CoChat

Active and passive cooling methods for dwellings: A review

Oropeza-Perez, Ivan, Østergaard, Poul Alberg · 2018 · Renewable and Sustainable Energy Reviews
Cited by 184

The DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.rser.2017.09.059

Cites

117 of 117 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 117 references

Research works printed but not linked: 88

  1. British Petroleum. Statistical Review of WorldEnergy. 2013; Available at: 〈http://www.bp.com〉. [Accessed March 2013].
  2. Kammerud, 1984, Ventilation cooling of residential buildings, ASHRAE Trans, 90, 226
  3. 2005, Evaluation of hydronic forced-air and radiant slab heating and cooling systems, ASHRAE Transactions, 1, 525
  4. Zhai Z. Numerical study of optimal building scales with low cooling load in both hot and mild climatic regions. American Solar Energy Society - Solar 2006: 35th ASES Annual Conf., 31st ASES National Passive Solar Conf., 1st ASES Policy and Marketing Conf., ASME Solar Energy Division Int. Solar Energy Conference, 3. 2006. p. 1516–21. · doi:10.1115/isec2006-99003
  5. Garai, 2009, Physical model for vaporization, Fluid Phase Equilib, 283, 89, 10.1016/j.fluid.2009.06.005 · doi:10.1016/j.fluid.2009.06.005
  6. Zhang D, Zhao W. Experimental study on simplified thermo-technical calculation for evaporative coolers. CCIE 2011 - Proceedings: 2011 IEEE 2nd International Conference on Computing, Control and Industrial Engineering, 1. 2011. p. 348–51.
  7. Al-Azzawi A, Almuhtadi W. Energy saving by using newly designed automated solar powered evaporative air cooler (ASPEAC). IEEE Electrical Power and Energy Conference, EPEC. 2009. · doi:10.1109/epec.2009.5420379
  8. Yuan, 2011, Optimizing energy consumption of a water-loop variable-speed heat pump system, Appl Therm Eng, 31, 894, 10.1016/j.applthermaleng.2010.11.012 · doi:10.1016/j.applthermaleng.2010.11.012
  9. Agnieszka, 2010, Absorption and adsorption chillers applied to air conditioning systems, Arch Thermodyn, 31, 77, 10.2478/v10173-010-0010-0 · doi:10.2478/v10173-010-0010-0
  10. Garcia-Gutierrez, 2010, Research and development on heat pump systems in Mexico using geothermal energy, Curr Appl Phys, 10, S123, 10.1016/j.cap.2009.11.016 · doi:10.1016/j.cap.2009.11.016
  11. Garcia-Gutierrez, 2007, Research on heat pumps in México operating on geothermal and waste energy as heat source, Trans - Geothermal Resources Council, 31, 471
  12. Balaras, 2003, Recent activities on solar air conditioning, ASHRAE Trans, 1, 251
  13. Sanjuan, 2010, Optimization of a solar cooling system with interior energy storage, Sol Energy, 84, 1244, 10.1016/j.solener.2010.04.001 · doi:10.1016/j.solener.2010.04.001
  14. Mueller HFO. Daylighting and solar control - A parameter study for office buildings. 22nd international conference, PLEA 2005: passive and low energy architecture - environmental sustainability: the challenge of awareness in developing societies, Proceedings, 1. 2005. p. 451–5.
  15. Schuster HG. The influence of daylight design in office buildings on the users comfort. PLEA2006 − 23rd international conference on passive and low energy architecture, conference proceedings. 2006. p. I447–52.
  16. Parys W, Saelens D, Hens H. Optimization of energy use for heating/cooling and lighting for a typical office building in a moderate climate. Proceedings − 6th international symposium on heating, ventilating and air conditioning, ISHVAC, 1; 2009. p. 168–75.
  17. Zhou, 2012, Review of thermal energy storage with phase change materials (PCMs) in building applications, Appl Energy, 92, 593, 10.1016/j.apenergy.2011.08.025 · DOI · Paper page
