The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
On the understanding of the mean radiant temperature within both the indoor and outdoor environment, a critical review
Open accessAbstract
Abstract Mean radiant temperature is central to our understanding of the radiant heat exchange between the human body and surrounding environment. This paper will present a review of the concept's evolution including its qualitative definition, methods of quantitative evaluation and corresponding challenges. In the process, this review suggests that more effort needs to be invested in addressing the geometric complexities of radiant heat transfer in research into MRT; the ASHRAE definition is broad and is liable to simplification, and research which uses the definition relies on a variety of simplifications, often without acknowledging the degree of geometric complexity which exists in reality. Existing means of obtaining an estimate of mean radiant temperature range from direct measurements using globe thermometers or net radiometers, to computational simulations, and are widely used for studies within indoor and outdoor environments. Previous literature studying the correlation between air temperature and MRT has found equivalence ratios, the relative importance of convection to radiation, ranging from 0.71 to 1.4, however, it is often assumed to be 1.0 in current research practices. We also identified a rapid increase in the usage of MRT in biometeorological studies during the last ten years on top of the increased usage in indoor environment sensing and modeling in light of recent developments in heating and cooling systems. Recent efforts to include the short-wave component in indoor MRT characterization have shown an increase in cooling capacity of radiant floors from 32 to 110 W/m2; significantly decreasing peak energy demand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hoyt, T., Arens, E., & Zhang, H. (2015) · Building and Environment · doi:10.1016/j.buildenv.2014.09.010 · Cited by 607
Lindberg, F., Holmer, B., & Thorsson, S. (2008) · International Journal of Biometeorology · doi:10.1007/s00484-008-0162-7 · Cited by 574
Perinasal Imaging of Physiological Stress and Its Affective Potential
Shastri, D., Papadakis, M., Tsiamyrtzis, P., Bass, B., & Pavlidis, I. (2012) · IEEE Transactions on Affective Computing · doi:10.1109/t-affc.2012.13 · Cited by 89
Cited by
Di Napoli, C., Barnard, C., Prudhomme, C., Cloke, H. L., & Pappenberger, F. (2021) · Geoscience Data Journal · doi:10.1002/gdj3.102 · Cited by 295
Metadata
- Authors
- Guo, H., Aviv, D., Loyola, M., Teitelbaum, E., Houchois, N., & Meggers, F.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 117
- Pages
- 109207
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2981888979
- Cited by
- 200
- References
- 3
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the understanding of the mean radiant temperature within both the indoor and outdoor environment, a critical review. https://app.cochat.ai/papers/10.1016/j.rser.2019.06.014
- The paper
- Guo, H., Aviv, D., Loyola, M., Teitelbaum, E., Houchois, N., & Meggers, F. (2020). On the understanding of the mean radiant temperature within both the indoor and outdoor environment, a critical review. Renewable and Sustainable Energy Reviews. https://doi.org/10.1016/j.rser.2019.06.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.