The DOI matches its Crossref record.
A review on windcatcher for passive cooling and natural ventilation in buildings, Part 1: Indoor air quality and thermal comfort assessment
Open accessAbstract
The most prominent challenge in 21th century is global warming which seriously threats the mankind. Building sector with 40% of global energy consumption and GHG emission play a key role in this threat. In this regard, the impact of cooling systems cannot be ignored where along with ventilation and heating systems totally account for 60% of energy consumed in buildings. Passive cooling systems can be a promising alternative to reduce energy consumption. One of the oldest passive cooling system that is still being used today is windcatcher. By manipulating pressure differences and the buoyancy effect, an adequate level of ventilation in buildings can be provided by windcatchers. Since most of the previous windcatcher studies assessed the design characteristics, the current investigation focused on the indoor air quality (IAQ) and thermal comfort aspects. The review details and compares the different theoretical and experimental methods employed by researchers in different case studies to assess the IAQ and thermal comfort. It was found that most IAQ studies were conducted in the UK using CFD and experimental techniques. Previous studies assessed IAQ based on several parameters such as air flow rate, air change rate, CO2 concentration, air change effectiveness and mean age of air. The findings of the studies revealed that satisfactory IAQ were generally achieved using the windcatcher. On the other hand, thermal comfort studies of windcatchers were mainly conducted in hot climates such as in the Middle East. In addition to night ventilation, the review also looked into the different types of cooling methods incorporated with windcatchers such as evaporative cooling, earth to air heat exchangers (EAHE) and heat transfer devices (HTD). Night ventilation was found to be effective in temperate and cold conditions while additional cooling using evaporative cooling, EAHE and HTD were found to be necessary in hot climates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adsorption-based atmospheric water harvesting
Ejeian, M., & Wang, R. Z. (2021) · Joule · doi:10.1016/j.joule.2021.04.005 · Cited by 416
Bhamare, D. K., Rathod, M. K., & Banerjee, J. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.023 · Cited by 277
Ahmed, T., Kumar, P., & Mottet, L. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110669 · Cited by 270
Sun, K., Zhang, W., Zeng, Z., Levinson, R., Wei, M., & Hong, T. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111383 · Cited by 86
Qin, H., & Pan, W. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.120041 · Cited by 66
Metadata
- Authors
- Jomehzadeh, F., Nejat, P., Calautit, J. K., Yusof, M. B. M., Zaki, S. A., Hughes, B. R., & Yazid, M. N. A. W. M.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 70
- Pages
- 736-756
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2560795218
- Cited by
- 237
- References
- 0
- FWCI
- 15.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review on windcatcher for passive cooling and natural ventilation in buildings, Part 1: Indoor air quality and thermal comfort assessment. https://app.cochat.ai/papers/10.1016/j.rser.2016.11.254
- The paper
- Jomehzadeh, F., Nejat, P., Calautit, J. K., Yusof, M. B. M., Zaki, S. A., Hughes, B. R., & Yazid, M. N. A. W. M. (2017). A review on windcatcher for passive cooling and natural ventilation in buildings, Part 1: Indoor air quality and thermal comfort assessment. Renewable and Sustainable Energy Reviews. https://doi.org/10.1016/j.rser.2016.11.254
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.