  18. Wishart AJ. Heat transfer design of shelters for rural electronic exchanges. INTELEC, International Telecommunications Energy Conference (Proceedings). 1986. p. 513–6. · doi:10.1109/intlec.1986.4794476
  19. Gianolio G, Rosso I, Mercante L, Pedrazzo F, Simonato G, Ceriani F. GreenShelter for telecom applications: A new generation of shelters for telecom applications integrating fuel cell electric backup and a new cooling approach. INTELEC, International Telecommunications Energy Conference (Proceedings). 2008. · doi:10.1109/intlec.2008.4664059
  20. Le Masson, 2012, Towards passive cooling solutions for mobile access network, Annal Telecommun/Ann Telecommun, 67, 125, 10.1007/s12243-011-0283-6 · doi:10.1007/s12243-011-0283-6
  21. Borge, 2011, Exergy efficiency analysis in buildings climatized with LiCl-H 2O solar cooling systems that use swimming pools as heat sinks, Energy Build, 43, 3161, 10.1016/j.enbuild.2011.08.014 · doi:10.1016/j.enbuild.2011.08.014
  22. Thompson JA, Gilbey MJ. Transient heat sink calculations for feasibility design studies. BHR Group − 14th International Symposium on Aerodynamics and Ventilation of Tunnels. 2011. p. 145–58.
  23. Sanusi, 2013, Passive ground cooling system for low energy buildings in Malaysia (hot and humid climates), Renew Energy, 49, 193, 10.1016/j.renene.2012.01.033 · doi:10.1016/j.renene.2012.01.033
  24. Onyango, 2012, Simulation of a passive ground-coupled cooling system for a room in a hot humid climate, WIT Trans Ecol Environ, 160, 257, 10.2495/DN120231 · doi:10.2495/dn120231
  25. Woodson, 2012, Earth-air heat exchangers for passive air conditioning: case study burkina faso, J Construct Dev Ctries, 17, 21
  26. Li, 2009, Experimental study of a ground sink direct cooling system in cold areas, Energy Build, 41, 1233, 10.1016/j.enbuild.2009.07.020 · doi:10.1016/j.enbuild.2009.07.020
  27. Li, 2009, Experimental study on ground temperature variation characteristics of a ground-sink direct cooling system, Harbin Gongye Daxue Xuebao/J Harbin Inst Technol, 41, 72
  28. Givoni, 2007, Cooled soil as a cooling source for buildings, Sol Energy, 81, 316, 10.1016/j.solener.2006.07.004 · doi:10.1016/j.solener.2006.07.004
  29. Hasan, 2013, Study the heat sink potential of building ground floor slab integrated with ELT, Appl Mech Mater, 268, 967
  30. Larsen SF, Filippín C, Lesino G. Buried pipes for air conditioning: Two cases of educational buildings in Argentina. Proceedings of the Solar World Congress: bringing water to the world, including proceedings of 34th ASES annual conference and proceedings of 30th national passive solar conference, 2. 2005. p. 1359–64.
  31. Angelotti A, Solaini G. Design guidelines for direct ground cooling systems in different climates. PLEA2006 − 23rd international conference on passive and low energy architecture, conference proceedings. 2006. p. II363-II368.
  32. Eicker, 2009, Potential of geothermal heat exchangers for office building climatisation, Renew Energy, 34, 1126, 10.1016/j.renene.2008.06.019 · doi:10.1016/j.renene.2008.06.019
  33. Imperadori M, Masera G, Iannaccone G, Dell'Oro D. Improving energy efficiency through artificial inertia: the use of Phase Change Materials in light, internal components. PLEA 2006 − 23rd International conference on passive and low energy architecture, conference proceedings. 2006. p. I547-52.
  34. Yang, 2012, Study on effect of thermal mass on thermal stability of building with solar air heating, Taiyangneng Xuebao/Acta Energiae Solaris Sin, 33, 1777
  35. Abdou, 1993, Thermal energy performance of load-bearing concrete masonry in residential buildings in hot, dry climates, Energy Sources, 15, 159, 10.1080/00908319308909021 · doi:10.1080/00908319308909021
  36. Kehrer M, Schmidt T. Radiation effects on exterior surfaces. Nordic symposium of building physics. Copenhagen. 2008.
