Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data

Open access
Pickup, J. C., Freeman, S. C., Sutton, A. J.·2011·BMJ

Abstract

OBJECTIVE: To determine the clinical effectiveness of real time continuous glucose monitoring compared with self monitoring of blood glucose in type 1 diabetes. DESIGN: Meta-analysis of randomised controlled trials. DATA SOURCES: Cochrane database for randomised controlled trials, Ovid Medline, Embase, Google Scholar, lists of papers supplied by manufacturers of continuous glucose monitors, and cited literature in retrieved articles. Studies reviewed Randomised controlled trials of two or more months' duration in men and non-pregnant women with type 1 diabetes that compared real time continuous glucose monitoring with self monitoring of blood glucose and where insulin delivery was the same in both arms. Analysis Two step meta-analysis of individual patient data with the primary outcome of final glycated haemoglobin (HbA(1c)) percentage and area under the curve of hypoglycaemia (glucose concentration <3.9 mmol/L) during either treatment, followed by one step metaregression exploring patient level determinants of HbA(1c) and hypoglycaemia. RESULTS: Six trials were identified, consisting of 449 patients randomised to continuous glucose monitoring and 443 to self monitoring of blood glucose. The overall mean difference in HbA(1c) for continuous glucose monitoring versus self monitoring of blood glucose was -0.30% (95% confidence interval -0.43% to -0.17%) (-3.0, -4.3 to -1.7 mmol/mol). A best fit regression model of determinants of final HbA(1c) showed that for every one day increase of sensor usage per week the effect of continuous glucose monitoring versus self monitoring of blood glucose increased by 0.150% (95% credibility interval -0.194% to -0.106%) (1.5, -1.9 to -1.1 mmol/mol) and every 1% (10 mmol/mol) increase in baseline HbA(1c) increased the effect by 0.126% (-0.257% to 0.0007%) (1.3, -2.6 to 0.0 mmol/mol). The model estimates that, for example, a patient using the sensor continuously would experience a reduction in HbA(1c) of about 0.9% (9 mmol/mol) when the baseline HbA(1c) is 10% (86 mmol/mol). The overall reduction in area under the curve of hypoglycaemia was -0.28 (-0.46 to -0.09), corresponding to a reduction in median exposure to hypoglycaemia of 23% for continuous glucose monitoring compared with self monitoring of blood glucose. In a best fit regression model, baseline area under the curve of hypoglycaemia was only weakly related to the effect of continuous glucose monitoring compared with self monitoring of blood glucose on hypoglycaemia outcome, and sensor usage was unrelated to hypoglycaemia at outcome. CONCLUSIONS: Continuous glucose monitoring was associated with a significant reduction in HbA(1c) percentage, which was greatest in those with the highest HbA(1c) at baseline and who most frequently used the sensors. Exposure to hypoglycaemia was also reduced during continuous glucose monitoring. The most cost effective or appropriate use of continuous glucose monitoring is likely to be when targeted at people with type 1 diabetes who have continued poor control during intensified insulin therapy and who frequently use continuous glucose monitoring.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.d3805

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Whether CSII is better, overall, than multiple daily injection for management of type 1 diabetes is debated, since outcomes reported in studies have varied substantially.

    “However, whether CSII is better, overall, than multiple daily injection for management of type 1 diabetes is debated, since outcomes reported in studies have varied substantially.90”

    From Type 1 diabetes (2014) · cites this paper as [90]

    The Methods (page unavailable) say the analysis compared continuous glucose monitoring with self-monitoring and excluded trials in which insulin treatment differed between arms. The Results’ Study characteristics (page unavailable) list CSII and multiple daily injections as delivery methods, but do not assess whether CSII is better or report variability in outcomes from that comparison. I searched for a discussion of conflicting CSII-versus-injection results and found none in our copy. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 16

  1. [1]Mastrototaro JJ. The MiniMed continuous glucose monitoring system. Diabetes Technol Therapeut 2000; 2: 13-8. 11469627
  2. [2]Klonoff DC. Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005; 28: 1231-9. 15855600
  3. [3]Deiss D, Bollinder J, Riveline JP, Battelino T, Bosi E, Tubiana-Rufi N, et al. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 2006; 29: 2730-2. 17130215
  4. [4]Hirsch IB, Abelseth J, Bode BW, Fischer JS, Kaufman FR, Mastrototaro J, et al. Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Therapeut 2008; 10: 377-83. 18715214
  5. [7]O’Connell MA, Donath S, O’Neal DN, Colman PG, Ambler GR, Jones TW, et al. Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trials. Diabetologia 2009; 52: 1250-70. 19396424
  6. [8]Raccah D, Sulmont V, Reznik Y, Guerci B, