A review of passive envelope measures for improved building energy efficiency in the UAE
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isaac, M., & van Vuuren, D. P. (2009) · Energy Policy · doi:10.1016/j.enpol.2008.09.051 · Cited by 1,166
Heating and cooling energy trends and drivers in buildings
Ürge-Vorsatz, D., Cabeza, L. F., Serrano, S., Barreneche, C., & Petrichenko, K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.08.039 · Cited by 1,089 · cited 1×
“Introduction The worldwide building sector consumed 32% of the global final energy in 2010, and was responsible for one-third of global CO2 emissions [1].”
BackgroundRadhi, H. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.04.006 · Cited by 299 · cited 4×
“Radhi [13], and in the context of UAE residential buildings, reports the possibility of similar savings (between 26.”
BackgroundInfluentialThe development of commercial wind towers for natural ventilation: A review
Hughes, B. R., Calautit, J. K., & Ghani, S. A. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.11.066 · Cited by 278 · cited 4×
“The wind tower takes advantage of the pressure differences generated by wind around a building, and generates a cross-flow in the building by positioning the inlet in a high pressure area, and the outlet in a low pressure area [39].”
BackgroundInfluentialResidential peak electricity demand response—Highlights of some behavioural issues
Gyamfi, S., Krumdieck, S., & Urmee, T. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.006 · Cited by 265 · cited 2×
“energy savings based on increasing the set point provides a sharp contrast to the expense and effort required to achieve similar savings using constructive measures [2].”
BackgroundTaleb, H. M. (2014) · Frontiers of Architectural Research · doi:10.1016/j.foar.2014.01.002 · Cited by 263 · cited 7×
“Taleb [31] includes a green roof as a passive cooling strategy in the performance model of a Dubai villa, however does not provide details on the type of green roof utilized or the specific performance improvement due to the green roof.”
BackgroundMethodInfluentialAl-Sanea, S. A., Zedan, M. F., & Al-Hussain, S. N. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.08.009 · Cited by 263 · cited 1×
“[29] have shown that increased thermal mass is beneficial by decreasing peak transmission loads, and by reducing heating transmission loads through the walls in particular during the moderate months.”
BackgroundThe energy savings potential of using dynamic external louvers in an office building
Hammad, F., & Abu-Hijleh, B. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.05.024 · Cited by 213 · cited 3×
“Hammad et al. [37] address the solar heat gain through glazing by incorporating dynamic external louvers as shading devices in an office building.”
BackgroundInfluentialAsif, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.05.042 · Cited by 193 · cited 1×
“The UAE’s extreme climate generates a challenging environment for energy conservation and environmental sustainability of buildings [4].”
BackgroundWall insulation measures for residential villas in Dubai: A case study in energy efficiency
Friess, W. A., Rakhshan, K., Hendawi, T. A., & Tajerzadeh, S. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.10.005 · Cited by 148 · cited 7×
“[12] similar study for a Dubai villa, which results in a decrease in cooling load of 29.”
BackgroundResultSelf-citationRecommendations on renewable energy policies for the GCC countries
Abdmouleh, Z., Alammari, R. A. M., & Gastli, A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.05.057 · Cited by 146 · cited 1×
“● The large-developer business model, where profit is maximized while keeping initial construction costs low [14] ● The artificially low cost of energy, reducing the perceived importance of operational cooling costs during the lifetime of the building ● The long time absence of any energy regulation forcing the implem…”
BackgroundKazim, A. M. (2005) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2005.01.008 · Cited by 137 · cited 2×
“These factors contribute to an average per-capita energy consumption that is nine times higher than the world’s average energy consumption, four times higher than the EU’s energy consumption, and two times higher than the US energy consumption [8].”
BackgroundExperimental study on reduced heat gain through green façades in a high heat load climate
Haggag, M., Hassan, A., & ELMASRY, S. K. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.087 · Cited by 127 · cited 2×
“[32] School Al Ain Introduction of green wall Reduction of external wall temperature by 5 ̊C to 13 ̊C during the day”
BackgroundPaths to a low-carbon economy—The Masdar example
Nader, S. (2009) · Energy Procedia · doi:10.1016/j.egypro.2009.02.199 · Cited by 122 · cited 1×
“The MASDAR development in Abu Dhabi represents a singular exponent of the application of best energetic practices at all levels, as the entire development is conceived with sustainability and energetic considerations as focal areas, however little quantitative experimental confirmation of the projected energetic savin…”
BackgroundSolar energy in the United Arab Emirates: A review
Mokri, A., Ali, M. A., & Emziane, M. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.07.038 · Cited by 120 · cited 6×
“[6] confirm these findings of very high irradiance.”