  37. Naraghi, 2013, Configuration of building faade surface for seasonal selectiveness of solar irradiation-absorption and reflection, J Sol Energy Eng, Trans ASME, 135, 10.1115/1.4006673 · doi:10.1115/1.4006673
  38. Yacouby AMA, Khamidi MF, Nuruddin MF, Farhan SA, Razali AE. Study on roof tile's colors in Malaysia for development of new anti-warming roof tiles with higher Solar Reflectance Index (SRI). 2011 National Postgraduate Conference - Energy and Sustainability: Exploring the Innovative Minds, NPC 2011.
  39. Cocuzzi, 2004, Cool roofing: a really hot topic, JCT CoatingsTech, 1, 22
  40. Erell E, Yannas S, Molina JL. Roof cooling techniques. PLEA2006 − 23rd international conference on passive and low energy architecture, conference proceedings. 2006. p. II571–6.
  41. Teixeira CFB, Labaki LC, Tavares S. Studies of thermal behaviour of radiant cooling in tropical climate. 22nd international conference, PLEA 2005: passive and low energy architecture - environmental sustainability: the challenge of awareness in developing societies, proceedings, 1. 2005. p. 407–11.
  42. Parker, 1994, Measured residential cooling energy savings from reflective roof coatings in Florida, ASHRAE Trans, 100, 36
  43. Gartland L. Demonstrated energy savings of cool roof coatings and future directions for research. Interface (Raleigh, North Carolina), 15(11):8–10, 12, 14. 1997.
  44. De Graeve, 2011, The road to intelligent coloured coatings, Surf Eng, 27, 719, 10.1179/174329411X13178124951231 · doi:10.1179/174329411x13178124951231
  45. Sun, 2012, Green roof as a green material of building in mitigating heat island effect in Taipei city, Appl Mech Mater, 193–194, 368, 10.4028/www.scientific.net/AMM.193-194.368 · doi:10.4028/www.scientific.net/amm.193-194.368
  46. Sun, 2012, Vegetation as a material of roof and city to cool down the temperature, Adv Mater Res, 461, 552, 10.4028/www.scientific.net/AMR.461.552 · doi:10.4028/www.scientific.net/amr.461.552
  47. Ghiabaklou, 2003, Thermal comfort prediction for a new passive cooling system, Build Environ, 38, 883, 10.1016/S0360-1323(03)00028-3 · doi:10.1016/s0360-1323(03)00028-3
  48. Belarbi, 2006, Modeling of water spray evaporation: application to passive cooling of buildings, Sol Energy, 80, 1540, 10.1016/j.solener.2006.01.004 · doi:10.1016/j.solener.2006.01.004
  49. He, 2011, A design supporting simulation system for predicting and evaluating the cool microclimate creating effect of passive evaporative cooling walls, Build Environ, 46, 584, 10.1016/j.buildenv.2010.09.005 · doi:10.1016/j.buildenv.2010.09.005
  50. Melero S, Morgado I, Neila FJ, Acha C. Passive evaporative cooling by porous ceramic elements integrated in a trombe wall. PLEA 2011 - Architecture and sustainable development, conference proceedings of the 27th international conference on passive and low energy architecture. 2011. p. 267–72.
  51. Sabzevari A, Golneshan AA, Yaghoubi MA. Performance of wind towers for solar passive cooling in hot arid regions. ASME-JSES-JSME international solar energy conference. 1991. p. 97–101.
  52. Bahadori, 1994, Viability of wind towers in achieving summer comfort in the hot arid regions of the middle east, Renew Energy, 5, 879, 10.1016/0960-1481(94)90108-2 · doi:10.1016/0960-1481(94)90108-2
  53. Bouchahm Y, Bourbia F, Belhamri A. Improvement on wind towers to meet comfort conditions for hot dry climate (Ouargla, Algeria). 22nd International Conference, PLEA 2005: Passive and low energy architecture - environmental sustainability: the challenge of awareness in developing societies, proceedings, 1. 2005. p. 467–72.
