A review of frosting in air-to-air energy exchangers
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As the frost layer thickens, the efficiency of ASHP can drop by 35-60%.
“As the frost layer thickens, the efficiency of ASHP can drop by 35 -60 % [31 -34]”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [33]
Frosting causes blocked airflow passage, surge in pressure drop, and increased power consumption, which eventually degrade thermal performance.
“Nasr et al. [2] reviewed the various disadvantages of frosting, such as blocked airflow passage, surge in pressure drop and increased power consumption, which eventually degrade the thermal performance of the equipment.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Nasr et al. [2]
Frost formation on heat exchanger surfaces degrades thermal performance and may physically damage equipment.
“When such a unit is operated, frost is formed on the surface of the heat exchanger, which degrades thermal performance and may physically damage the equipment.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Nasr et al. [2]
Cites
<i>Review Article:</i> A Critical Review of Properties and Models for Frost Formation Analysis
Iragorry, J., Tao, Y.-X., & Jia, S. (2004) · HVAC&R Research · doi:10.1080/10789669.2004.10391111 · Cited by 89 · see citing works
Modeling non-uniform frost growth on a fin-and-tube heat exchanger
Padhmanabhan, S. K., Fisher, D. E., Cremaschi, L., & Moallem, E. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.06.005 · Cited by 66 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384 · see citing works
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218 · see citing works
Condensation frosting and passive anti-frosting
Yang, S., Wu, C., Zhao, G., Sun, J., Yao, X., Ma, X., & Wang, Z. (2021) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2021.100474 · Cited by 92 · see citing works
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Dynamic Defrosting on Superhydrophobic and Biphilic Surfaces
Gurumukhi, Y., Chavan, S., Sett, S., Boyina, K., Ramesh, S., Sokalski, P., Fortelka, K., Lira, M., Park, D., Chen, J.-Y., et al. (2020) · Matter · doi:10.1016/j.matt.2020.06.029 · Cited by 73 · see citing works
Experimental and numerical investigations of frost formation on wavy plates
Ma, Q., Wu, X., Chu, F., & Zhu, B. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.04.098 · Cited by 56 · see citing works
Hu, Y., Yuill, D. P., & Ebrahimifakhar, A. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.119423 · Cited by 39 · see citing works
Frosting in heat pump evaporators part A: experimental investigation
Reichl, C., Sandström, C., Hochwallner, F., Linhardt, F., Popovac, M., & Emhofer, J. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117487 · Cited by 34 · see citing works
Chen, G., Deng, X., Zhang, G., & Yan, X. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.12.133 · Cited by 31 · see citing works
Frosting in a heat pump evaporator part B: Numerical analysis
Popovac, M., Emhofer, J., & Reichl, C. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117488 · Cited by 26 · see citing works
Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification
He, H., Zhou, X., Lyu, N., Wang, F., Liang, C., & Zhang, X. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122914 · Cited by 19 · see citing works
Condensate drainage on slit or louvered fins in microchannel heat exchangers for anti-frosting
Sheng, W., Li, X., Wang, R., Dang, C., & Song, M. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110215 · Cited by 16 · see citing works
- Authors
- Rafati Nasr, M., Fauchoux, M., Besant, R. W., & Simonson, C. J.
- Affiliations
- University of Saskatchewan (CA)
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2014-02
- Volume
- 30
- Pages
- 538-554
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2013520468
- Cited by
- 191
- References
- 2
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 18 · 2023: 16 · 2022: 18 · 2021: 15 · 2020: 19 · 2019: 14 · 2018: 22 · 2017: 13 · 2016: 13 · 2015: 18 · 2014: 1
- FWCI
- 14.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Renewable and Sustainable Energy Reviews (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Keywords
- frost formation, air-to-air heat exchanger, frost protection, heat and moisture transfer, building heating and cooling systems, cold climate, energy conservation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review