Natural light controls and guides in buildings. Energy saving for electrical lighting, reduction of cooling load
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The residential sector is responsible for approximately a quarter of energy consumption in Europe. This consumption, together with that of other buildings, mainly from the tertiary sector, makes up 40% of total energy consumption and 36% of CO2 emissions. Artificial lighting makes up 14% of electrical consumption in the European Union and 19% worldwide. Through the use of well-designed natural lighting, controlled by technologies or systems which guarantee accessibility from all areas inside buildings, energy consumption for lighting and air conditioning can be kept to a minimum. The authors of this article carried out a state of the art on the technologies or control systems of natural light in buildings, concentrating on those control methods which not only protect the occupants from direct solar glare but also maximize natural light penetration in buildings based on the occupants׳ preferences, whilst allowing for a reduction in electrical consumption for lighting and cooling. All of the control and/or natural light guidance systems and/or strategies guarantee the penetration of daylight into the building, thus reducing the electrical energy consumption for lighting and cooling. At the same time they improve the thermal and visual comfort of the users of the buildings. However various studies have also brought to light certain disadvantages to these systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649
Guidelines for systematic review in Conservation and environmental management
PULLIN, A. S., & STEWART, G. B. (2006) · Conservation Biology · doi:10.1111/j.1523-1739.2006.00485.x · Cited by 1,137 · cited 1×
“The methodology used for this systematic review is described in [44,45], and consists of the following steps:”
MethodValidation of dynamic RADIANCE-based daylight simulations for a test office with external blinds
Reinhart, C. F., & Walkenhorst, O. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(01)00058-5 · Cited by 730
The impact of shading design and control on building cooling and lighting demand
Tzempelikos, A., & Athienitis, A. K. (2007) · Solar Energy · doi:10.1016/j.solener.2006.06.015 · Cited by 627
Effect of louver shading devices on building energy requirements
Palmero-Marrero, A. I., & Oliveira, A. C. (2010) · Applied Energy · doi:10.1016/j.apenergy.2009.11.020 · Cited by 275
Considerations for lighting in the built environment: Non-visual effects of light
Webb, A. R. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2006.03.004 · Cited by 240 · cited 1×
“Therefore, through a well-designed, controlled use of natural light, employing technologies or systems which ensure the penetration of light throughout the whole building, energy consumption designated to lighting and air conditioning can be kept at a minimum [23–35].”
BackgroundLighting energy savings in offices using different control systems and their real consumption
Roisin, B., Bodart, M., Deneyer, A., & D’Herdt, P. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.04.006 · Cited by 237 · cited 1×
“Better thermal efficiency and higher natural light penetration leading to savings in both cooling loads and lighting energy [93,95,106,116].”
BackgroundHaq, M. A. U., Hassan, M. Y., Abdullah, H., Rahman, H. A., Abdullah, M. P., Hussin, F., & Said, D. M. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.01.090 · Cited by 229 · cited 2×
“[1 36 ]”
BackgroundThe energy savings potential of using dynamic external louvers in an office building
Hammad, F., & Abu-Hijleh, B. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.05.024 · Cited by 213 · cited 4×
“Better thermal efficiency and higher natural light penetration leading to savings in both cooling loads and lighting energy [93,95,106,116].”
BackgroundInfluentialAn innovative lighting controller integrated in a self-adaptive building control system
Guillemin, A., & Morel, N. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00100-6 · Cited by 208
Comparing European residential building stocks: performance, renovation and policy opportunities
Meijer, F., Itard, L., & Sunikka-Blank, M. (2009) · Building Research & Information · doi:10.1080/09613210903189376 · Cited by 203 · cited 2×
“[1 36 ]”
BackgroundEnergy and visual comfort analysis of lighting and daylight control strategies
Shen, E., Hu, J., & Patel, M. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.04.028 · Cited by 201 · cited 1×
“[96], evaluated and compared the lighting, heating and cooling energy consumption, electric demand and visual comfort of different control strategies.”
BackgroundBateson, M. C. (2004) · PubMed Central · Cited by 200
Lee, E. S., DiBartolomeo, D. L., & Selkowitz, S. E. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(98)00035-8 · Cited by 197
Research and development on aspects of daylighting fundamentals
Alrubaih, M. S., Zain, M. F. M., Alghoul, M. A., Ibrahim, N., Shameri, M. A., & Elayeb, O. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.12.057 · Cited by 192 · cited 1×
“By acting on energy efficiency in buildings, it is possible to reduce energy consumption and therefore CO2 emissions into the atmosphere [11,12].”