  54. Kalantar, 2008, Numerical simulation of cooling performance of wind tower (Baud-Geer) in hot and arid region, Renew Energy, 34, 246, 10.1016/j.renene.2008.03.007 · doi:10.1016/j.renene.2008.03.007
  55. Bahadori, 2008, Experimental investigation of new designs of wind towers, Renew Energy, 33, 2273, 10.1016/j.renene.2007.12.018 · doi:10.1016/j.renene.2007.12.018
  56. Bansal, 1994, A study of solar chimney assisted wind tower system for natural ventilation in buildings, Build Environ, 29, 495, 10.1016/0360-1323(94)90008-6 · doi:10.1016/0360-1323(94)90008-6
  57. Li, 2012, Preliminary investigation of a novel solar and wind energy extraction system, Proc Inst Mech Eng A: J Power Energy, 226, 73, 10.1177/0957650911424364 · doi:10.1177/0957650911424364
  58. Lehmann, 2010, Eawag Forum Chriesbach - Simulation and measurement of energy performance and comfort in a sustainable office building, Energy Build, 42, 1958, 10.1016/j.enbuild.2010.06.002 · doi:10.1016/j.enbuild.2010.06.002
  59. Yun, 2010, Night-time naturally ventilated offices: statistical simulations of window-use patterns from field monitoring, Sol Energy, 84, 1216, 10.1016/j.solener.2010.03.029 · doi:10.1016/j.solener.2010.03.029
  60. Jenkins, 2009, The importance of office internal heat gains in reducing cooling loads in a changing climate, Int J Low-Carbon Technol, 4, 134, 10.1093/ijlct/ctp019 · doi:10.1093/ijlct/ctp019
  61. Ghadiri, 2011, The effect of tower height in square plan wind catcher on its thermal behavior, Aust J Basic Appl Sci, 5, 381
  62. Ogasawara, 1979, Effect of energy conservation by controlled ventilation: case study in a department store, Energy Build, 2, 3, 10.1016/0378-7788(79)90014-8 · doi:10.1016/0378-7788(79)90014-8
  63. Jackman PJ. Natural ventilation principles in design. CIBS Symposium "Natural ventilation by design. London. 2nd December 1980. p. 8-21.
  64. Vijayalaxmi, 2009, The thermal comfort of a naturally ventilated house resulting from the evaporative cooling of a ceiling fan in the hot-humid climate of Chennai, India, Int J Ventil, 8, 135, 10.1080/14733315.2006.11683839 · doi:10.1080/14733315.2006.11683839
  65. Silveira FM, Labaki LC. Use of natural ventilation in reducing building energy consumption in single-family housing in Brazil. 2012 International Conference on Renewable Energies for Developing Countries, REDEC 2012. 2012. · doi:10.1109/redec.2012.6416709
  66. Uno, 2012, Reduction of energy consumption by AC due to air tightness and ventilation strategy in residences in hot and humid climates, J Asian Archit Build Eng, 11, 407, 10.3130/jaabe.11.407 · doi:10.3130/jaabe.11.407
  67. Simonetti, 2008, Numerical and experimental study of an airing device for controlled natural ventilation of a building, Int J Vent, 7, 187, 10.1080/14733315.2008.11683811 · doi:10.1080/14733315.2008.11683811
  68. Liu X, Zhang L, Zhang Y, Meng Q. The study on optimization strategies of natural ventilation in an exhibition design. 2011 International Conference on Multimedia Technology, ICMT 2011. 2011. p. 4236–9.
  69. Khafaji OMA, Murta KH. Controlled ventilation as a cooling agent in school design for arid tropical areas. 1990. · doi:10.1007/978-94-017-0556-1_33
  70. Solaini, 1998, Simultaneous application of different natural cooling technologies to an experimental building, Renew Energy, 15, 277, 10.1016/S0960-1481(98)00173-6 · doi:10.1016/s0960-1481(98)00173-6
  71. Brandemuehl, 1999, Impact of demand-controlled and economizer ventilation strategies on energy use in buildings, ASHRAE Trans, 105
  72. Oropeza-Perez, 2014, Potential of natural ventilation in temperate countries - a case study of Denmark, Appl Energy, 114, 520, 10.1016/j.apenergy.2013.10.008 · doi:10.1016/j.apenergy.2013.10.008
