Scrutinising embodied carbon in buildings: The next performance gap made manifest
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Life cycle assessment (LCA) is becoming increasingly mainstream as an early-stage design-decision tool for buildings. Still, there are considerable variations in how the method is currently used, leading to limitations in comparing the results and the conclusions that can be drawn. These variations are due to several factors and LCA modellers must make multiple methodological decisions during an assessment. This has resulted, unsurprisingly, in a variety of approaches, and a wide range of outcomes. Academics have produced numerous case studies on particular buildings, aiming towards a detailed understanding of the energy and carbon impacts. However, very few case studies are detailed enough to allow for an in-depth comparison. This article investigates in detail these embodied carbon assessments, considering the data used and the methodological assumptions made. An in-depth analysis shows that there are still considerable variations in how the methodology is applied, leading to substantial limitations in comparing results and drawing conclusions. Results may differ by two orders of magnitude, thus limiting the understanding of how real mitigation might best be achieved. Without immediate action, embodied carbon will become a ‘second wave’ of performance gap in environmental assessments of buildings. Both greater transparency and greater conformity must be embraced by the LCA community and enforced by policymakers and professional bodies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tranfield, D., Denyer, D., & Smart, P. (2003) · British Journal of Management · doi:10.1111/1467-8551.00375 · Cited by 15,386
Primary, Secondary, and Meta-Analysis of Research
GLASS, G. V. (1976) · Educational Researcher · doi:10.3102/0013189x005010003 · Cited by 4,890 · cited 1×
“This part of this research can be methodologically seen as ‘secondary analysis’ and ‘meta-analysis’ as defined by Glass [38].”
MethodLife cycle energy analysis of buildings: An overview
Ramesh, T., Prakash, R., & Shukla, K. K. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.05.007 · Cited by 1,408 · cited 2×
“Their work is also solely focused on energy, and not carbon, of buildings, and – similarly to Sartori and Hestnes [23] – they also found that operational energy accounts for 80–90% of the whole life energy, and that measures aimed at its reduction might be counterproductive from a whole life perspective [25].”
BackgroundEnergy use in the life cycle of conventional and low-energy buildings: A review article
Sartori, I., & Hestnes, A. G. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.07.001 · Cited by 1,284 · cited 4×
“Sartori and Hestnes [23] reviewed 60 cases from nine countries, and found a quasi-perfect linear correlation (i.e. an R2 coefficient close to 1) between operational energy and whole life energy, which was valid across climates and other contextual differences.”
BackgroundInfluentialEmbodied carbon mitigation and reduction in the built environment – What does the evidence say?
Pomponi, F., & Moncaster, A. (2016) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.08.036 · Cited by 483
Self-citationTechnological innovation, energy efficient design and the rebound effect
Herring, H., & Roy, R. (2007) · Technovation · doi:10.1016/j.technovation.2006.11.004 · Cited by 456 · cited 1×
“The application of the now well-known concept of the ‘rebound effect’ to the energy performance of buildings [3], later followed by the development of the idea of the ‘prebound effect’ [4], demonstrate the developing maturity of academic research in this area, which is helping the move towards increased actual reducti…”
BackgroundChau, C. K., Hui, W. K., Ng, W. Y., & Powell, G. (2012) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2012.01.001 · Cited by 160
Cited by
Buildings as a global carbon sink
Churkina, G., Organschi, A., Reyer, C. P. O., Ruff, A., Vinke, K., Liu, Z., Reck, B. K., Graedel, T. E., & Schellnhuber, H. J. (2020) · Nature Sustainability · doi:10.1038/s41893-019-0462-4 · Cited by 1,045
Building simulation: Ten challenges
Hong, T., Langevin, J., & Sun, K. (2018) · Building Simulation · doi:10.1007/s12273-018-0444-x · Cited by 234
“The performance gap is not only limited to energy and has recently been extended to other metrics such as embodied emissions (Pomponi and Moncaster 2018).”
BackgroundLife cycle assessment in the building design process – A systematic literature review
Roberts, M., Allen, S., & Coley, D. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107274 · Cited by 210
Cabeza, L. F., Boquera, L., Chàfer, M., & Vérez, D. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110612 · Cited by 175
“53 Nadoushani (2015) [130,131] Pomponi (2018) [11]”
BackgroundInfluential
Metadata
- Authors
- Pomponi, F., & Moncaster, A.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2018-01
- Volume
- 81
- Pages
- 2431-2442
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2655135839
- Cited by
- 231
- References
- 7
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.