A novel, flexible and automated manufacturing facility for cell-based health care products: tissue Factory
Open accessAbstract
INTRODUCTION: Current production facilities for Cell-Based Health care Products (CBHPs), also referred as Advanced-Therapy Medicinal Products or Regenerative Medicine Products, are still dependent on manual work performed by skilled workers. A more robust, safer and efficient manufacturing system will be necessary to meet the expected expansion of this industrial field in the future. Thus, the 'flexible Modular Platform (fMP)' was newly designed to be a true "factory" utilizing the state-of-the-art technology to replace conventional "laboratory-like" manufacturing methods. Then, we built the Tissue Factory as the first actual entity of the fMP. METHODS: The Tissue Factory was designed based on the fMP in which several automated modules are combined to perform various culture processes. Each module has a biologically sealed chamber that can be decontaminated by hydrogen peroxide. The asepticity of the processing environment was tested according to a pharmaceutical sterility method. Then, three procedures, production of multi-layered skeletal myoblast sheets, expansion of human articular chondrocytes and passage culture of human induced pluripotent stem cells, were conducted by the system to confirm its ability to manufacture CHBPs. RESULTS: Falling or adhered microorganisms were not detected either just after decontamination or during the cell culture processes. In cell culture tests, multi-layered skeletal myoblast sheets were successfully manufactured using the method optimized for automatic processing. In addition, human articular chondrocytes and human induced-pluripotent stem cells could be propagated through three passages by the system at a yield comparable to manual operations. CONCLUSIONS: The Tissue Factory, based on the fMP, successfully reproduced three tentative manufacturing processes of CBHPs without any microbial contamination. The platform will improve the manufacturability in terms of lower production cost, improved quality variance and reduced contamination risks. Moreover, its flexibility has the potential to adapt to the modern challenges in the business environment including employment issues, low operational rates, and relocation of facilities. The fMP is expected to become the standard design basis of future manufacturing facilities for CBHPs.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Automated isolator-based platforms represent a paradigm shift towards scalable, cost-effective, and standardized production of cell-based healthcare products.
“Such automated isolator-based platforms represent a paradigm shift towards scalable, cost-effective, and standardized production of cell-based healthcare products (Kikuchi et al., 2018).”
From Isolator-based point-of-care manufacturing: a practical solution for GMP-compliant cell and extracellular vesicles therapy production (2025) · cites this paper as Kikuchi et al., 2018
The Conclusion and Discussion (‘Modularity, flexibility and cost-effectiveness’; page not provided) describe a novel automated isolator-based platform expected to lower costs, improve quality consistency, and support multiple batches. But these are largely projected benefits, and parallel production is conditional on resolving regulatory issues; the paper does not establish scalable, cost-effective, standardized production as an achieved paradigm shift. (LLM, conf=0.86)
Experimental — accuracy not yet measuredThe Tissue Factory, an automated isolator-based platform, successfully manufactured multi-layered skeletal myoblast sheets, expanded human articular chondrocytes, and cultured human iPSCs across multiple passages without microbial contamination, demonstrating robust performance comparable to manual operations while minimizing operator intervention and contamination risks.
“This system successfully manufactured multi-layered skeletal myoblast sheets, expanded human articular chondrocytes, and cultured human iPSCs across multiple passages without microbial contamination, demonstrating robust performance comparable to manual operations while minimizing operator intervention and contamination risks.”
From Isolator-based point-of-care manufacturing: a practical solution for GMP-compliant cell and extracellular vesicles therapy production (2025) · cites this paper as Kikuchi et al., 2018
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Nakagawa, M., Taniguchi, Y., Senda, S., Takizawa, N., Ichisaka, T., Asano, K., Morizane, A., Doi, D., Takahashi, J., Nishizawa, M., et al. (2014) · Scientific Reports · doi:10.1038/srep03594 · Cited by 673 · see citing works
Long-term maintenance of human induced pluripotent stem cells by automated cell culture system
Konagaya, S., Ando, T., Yamauchi, T., Suemori, H., & Iwata, H. (2015) · Scientific Reports · doi:10.1038/srep16647 · Cited by 94 · see citing works
Flagged first, then by citations
Research works printed but not linked: 20
- [2]Bubela T. McCabe C. Archibald P. Atkins H. Bradshaw S.E. Kefalas P. Bringing regenerative medicines to the clinic: the future for regulation and reimbursement Regen Med 10 2015 897 911 26565607
- [3]Mount N.M. Ward S.J. Kefalas P. Hyllner J. Cell-based therapy technology classifications and translational challenges Philos Trans R Soc B Biol Sci 370 2015 20150017 PMC4634004 26416686
