The DOI matches its Crossref record; 49 of the 52 references it cites were found in a registry or an index, and 3 are not checked yet.
Techno-economic and environmental evaluation of a campus-scale floating photovoltaic system in Burdur, Türkiye
Open accessAbstract
This study presents a techno-economic and environmental evaluation of a campus-scale floating photovoltaic (FPV) system proposed for the campus lake of Burdur Mehmet Akif Ersoy University in Burdur, Türkiye. The assessment integrates lake-surface utilization, site-specific solar-resource conditions, actual campus electricity demand, discounted life-cycle economic analysis, environmental assessment, deterministic sensitivity analysis, and multi-parameter Monte Carlo uncertainty analysis. The contribution of the study lies in integrating site-specific FPV sizing and actual campus electricity-demand matching with discounted life-cycle economic analysis, environmental assessment, deterministic sensitivity analysis, and multi-parameter Monte Carlo uncertainty analysis within a single assessment framework. A total lake area of 12,000 m² is considered, with 40% allocated to FPV deployment. Using 580 W crystalline-silicon modules, 3,000 h/year of solar duration, and a performance ratio of 0.80, the proposed 1.08 MW system is estimated to generate approximately 2,592 MWh/year, corresponding to nearly 30% of annual campus electricity demand. Under the harmonized 25-year life-cycle assumptions, including 0.5% annual energy degradation, 2% annual O&M escalation, an inverter replacement in year 15, and an 8% discount rate, the discounted LCOE is approximately 0.0745 USD/kWh, the NPV is approximately 0.68 million USD, the IRR is approximately 12.91%, and the discounted payback period is approximately 10.97 years. A 10,000-run Monte Carlo analysis yields a positive NPV in approximately 97.5% of simulations. The system could also avoid approximately 1,166 tCO₂/year under the adopted grid-emission factor. The results support FPV as a promising campus-scale option while emphasizing that detailed PV simulation, engineering design, and site-specific ecological monitoring are required before implementation.
Verification finished with gaps
Some checks didn’t finish. The results below cover the steps that did.
- Registry recordVerified
- Full textRead the full text
- Reference list49 references found
- Reference check49 of 52 references checked · 3 not checked yet
- StatisticsRecomputed
- ClaimsDidn’t finish — the rest of the report still applies.
- Cited sourcesDidn’t finish — the rest of the report still applies.
- Self-checkChecked
- VerificationFindings verified
Overview
CoChat Summary
TL;DR
This paper presents an integrated feasibility assessment of a 1.08 MW floating photovoltaic (FPV) system on the campus lake of Burdur Mehmet Akif Ersoy University in Türkiye, combining system sizing, campus demand matching, discounted life-cycle economics, carbon accounting, and sensitivity/Monte Carlo uncertainty analysis. Under base-case assumptions the system generates 2,592 MWh/year (≈30% of campus demand) with an LCOE of 0.0745 USD/kWh and a positive NPV of +0.68 million USD.
Key findings
- A 40% lake-surface coverage scenario (4,800 m² of a 12,000 m² lake, 1,860 modules at 580 W each) yields 1.08 MW installed capacity and 2,592 MWh/year, covering 30.0% of the 8,640 MWh/year campus demand; 50% coverage would give 3,240 MWh/year (37.5%) and a theoretical 100% coverage 6,480 MWh/year (75.0%), which still would not provide annual energy autonomy.
- Base-case economics: CAPEX 1.62 million USD (1,500 USD/kW), annual O&M 24,300 USD (1.5% of CAPEX), annual revenue 259,200 USD at 0.10 USD/kWh, net annual profit 234,900 USD, discounted LCOE 0.0745 USD/kWh, NPV +0.68 million USD, IRR 12.91%, simple payback 7.06 years, discounted payback 10.97 years.
- Monte Carlo analysis (10,000 simulations, triangular distributions) gave a median NPV of 0.59 million USD (5th–95th percentile 0.09–1.14 million), a ~97.5% probability of positive NPV, median LCOE 0.0769 USD/kWh, and median simple/discounted paybacks of 7.15 and 11.57 years; electricity price (Pearson 0.66) was the strongest positive NPV driver, while CAPEX (−0.52) and discount rate (−0.48) were the strongest negative drivers.
