Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The next generation of devices for personal healthcare monitoring will comprise molecular sensors to monitor analytes of interest in the skin compartment. Transdermal devices based on microneedles offer an excellent opportunity to explore the dynamics of molecular markers in the interstitial fluid, however good acceptability of these next generation devices will require several technical problems associated with current commercially available wearable sensors to be overcome. These particularly include reliability, comfort and cost. An essential pre-requisite for transdermal molecular sensing devices is that they can be fabricated using scalable technologies which are cost effective. We present here a minimally invasive microneedle array as a continuous monitoring platform technology. Method for scalable fabrication of these structures is presented. The microneedle arrays were characterised mechanically and were shown to penetrate human skin under moderate thumb pressure. They were then functionalised and evaluated as glucose, lactate and theophylline biosensors. The results suggest that this technology can be employed in the measurement of metabolites, therapeutic drugs and biomarkers and could have an important role to play in the management of chronic diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Fabrication Methods for Microfluidic Devices: An Overview
Scott, S., & Ali, Z. (2021) · Micromachines · doi:10.3390/mi12030319 · Cited by 479
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Advances in Antimicrobial Microneedle Patches for Combating Infections
Jamaledin, R., Yiu, C. K. Y., Zare, E. N., Niu, L., Vecchione, R., Chen, G., Gu, Z., Tay, F. R., & Makvandi, P. (2020) · Advanced Materials · doi:10.1002/adma.202002129 · Cited by 461
Metadata
- Authors
- Sharma, S., Saeed, A., Johnson, C., Gadegaard, N., & Cass, A. E.
- Venue
- Sensing and Bio-Sensing Research
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 13
- Pages
- 104-108
- ISSN
- 2214-1804 (ISSN-L)
- OpenAlex
- W2529894336
- Cited by
- 99
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring. https://app.cochat.ai/papers/10.1016/j.sbsr.2016.10.004
- The paper
- Sharma, S., Saeed, A., Johnson, C., Gadegaard, N., & Cass, A. E. (2017). Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring. Sensing and Bio-Sensing Research. https://doi.org/10.1016/j.sbsr.2016.10.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.