The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
A review on desiccant based evaporative cooling systems
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Removing latent heat from indoor environments through dehumidification is an essential and important method, especially in hot and humid climates, to reduce cooling load and increase human comfort [251].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [251]
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Energy Information Administration
(2007) · Choice Reviews Online · doi:10.5860/choice.44-3624 · Cited by 2,490
Demographic trends and energy consumption in European Union Nations, 1960–2025
York, R. (2007) · Social Science Research · doi:10.1016/j.ssresearch.2006.06.007 · Cited by 440
An experimental study of a novel dew point evaporative cooling system
Riangvilaikul, B., & Kumar, S. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.10.034 · Cited by 413
Zhan, C., Duan, Z., Zhao, X., Smith, S., Jin, H., & Riffat, S. (2011) · Energy · doi:10.1016/j.energy.2011.10.019 · Cited by 245
Heidarinejad, G., Bozorgmehr, M., Delfani, S., & Esmaeelian, J. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.017 · Cited by 235
Numerical study of a novel counter-flow heat and mass exchanger for dew point evaporative cooling
Zhao, X., Li, J. M., & Riffat, S. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2007.12.006 · Cited by 231
Numerical study of a novel dew point evaporative cooling system
Riangvilaikul, B., & Kumar, S. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.07.020 · Cited by 227
Jones, W. P. (2007) · Routledge eBooks · doi:10.4324/9780080498942 · Cited by 220
Evaporative Air Conditioning Handbook
Watt, J. R. (1986) · Springer eBooks · doi:10.1007/978-1-4613-2259-7 · Cited by 209
Research works printed but not linked: 21
- Ameen A. The challenges of air-conditioning in tropical and humid tropical climates. In: Proceedings of the international conference on mechanical engineering (ICME2005), Dhaka, Bangladesh; 2005.
- Heidarinejad, 2009, Experimental investigation of two-stage indirect/direct evaporative cooling system in various climatic conditions, Build Environ, 44, 2073, 10.1016/j.buildenv.2009.02.017 · DOI
- Kulkarni, 2001, Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage, Int J Appl Eng, 1, 800
- Enteria, 2011, The role of the thermally activated desiccant cooling technologies in the issue of energy and environment, Renewable Sustainanle Energy Rev., 15, 2095, 10.1016/j.rser.2011.01.013 · DOI
- Dezfouli MMS, Mat S, Sopian K. Comparison simulation between ventilation and recirculation of solar desiccant cooling system by TRNSYS in hot and humid area. In: Proceedings of the seventh international conference on renewable energy sources, Kuala Lumpur, Malaysia, ISBN:978-1-61804-175-3; 2013.
- Haddad K, Ouazia B, Barhoun H. Simulation of a desiccant-evaporative cooling system for residential buildings. In: Third Canadian solar buildings conference, Fredericton, N.B.; 2008; p. 1–8.
- Parmar, 2010, Performance of a solid desiccant based evaporative cooling system in warm and humid climatic zone of India, Int J Eng Sci Technol, 2, 5504
- Wurtz E, Maalouf C, Mora L, Allard F. Parametric analysis of a solar desiccant cooling system using the SimSPARK Environment. In: Ninth international IBPSA conference Montréal, Canada; 2005. p. 15–18.
- Ouazia B, Barhoun H, Barhoun H, Haddad K, Armstrong MM, Marchand RG, Szadkowski F. Desiccant-evaporative cooling system for residential buildings. In: 12th Canadian conference on building science and technology Montréal, Québec; 2009.
- Saman, 2002, An experimental study of a cross-flow type plate heat exchanger for dehumidification/cooling, Sol Energy, 73, 59, 10.1016/S0038-092X(01)00078-0 · DOI
- Camargo JR, Ebinuma CD, Cardoso S. A mathematical model for direct and indirect evaporative cooling air conditioning systems. In: Proceedings of the ninth Brazilian congress of thermal engineering and sciences, ENCIT, UFPB, PB, paper CIT02-0855; 2002.
- Worek, 1991, Simulation of advanced gas-fired desiccant systems, ASHRAE Trans, 97, 609
- Eskra, 1980, Indirect–direct evaporative cooling systems, ASHRAE J, 22, 21
- Kulkarni, 2011, Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage, Int. J. Appl. Eng. Res., 1.4, 800
- Maclaine-Cross, 1981, A general theory of wet surface heat exchangers and its application to regenerative evaporative cooling, J Heat Transf -Trans Asme—J Heat Transf, 103, 579, 10.1115/1.3244505 · DOI
- Yellott, 1984, Indirect evaporative air coolers for hot, dry climates, ASHRAE Trans, 90, 139
- Eskra, 1980, Indirect/direct evaporative cooling systems, ASHRAE J., 22, 21
- Crum DR. Open cycle air conditioning systems. MS thesis, Wisconsin–Madison, USA; 1986.
- Bisoniya, 2011, Comparative thermal analysis of theoretical and experimental studies of modified indirect evaporative cooler having cross flow heat exchanger with one fluid mixed and the other unmixed, Int J Energy Environ, 2, 921
- Jose, 1998, Simulation model of an indirect evaporative cooler, Energy Build, 29, 23, 10.1016/S0378-7788(98)00014-0 · DOI
- SWEEP/WCEC. SWEEP/WCEC Workshop on modern evaporative cooling technologies, Boulder, CO; September 14, 2007.
Cited by
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Metadata
- Authors
- Mujahid Rafique, M., Gandhidasan, P., Rehman, S., & Al-Hadhrami, L. M.
- Affiliations
- King Fahd University of Petroleum and Minerals (SA)
- Corresponding author
- Gandhidasan, P.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 45
- Pages
- 145-159
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2000826176
- Cited by
- 227
- References
- 77
- Citations by year
- 2026: 12 · 2025: 19 · 2024: 15 · 2023: 18 · 2022: 26 · 2021: 30 · 2020: 28 · 2019: 15 · 2018: 22 · 2017: 19 · 2016: 18 · 2015: 5
- FWCI
- 20.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Renewable and Sustainable Energy Reviews (publishedVersion)
- Funders
- National Plan for Science, Technology and Innovation
- King Abdulaziz City for Science and Technology
- King Fahd University of Petroleum and Minerals (10-ENE1372-04)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Solar-Powered Water Purification Methods
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- evaporative coolers, latent load, air conditioning, solar cooling, thermal energy utilization, hot and humid climate, thermal comfort, energy consumption reduction, CO2 emission reduction, system configuration, operating modes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review on desiccant based evaporative cooling systems. https://app.cochat.ai/papers/10.1016/j.rser.2015.01.051
- The paper
- Mujahid Rafique, M., Gandhidasan, P., Rehman, S., & Al-Hadhrami, L. M. (2015). A review on desiccant based evaporative cooling systems. Renewable and Sustainable Energy Reviews. https://doi.org/10.1016/j.rser.2015.01.051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.