BackgroundInoue, T., Kawase, T., Ibamoto, T., Takakusa, S., & Matsuo, Y. (1988) · ASHRAE winter conference papers · Cited by 185
Choi, J.-H., Beltran, L. O., & Kim, H.-S. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.10.010 · Cited by 184 · cited 1×
“Natural light significantly influences both the balance of energy use in buildings and actual human activity [14–17], offering the occupants comfort and health benefits, given that it plays an important biological role in the control of the physiological and psychological rhythms of living beings [18–20].”
BackgroundOffice worker response to an automated Venetian blind and electric lighting system: a pilot study
Vine, E., Lee, E. S., Clear, R. D., DiBartolomeo, D. L., & Selkowitz, S. E. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(98)00023-1 · Cited by 178 · cited 1×
“Natural light significantly influences both the balance of energy use in buildings and actual human activity [14–17], offering the occupants comfort and health benefits, given that it plays an important biological role in the control of the physiological and psychological rhythms of living beings [18–20].”
BackgroundXue, P., Mak, C. M., & Cheung, H. D. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.06.011 · Cited by 172 · cited 2×
“[1 37 ] E.”
BackgroundLighting and energy performance for an office using high frequency dimming controls
Li, D. H. W., Lam, T. N. T., & Wong, S. L. (2005) · Energy Conversion and Management · doi:10.1016/j.enconman.2005.06.016 · Cited by 168 · cited 1×
“Therefore, through a well-designed, controlled use of natural light, employing technologies or systems which ensure the penetration of light throughout the whole building, energy consumption designated to lighting and air conditioning can be kept at a minimum [23–35].”
BackgroundAutomated blind control to maximize the benefits of daylight in buildings
Koo, S. Y., Yeo, M.-S., & Kim, K. W. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.12.014 · Cited by 164 · cited 2×
“The solution to this problem lies in the use of automated blinds with an appropriate automated control system [102], which helps reach a balance between the right amount of natural light and maximum protection against overheating [94,95,97,105,113–115].”
MethodDaylighting and Human Performance
Heschong, L. (2002) · ASHRAE journal · Cited by 159
Efficient venetian blind control strategies considering daylight utilization and glare protection
Chan, Y.-C., & Tzempelikos, A. (2013) · Solar Energy · doi:10.1016/j.solener.2013.10.005 · Cited by 159 · cited 1×
“One disadvantage of louvres and blinds is that, if they are controlled manually by the occupants of a building, according to personal preferences, they often do not comply with the thermal, lighting and visual efficiency requirements [102–108].”
BackgroundDatta, G. (2001) · Renewable Energy · doi:10.1016/s0960-1481(00)00131-2 · Cited by 154
Athienitis, A. K., & Tzempelikos, A. (2002) · Solar Energy · doi:10.1016/s0038-092x(02)00016-6 · Cited by 148
Daylighting as a passive solar design strategy in tropical buildings: a case study of Malaysia
Zain-Ahmed, A., Sopian, K., Othman, M. Y., Sayigh, A., & Surendran, P. N. (2002) · Energy Conversion and Management · doi:10.1016/s0196-8904(01)00007-3 · Cited by 140 · cited 1×
“[46] presented a study on energy savings achieved through the use of daylight in passive solar building design.”
BackgroundOchoa, C. E., & Capeluto, I. G. (2005) · Building and Environment · doi:10.1016/j.buildenv.2005.05.001 · Cited by 139 · cited 4×
“[49]”
BackgroundInfluentialScartezzini, J., & Courret, G. (2002) · Solar Energy · doi:10.1016/s0038-092x(02)00040-3 · Cited by 135 · cited 2×
“Scartezzini and Courret [76] showed that on an overcast day, the daylight factor, measured at the back of a room, increased by 1.”