- Environmental: using an assumed grid emission factor of 0.45 kgCO₂/kWh, the system avoids approximately 1,166 tCO₂/year, or 29,160 tCO₂ over the 25-year project life. Solar-resource stress tests showed negative NPV at 1,500 h/year (−0.65 million USD, 18.79-year payback) and 2,000 h/year (−0.21 million USD, 11.46-year payback), versus +0.68 million USD at the site-relevant 3,000 h/year.
Methods
- Site-specific feasibility study of a conceptual modular pontoon-based FPV array with crystalline-silicon modules and near-shore/shore-based anchoring on a 200 m × 60 m campus lake (12,000 m²) at Burdur Mehmet Akif Ersoy University (37.7144° N, 30.2715° E; ~32,000 students).
- Campus load data from CK Akdeniz Electricity Distribution Company: peak load 2,189.53 kW, minimum 798.21 kW, ~34 MWh daily consumption, 8,640 MWh/year annual demand; energy yield computed as installed capacity × annual solar duration (3,000 h/year from GEPA) × performance ratio (0.80).
- Economic analysis used a 25-year discounted cash-flow model with 8% discount rate, 0.5%/year module degradation, 2%/year O&M escalation, and a year-15 inverter replacement at 10% of CAPEX; supplemented by one-factor sensitivity analyses (electricity price 0.08–0.12 USD/kWh, CAPEX 1,200–1,800 USD/kW, O&M 1.0–2.0%, discount rate 6–10%, solar duration 1,500–3,000 h) and a 10,000-run multi-parameter Monte Carlo simulation with triangular input distributions.
Limitations
- Stated by the authors: the system has not been installed and the technical assessment is not validated against measured generation data or detailed FPV simulation; feasibility-level assumptions are used for solar duration, PR, CAPEX, electricity value, and the grid emission factor; structural, hydrodynamic, bathymetric, anchoring/mooring, electrical, protection, cable-routing, and grid-integration studies are out of scope; surface-albedo effects and tilt-angle optimization are discussed but not modeled, and no site-specific cooling gain is applied to base-case output; the quantitative environmental result is limited to avoided CO₂, with evaporation, water quality, ecosystem, and biodiversity effects drawn from literature rather than campus-lake measurements.
- Evident from the text: the 40% coverage ratio is a planning scenario, not an ecologically optimized or regulatory threshold (the paper notes Türkiye's 2024 legislation does not set a statutory coverage limit and that permitting must be confirmed); the model is area-proportional and linear, so it does not capture hourly generation–demand mismatch (campus peak occurs 17:00–20:00 when solar output declines), and storage is explicitly excluded from scope.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures











Verification
Claims the paper makes
This check didn’t finish.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Techno-Economic and Environmental Evaluation of a Campus-Scale Floating Photovoltaic System in Burdur, T ürkiye > 5. Discussion
“whereas changing CAPEX between 1,200 and 1,800 USD/kW results in payback periods ranging from approximately 5.5 to 8.3 years.”
§ Techno-Economic and Environmental Evaluation of a Campus-Scale Floating Photovoltaic System in Burdur, T ürkiye > 3.2. Sensitivity Analysis of the FPV System
“At 1,800 USD/kW, total investment rises to approximately 1.94 million USD and simple payback extends to 8.73 years.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Techno-Economic and Environmental Evaluation of a Campus-Scale Floating Photovoltaic System in Burdur, T ürkiye > 3.2.1. Multi-Parameter Monte Carlo Uncertainty Analysis
“Table 12.Monte Carlo Results for Key Economic Indicators (10,000 Simulations) Indicator 5th percentile Median 95th percentile NPV (million USD) +0.68 0.591 1.136”
§ Techno-Economic and Environmental Evaluation of a Campus-Scale Floating Photovoltaic System in Burdur, T ürkiye > 3.2.1. Multi-Parameter Monte Carlo Uncertainty Analysis
“Across the 10,000 simulations, the median NPV is approximately 0.59 million USD and the 5th-95th percentile interval ranges from 0.09 to 1.14 million USD.”
