Cited by 232Electrochemical sensors and biosensorsBiosensors and Analytical DetectionDiabetes Management and Research

Noninvasive glucose monitoring using saliva nano-biosensor

Open access
Zhang, Wenjun, Du, Yunqing, Wang, Ming L.·2015·Sensing and Bio-Sensing Research

Abstract

Millions of people worldwide live with diabetes and several millions die from it each year. A noninvasive, painless method of glucose testing would highly improve compliance and glucose control while reducing complications and overall disease management costs. To provide accurate, low cost, and continuous glucose monitoring, we have developed a unique, disposable saliva nano-biosensor. More than eight clinical trials on real-time noninvasive salivary glucose monitoring were carried out on two healthy individuals (a 2–3 h-period for each trial, including both regular food and standard glucose beverage intake with more than 35 saliva samples obtained). Excellent clinical accuracy was revealed as compared to the UV Spectrophotometer. By measuring subjects’ salivary glucose and blood glucose in parallel, we found the two generated profiles share the same fluctuation trend but the correlation between them is individual dependent. There is a time lag between the peak glucose values from blood and from saliva. However, the correlation between the two glucose values at fasting is constant for each person enabling noninvasive diagnosis of diabetes through saliva instead of blood. Furthermore, a good correlation of glucose levels in saliva and in blood before and 2 h after glucose intake was observed. Glucose monitoring before and 2 h after meals is usually prescribed by doctors for diabetic patients. Thus, this disposable biosensor will be an alternative for real-time salivary glucose tracking at any time.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.sbsr.2015.02.002

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Salivary glucose can offer an alternative painless screening route for diabetic patients.

    “Salivary glucose can thus offer an alternative painless screening route for diabetic patients149-154.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [151]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 44 · Cited by 232

Research works printed but not linked: 1

  1. W. Zhang, Y. Du, M. Wang, On-chip ultra-sensitive glucose sensing using multilayer films composed of single-walled carbon nanotubes-gold nanoparticles-and glucose oxidase, Sens. Actuators B (2015) (under review).

Authors
Zhang, W., Du, Y., & Wang, M. L.
Affiliations
Northeastern University (US)
Corresponding author
Zhang, Wenjun
Venue
Sensing and Bio-Sensing Research
Publisher
Elsevier BV
Published
2015-06
Volume
4
Pages
23-29
ISSN
2214-1804 (ISSN-L)
OpenAlex
W2085868139
Cited by
232
References
44
Citations by year
2026: 10 · 2025: 15 · 2024: 26 · 2023: 33 · 2022: 26 · 2021: 28 · 2020: 20 · 2019: 21 · 2018: 23 · 2017: 13 · 2016: 15 · 2015: 2
FWCI
8.52
Type
journal article
Language
en
Open access
Locations
  • Sensing and Bio-Sensing Research (publishedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
NBS (0731102)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
Keywords
non-invasive glucose monitoring, salivary glucose, nanobiosensors, disposable biosensor, diabetes diagnosis, glucose ingestion, continuous glucose monitoring, saliva

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review