BackgroundEnergy Performance of Buildings: Energy Efficiency and Built Environment in Temperate Climates
Boemi, S.-N., Irulegi, O., & Santamouris, M. (2015) · Springer eBooks · doi:10.1007/978-3-319-20831-2 · Cited by 131
Evaluation of overheating protection with sun-shading systems
Kuhn, T. E., Bühler, C. M., & Platzer, W. J. (2001) · Solar Energy · doi:10.1016/s0038-092x(01)00017-2 · Cited by 129
Impact of window blinds on daylight-linked dimming and automatic on/off lighting controls
Galasiu, A. D., Atif, M. R., & MacDonald, R. A. (2004) · Solar Energy · doi:10.1016/j.solener.2003.12.007 · Cited by 127
Effect of daylight saving time on lighting energy use: A literature review
Aries, M. M., & Newsham, G. R. (2008) · Energy Policy · doi:10.1016/j.enpol.2007.05.021 · Cited by 119 · cited 1×
“Natural light significantly influences both the balance of energy use in buildings and actual human activity [14–17], offering the occupants comfort and health benefits, given that it plays an important biological role in the control of the physiological and psychological rhythms of living beings [18–20].”
BackgroundModelling light-pipe performances—a natural daylighting solution
Jenkins, D. P., & Muneer, T. (2003) · Building and Environment · doi:10.1016/s0360-1323(03)00061-1 · Cited by 114 · cited 1×
“Jenkins and Muneer [138–140] discussed numerous design models/methods to use in predicting light levels in light tubes, in other words, a tool to quantify the best configuration for light tubes in any given situation.”
BackgroundSelf-citationTzempelikos, A. (2008) · Solar Energy · doi:10.1016/j.solener.2008.05.014 · Cited by 110 · cited 1×
“Rotation angle, shape, size, configuration and color of slats all have an impact on glare and visibility, but also on effective transmittance, absorption and reflectance of a window-blind system [79].”
BackgroundChen, Y., Liu, J., Pei, J., Cao, X., Chen, Q., & Jiang, Y. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.01.030 · Cited by 104 · cited 1×
“Therefore, through a well-designed, controlled use of natural light, employing technologies or systems which ensure the penetration of light throughout the whole building, energy consumption designated to lighting and air conditioning can be kept at a minimum [23–35].”
BackgroundChronobiological aspects of green buildings daylighting
Hraška, J. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.06.008 · Cited by 93 · cited 1×
“The European Committee for Standardization will prepare the first European Code for daylighting in buildings and to define metrics for daylight and sunlight in all regularly occupied indoor spaces [42].”
BackgroundEnhanced policies for the improvement of electricity efficiencies
Blok, K. (2004) · Energy Policy · doi:10.1016/j.enpol.2004.02.006 · Cited by 91
The effect of window shading design on occupant use of blinds and electric lighting
Sanati, L., & Utzinger, M. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.013 · Cited by 90 · cited 2×
“In this way Sanati and Utzinger [51] showed that spaces where the windows had been fitted with light shelves used less electricity for lighting than those with conventional windows.”
BackgroundAn experimental study on the environmental performance of the automated blind in summer
Kim, J.-H., Park, Y., Yeo, M.-S., & Kim, K.-W. (2008) · Building and Environment · doi:10.1016/j.buildenv.2008.08.006 · Cited by 90 · cited 1×
“[120]”
Oh, M. H., Lee, K. H., & Yoon, J.-H. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.09.019 · Cited by 88
Pfrommer, P., Lomas, K. J., & Kupke, C. (1996) · Solar Energy · doi:10.1016/s0038-092x(96)00063-1 · Cited by 84 · cited 1×
“Much of the research carried out on louvres and blinds concentrates on calculating their optical properties and other questions relating to their control, employing experimental techniques [80–82], analytical models [83–85], semi-analytical and numerical methods [86–89] and ray-tracing simulation [90–92].”
MethodKuhn, T. E. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2005.10.002 · Cited by 82
Simmler, H., & Binder, B. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.10.011 · Cited by 77 · cited 1×
“Much of the research carried out on louvres and blinds concentrates on calculating their optical properties and other questions relating to their control, employing experimental techniques [80–82], analytical models [83–85], semi-analytical and numerical methods [86–89] and ray-tracing simulation [90–92].”