- [4]Lopez F. Di Bartolo C. Piazza T. Passannanti A. Gerlach J.C. Gridelli B. A quality risk management model approach for cell therapy manufacturing Risk Anal 30 2010 1857 1871 20723148
- [5]Ratcliffe E. Thomas R.J. Williams D.J. Current understanding and challenges in bioprocessing of stem cell-based therapies for regenerative medicine Br Med Bull 100 2011 137 155 21852279
- [6]Hümmer C. Poppe C. Bunos M. Stock B. Wingenfeld E. Huppert V. Automation of cellular therapy product manufacturing: results of a split validation comparing CD34 selection of peripheral blood stem cell apheresis product with a semi-manual vs. an automatic procedure J Transl Med 14 2016 76 26983643 PMC4793541
- [7]Knoll A. Scherer T. Poggendorf I. Lutkemeyer D. Jurgen L. Flexible automation of cell culture and tissue engineering tasks Biotechnol Prog 20 2004 1825 1835 15575718
- [8]Franscini N. Wuertz K. Patocchi-Tenzer I. Durner R. Boos N. Graf-Hausner U. Development of a novel automated cell isolation, expansion, and characterization platform J Lab Autom 16 2011 204 213 21609703
- [10]Hyslop L. Prathalingam N. Nowak L. Fenwick J. Harbottle S. Byerley S. A novel isolator-based system promotes viability of human embryos during laboratory processing PLoS One 7 2012 PMC3290619 22393356
- [11]Kino-oka M. Taya M. Recent developments in processing systems for cell and tissue cultures toward therapeutic application J Biosci Bioeng 108 2009 267 276 19716513
- [12]Okano T. Yamada N. Sakai H. Sakurai Y. A novel recovery system for cultured cells using plasma-treated polystyrene dishes grafted with poly(N-isopropylacrylamide) J Biomed Mater Res 27 1993 1243 1251 8245039
- [13]Takahashi K. Tanabe K. Ohnuki M. Narita M. Ichisaka T. Tomoda K. Induction of pluripotent stem cells from adult human fibroblasts by defined factors Cell 131 2007 861 872 18035408
- [15]Thomson J. Itskovitz-Eldor J. Shapiro S. Waknitz M. Swiergiel J. Marshall V. Embryonic stem cell lines derived from human blastocysts Science 282 1989 1145 1147 9804556
- [16]Onuma Y. Tateno H. Hirabayashi J. Ito Y. Asashima M. RBC2LCN, a new probe for live cell imaging of human pluripotent stem cells Biochem Biophys Res Commun 431 2013 524 529 23321312
- [17]Sawa Y. Miyagawa S. Sakaguchi T. Fujita T. Matsuyama A. Saito A. Tissue engineered myoblast sheets improved cardiac function sufficiently to discontinue LVAS in a patient with DCM: report of a case Surg Today 42 2012 181 184 22200756
- [18]Sawa Y. Yoshikawa Y. Toda K. Fukushima S. Yamazaki K. Ono M. Safety and efficacy of autologous skeletal myoblast sheets (TCD-51073) for the treatment of severe chronic heart failure due to ischemic heart disease Circ J 79 2015 991 999 25912561
- [19]Sekiya N. Matsumiya G. Miyagawa S. Saito A. Shimizu T. Okano T. Layered implantation of myoblast sheets attenuates adverse cardiac remodeling of the infarcted heart J Thorac Cardiovasc Surg 138 2009 985 993 19769884
- [20]Kubo H. Shioyama T. Oura M. Suzuki A. Ogawa T. Makino H. Development of automated 3-dimensional tissue fabrication system tissue factory – automated cell isolation from tissue for regenerative medicine Conf Proc IEEE Eng Med Biol Soc 2013 2013 358 361 24109698
- [21]Haraguchi Y. Shimizu T. Sasagawa T. Sekine H. Sakaguchi K. Kikuchi T. Fabrication of functional three-dimensional tissues by stacking cell sheets in vitro Nat Protoc 7 2012 850 858 22481530
- [22]Kikuchi T. Shimizu T. Wada M. Yamato M. Okano T. Automatic fabrication of 3-dimensional tissues using cell sheet manipulator technique Biomaterials 35 2014 2428 2435 24370007
- [23]Nguyen K. Process automation in manufacturing of mesenchymal stromal cells Transfusion 56 2016 26S 28S 27079319
Cited by
Sorted by citations
Chiu, Y.-S., Wang, K.-L., & Wu, K.-L. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1644318 · Cited by 17 · see citing works
- Authors
- Kikuchi, T., Kino-oka, M., Wada, M., Kobayashi, T., Kato, M., Takeda, S., Kubo, H., Ogawa, T., Sunayama, H., Tanimoto, K., Mizutani, M., Shimizu, T., & Okano, T.
- Affiliations
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University (JP)
- ABLE Corporation (Japan) (JP)
- Hitachi (Japan) (JP)
- Nihon Kohden (Japan) (JP)
- Shibuya (Japan) (JP)
- The University of Osaka (JP)
- Corresponding author
- Shimizu, Tatsuya
- ORCID
- Venue
- Regenerative Therapy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 9
- Pages
- 89-99
- ISSN
- 2352-3204 (ISSN-L)
- PMC
- PMC6223031
- OpenAlex
- W2891572931
- Cited by
- 37
- References
- 2
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 5 · 2023: 4 · 2022: 2 · 2021: 7 · 2020: 6 · 2019: 5
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Regenerative Therapy (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Japan Agency for Medical Research and Development (JP16be0204439)
- Cabinet Office, Government of Japan
- Japan Society for the Promotion of Science
- Topics
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Industrial and Manufacturing Engineering › Flexible and Reconfigurable Manufacturing Systems
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Viral Infectious Diseases and Gene Expression in Insects
- Keywords
- advanced therapy medicinal products, automated cell culture, aseptic processing, microbial contamination, induced pluripotent stem cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review