BackgroundResultInfluentialEzzeldin, S., & Rees, S. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.06.004 · Cited by 119 · cited 5×
“High-rise and mixed-use buildings generally rely on air conditioning year round to maintain appropriate indoor conditions, and do not include owner-operated or wind or stack effect driven ventilation (studies report that using passive natural ventilation in office buildings has been found to be insufficient in order t…”
BackgroundMethodInfluentialCourtyard housing in midrise buildings: An environmental assessment in hot-arid climate
Al-Masri, N., & Abu-Hijleh, B. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.01.008 · Cited by 116 · cited 9×
“Al Masri [24] presents a comprehensive computational parametric study on the integration of a courtyard into a typical Dubai mid-rise residential building, by quantifying energy savings due to the courtyard form, as well as the effect of increasing the wall thickness, various insulation materials, and increasing wall…”
BackgroundMethodInfluentialAl-Sanea, S. A., & Zedan, M. F. (2007) · Applied Energy · doi:10.1016/j.apenergy.2007.06.019 · Cited by 94 · cited 1×
“Further occupant-based measures Occupant behavior and interior set points play a critical role in energy conservation [47], and while they do not constitute a part of the building envelope, a number of the studies reported in this review include energy savings results based on a change of internal set point.”
ResultRadhi, H., Sharples, S., & Fikiry, F. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.08.030 · Cited by 91 · cited 2×
“[38] Al Ain University building (100% glazing) CFD and building energy simulation of impact of climate interactive façade systems 17% to 20% reduction in cooling energy”
BackgroundAboulNaga, M. M., & Abdrabboh, S. N. (2000) · Renewable Energy · doi:10.1016/s0960-1481(99)00014-2 · Cited by 79 · cited 3×
“The authors suggest that night time ventilation at this rate is sufficient to provide the required cooling for a heavy residential building [45].”
BackgroundOn the optimal selection of wall cladding system to reduce direct and indirect CO2 emissions
Radhi, H. (2010) · Energy · doi:10.1016/j.energy.2009.11.026 · Cited by 70 · cited 2×
“Radhi [30] 3 story academic building Al-Ain Changing wall cladding systems: Stucco, Masonry veneer, Aluminum siding, Vinyl siding, Exterior Insulation and Finish systems (EFIS) EUI is proportional to absorption coefficient: EFIS (abs.”
BackgroundAboulNaga, M. M. (1998) · Renewable Energy · doi:10.1016/s0960-1481(98)00090-1 · Cited by 64 · cited 2×
“Aboulnaga [44] presents a theoretical analysis of the optimum geometry of an inclined roof solar chimney with absorber plate coupled with an evaporative cooling cavity at the inlet in a two story residential building in Al Ain.”
BackgroundDesigning a sustainable house in the desert of Abu Dhabi
Al-Sallal, K. A., Al-Rais, L., & Dalmouk, M. M. B. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.01.061 · Cited by 56 · cited 9×
“[25] designed a sustainable house in the desert of Abu Dhabi using Estidama Guidelines and rating methods along with referring to other standards or less formal documents such as LEED Homes or Resolution 66 of Dubai Municipality (DM).”
BackgroundMethodInfluentialRakhshan, K., Friess, W. A., & Tajerzadeh, S. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.05.010 · Cited by 42 · cited 1×
“[28] examined the environmental impact of the increased insulation levels for the same villa, and report that the sustainability cost of adding the insulation is small in comparison to the operational energy savings and GHG emissions.”
BackgroundSelf-citationInvestigating the use of green design parameters in UAE construction projects
Gharzeldeen, M., & Beheiry, S. M. (2014) · International Journal of Sustainable Engineering · doi:10.1080/19397038.2014.895066 · Cited by 21 · cited 1×
“These regulations differ from Emirate to Emirate, and are slowly becoming mandatory, however their execution is only becoming enforceable as the development and certification of implementation professionals increases [17].”
BackgroundControl of natural ventilation for aerodynamic high-rise buildings
Sivakumar, P., Palanthandalam‐Madapusi, H. J., & Dang, T. Q. (2010) · Building Simulation · doi:10.1007/s12273-010-0014-3 · Cited by 8 · cited 1×
“(however, some departures to this model exist, and successfully leverage shape effects to improve natural ventilation [23]).”
Background
Cited by
Optical and thermal performance of glazing units containing PCM in buildings: a review
Li, D., Wu, Y., Wang, B., Liu, C., & Arıcı, M. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.117327 · Cited by 216
Barriers to Implementing the Circular Economy in the Construction Industry: A Critical Review
Charef, R., Morel, J.-C., & Rakhshan, K. (2021) · Sustainability · doi:10.3390/su132312989 · Cited by 188
Self-citationAlmasri, R. A., & Narayan, S. (2021) · International Journal of Green Energy · doi:10.1080/15435075.2021.1904941 · Cited by 62
Impact of the new Saudi energy conservation code on Saudi Arabia residential buildings
Alardhi, A., S Alaboodi, A., & Almasri, R. (2022) · Australian Journal of Mechanical Engineering · doi:10.1080/14484846.2020.1802919 · Cited by 34
Metadata
- Authors
- Friess, W. A., & Rakhshan, K.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 72
- Pages
- 485-496
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2578630486
- Cited by
- 184
- References
- 26
- FWCI
- 14.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.