  73. Mysen, 2003, Demand controlled ventilation for office cubicles - can it be profitable?, Energy Build, 35, 657, 10.1016/S0378-7788(02)00212-8 · doi:10.1016/s0378-7788(02)00212-8
  74. Bauman, 1991, Performance testing of a floor-based, occupant-controlled office ventilation system, ASHRAE Trans, pt 1, 553
  75. Cooper, 1997, Opportunities for demand controlled ventilation, J Therm Insul Build Envel, 20, 199, 10.1177/109719639702000303 · doi:10.1177/109719639702000303
  76. Atkinson, 1997, Demand-controlled ventilation of an entertainment club, ASHRAE Trans, 103, 375
  77. Hernandez P, Kenny P. Optimising life cycle energy performance of housing: the value of occupancy control. PLEA 2009 -Architecture energy and the occupant's perspective: proceedings of the 26th international conference on passive and low energy architecture. 2009.
  78. Baiyounes, 2013, Comparison study of solar cooling techniques for an institutional building in subtropical Queensland, Australia, Renew Sustain Energy Rev, 23, 421, 10.1016/j.rser.2013.02.044 · doi:10.1016/j.rser.2013.02.044
  79. Gebreslassie, 2012, Solar assisted solar cooling cycles for reduction of global warming: a multi-objective optimization approach, Sol Energy, 86, 2083, 10.1016/j.solener.2012.04.010 · doi:10.1016/j.solener.2012.04.010
  80. Albers, 2014, New absorption chiller and control strategy for the solar assisted cooling system at the German environment agency, Int J Refrig, 39, 48, 10.1016/j.ijrefrig.2013.08.015 · doi:10.1016/j.ijrefrig.2013.08.015
  81. Ochoa CE, Capeluto IG. Intelligent facades in hot climates: energy and comfort strategies for successful application. PLEA 2008 - Towards zero energy building: 25th PLEA international conference on passive and low energy architecture, Conference Proceedings. 2008.
  82. O'Hegarty, 2016, Review and analysis of solar thermal facades, Sol Energy, 135, 408, 10.1016/j.solener.2016.06.006 · doi:10.1016/j.solener.2016.06.006
  83. Danks, 2016, Assessing reflected sunlight from building facades: a literature review and proposed criteria, Renew Sustain Energy Rev, 103, 193
  84. Agathokleous, 2016, Double skin facades (DSF) and building integrated photovoltaics (BIPV): a review of configurations and heat transfer characteristics, Renew Energy, 89, 743, 10.1016/j.renene.2015.12.043 · doi:10.1016/j.renene.2015.12.043
  85. Kensek, 2011, Environment control systems for sustainable desgin: a methodology for testing, simulating and comparing kinetic facade systems, J Creative Sustain Archit Built Environ, 1, 27
  86. Suralkar, 2011, Solar responsive kinetic facade shading system inpired by plant movements in nature, People Build, 23
  87. Li, 2008, An analysis of building energy performances and benefits using solar façades, Proc Inst Mech Eng A: J Power Energy, 222, 299, 10.1243/09576509JPE404 · doi:10.1243/09576509jpe404
  88. Oropeza-Perez, 2012, Model of natural ventilation by using a coupled thermal-airflow simulation program, Energy Build, 49, 388, 10.1016/j.enbuild.2012.02.039 · doi:10.1016/j.enbuild.2012.02.039

Cited by

See all 184

Metadata

Authors
Oropeza-Perez, I., & Østergaard, P. A.
Venue
Renewable and Sustainable Energy Reviews
Publisher
Elsevier BV
Published
2018-02
Volume
82
Pages
531-544
ISSN
1364-0321 (ISSN-L)
OpenAlex
W2761935159
Cited by
184
References
117
FWCI
9.29
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Active and passive cooling methods for dwellings: A review. https://app.cochat.ai/papers/10.1016/j.rser.2017.09.059
The paper
Oropeza-Perez, I., & Østergaard, P. A. (2018). Active and passive cooling methods for dwellings: A review. Renewable and Sustainable Energy Reviews. https://doi.org/10.1016/j.rser.2017.09.059

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.