MethodBeverley, C. (2004) · Health Information & Libraries Journal · doi:10.1111/j.1471-1842.2004.00528.x · Cited by 72
U.S. energy savings potential from dynamic daylighting control glazings
Shehabi, A., DeForest, N., McNeil, A., Masanet, E. R., Greenblatt, J. B., Lee, E. S., Masson, G., Helms, B. A., & Milliron, D. J. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.07.013 · Cited by 70 · cited 2×
“[64]”
BackgroundLee, E. S., & Selkowitz, S. E. (1995) · Lawrence Berkeley National Laboratory · doi:10.2172/1416948 · Cited by 69 · cited 1×
“Therefore, through a well-designed, controlled use of natural light, employing technologies or systems which ensure the penetration of light throughout the whole building, energy consumption designated to lighting and air conditioning can be kept at a minimum [23–35].”
BackgroundAndersen, M., Rubín, M., Powles, R. C., & Scartezzini, J. (2004) · Solar Energy · doi:10.1016/j.solener.2004.06.005 · Cited by 68
Workplane illuminance prediction method for daylighting control systems
Park, K., & Athienitis, A. K. (2003) · Solar Energy · doi:10.1016/j.solener.2003.08.013 · Cited by 58
Chel, A. L., Tiwari, G. N., & Chandra, A. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.03.004 · Cited by 52 · cited 1×
“[131]”
Assessment of approaches for modeling louver shading devices in building energy simulation programs
Saelens, D., Parys, W., Roofthooft, J., & Tablada, A. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.10.056 · Cited by 45
Modelling the optical and thermal properties of complex glazing: overview of recent developments
Rosenfeld, J. L. J., Platzer, W. J., van Dijk, H., & Maccari, A. (2001) · Solar Energy · doi:10.1016/s0038-092x(01)00028-7 · Cited by 45
Methods for Calculating the Effective Longwave Radiative Properties of a Venetian Blind Layer
Yahoda, D. S., & Wright, J. L. (2004) · UWSpace (University of Waterloo) · Cited by 39
A glazing unit for solar control, daylighting and energy conservation
Lorenz, W. (2001) · Solar Energy · doi:10.1016/s0038-092x(00)00132-8 · Cited by 35 · cited 2×
“Lorenz [61] proved that this heightened penetration and uniformity of light reduces electrical energy consumption for cooling as it offers a significant improvement in the thermal comfort of the users during the summer months.”
BackgroundStrategies to control daylight in a responsive skylight system
Henriques, G. C., Duarte, J. P., & Leal, V. (2012) · Automation in Construction · doi:10.1016/j.autcon.2012.06.002 · Cited by 33 · cited 1×
“[126] developed a skylight system which responded to the environmental demands of a building's exterior as well as its interior.”
BackgroundSeasonal shading of vertical south-facades with prismatic panes
Christoffers, D. (1996) · Solar Energy · doi:10.1016/s0038-092x(96)00112-0 · Cited by 33 · cited 1×
“Along these lines, Christoffers [62] managed to reduce electrical energy consumption for cooling and heating by decreasing the direct solar radiation falling onto the front of a building by 10% in the summer whilst transmitting 90% of this radiation in winter.”
BackgroundDarula, S., Kocifaj, M., & Mohelníková, J. (2013) · Optik · doi:10.1016/j.ijleo.2012.09.052 · Cited by 27 · cited 1×
“[134].”
Impact of daylight quality on architectural space dynamics
Hourani, M. M., & Hammad, R. N. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.074 · Cited by 21
Simplified Solar Optical Calculations For Windows With Venetian Blinds
Wright, J. L., & Kotey, N. A. (2006) · UWSpace (University of Waterloo) · Cited by 17
Cited by
Cao, X., Dai, X., & Liu, J. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.06.089 · Cited by 1,436
Rezaei, S. D., Shannigrahi, S., & Ramakrishna, S. (2017) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2016.08.026 · Cited by 459
Ghosh, A., & Norton, B. (2018) · Renewable Energy · doi:10.1016/j.renene.2018.04.038 · Cited by 196
Pathirana, S., Rodrigo, A., & Halwatura, R. (2019) · International Journal of Energy and Environmental Engineering · doi:10.1007/s40095-018-0295-3 · Cited by 165
Metadata
- Authors
- Gago, E. J., Muneer, T., Knez, M., & Köster, H.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 41
- Pages
- 1-13
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2083762232
- Cited by
- 204
- References
- 58
- FWCI
- 15.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.