Citations
Cites
A review of the global climate change impacts, adaptation, and sustainable mitigation measures
Abbass, K., Qasim, M. Z., Song, H., Murshed, M., Mahmood, H., & Younis, I. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-19718-6 · Cited by 2,359
Strategies for mitigation of climate change: a review
Fawzy, S., Osman, A. I., Doran, J., & Rooney, D. W. (2020) · Environmental Chemistry Letters · doi:10.1007/s10311-020-01059-w · Cited by 1,522
Floating photovoltaic power plant: A review
Sahu, A., Yadav, N., & Sudhakar, K. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.08.051 · Cited by 878
Environmental impacts from the installation and operation of large-scale solar power plants
Turney, D., & Fthenakis, V. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.04.023 · Cited by 492
A review of floating photovoltaic installations: 2007–2013
Trapani, K., & Santafé, M. R. (2014) · Progress in Photovoltaics Research and Applications · doi:10.1002/pip.2466 · Cited by 437
Gorjian, S., Sharon, H., Ebadi, H., Kant, K., Scavo, F. B., & Tina, G. M. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.124285 · Cited by 386
Taormina, B., Bald, J., Want, A., Thouzeau, G., Lejart, M., Desroy, N., & Carlier, A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.07.026 · Cited by 333
Field experience and performance analysis of floating PV technologies in the tropics
Liu, H., Krishna, V., Lun Leung, J., Reindl, T., & Zhao, L. (2018) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.3039 · Cited by 306
Lee, N., Grunwald, B., Rosenlieb, E., Mirletz, H. M., Aznar, A., Spencer, R. S., & Cox, S. (2020) · Renewable Energy · doi:10.1016/j.renene.2020.08.080 · Cited by 276
Key issues in the design of floating photovoltaic structures for the marine environment
Claus, R., & López, M. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112502 · Cited by 237
Research works printed but not linked: 2
- Richter, 2017, Technical assumptions used in pv financial models: review of current practices and recommendations, IEA PVPS Task, 13
- Navigant Consulting, Inc. (2006). Review of PV Inverter Technology Cost and Performance Projections. National Renewable Energy Laboratory, NREL/SR-620-38771.
Cited by
Still being checked.
Metadata
- Authors
- Dursun, B., Aykut, E., Görgülü, S., & Dursun, S. Ü.
- Affiliations
- İstanbul Gelişim Üniversitesi (TR)
- Burdur Mehmet Akif Ersoy Üniversitesi (TR)
- Corresponding author
- Aykut, Ercan
- Venue
- Results in Engineering
- Publisher
- Elsevier BV
- Published
- 2026-12
- Volume
- 32
- Pages
- 112883
- ISSN
- 2590-1230 (ISSN-L)
- OpenAlex
- W7211878109
- Semantic Scholar
- aec9cf0e52be07d468c8232f9e8394b8f11a00fd
- Cited by
- 0
- References
- 49
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Locations
- Results in Engineering (publishedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Photovoltaic Systems and Sustainability
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Photovoltaic System Optimization Techniques
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Solar Thermal and Photovoltaic Systems
- Keywords
- floating photovoltaics, Monte Carlo uncertainty analysis, sensitivity analysis, CO2 emission reduction, crystalline silicon modules
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Techno-economic and environmental evaluation of a campus-scale floating photovoltaic system in Burdur, Türkiye. https://app.cochat.ai/papers/10.1016/j.rineng.2026.112883
- The paper
- Dursun, B., Aykut, E., Görgülü, S., & Dursun, S. Ü. (2026). Techno-economic and environmental evaluation of a campus-scale floating photovoltaic system in Burdur, Türkiye. Results in Engineering. https://doi.org/10.1016/j.rineng.2026.112883
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.