31, 2014. RESULTS: Over 948 OHCA patients registered during the study period; data were exploitable for 864 patients. Of all patients, "load&go"-criteria were fulfilled by 55 (6%). However, 96 (11%) were transported with on-going CPR to the ED. Of these 96 patients, only 16 (17%) met the "load&go"-criteria. Similarly, among the 96 patients, 12 adults were treated with E-ECLS at the ED, with only 5 meeting the criteria. Among these 12 patients, favourable neurological outcome (CPC 1/2) was obtained in 1 patient without criteria. CONCLUSION: Further promotion of these criteria within the ambulance crews is needed. May be these criteria could serve as a decision support for emergency physicians/paramedics, which patients to transport with on-going CPR to the ED for E-ECLS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.resuscitation.2015.03.003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 64

Metadata

Authors
Poppe, M., Weiser, C., Holzer, M., Sulzgruber, P., Datler, P., Keferböck, M., Zeiner, S., Lobmeyr, E., van Tulder, R., Ziegler, A., Glück, H., Meixner, M., Schrattenbacher, G., Maszar, H., Zajicek, A., Sterz, F., & Schober, A.
Venue
Resuscitation
Publisher
Elsevier BV
Published
2015-06
Volume
91
Pages
131-136
ISSN
0300-9572 (ISSN-L)
OpenAlex
W2067854347
Cited by
64
References
1
FWCI
8.92
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The incidence of “load&go” out-of-hospital cardiac arrest candidates for emergency department utilization of emergency extracorporeal life support: A one-year review. https://app.cochat.ai/papers/10.1016/j.resuscitation.2015.03.003
The paper
Poppe, M., Weiser, C., Holzer, M., Sulzgruber, P., Datler, P., Keferböck, M., Zeiner, S., Lobmeyr, E., van Tulder, R., Ziegler, A., Glück, H., Meixner, M., Schrattenbacher, G., Maszar, H., Zajicek, A., Sterz, F., & Schober, A. (2015). The incidence of “load&go” out-of-hospital cardiac arrest candidates for emergency department utilization of emergency extracorporeal life support: A one-year review. Resuscitation. https://doi.org/10.1016/j.resuscitation.2015.03.003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.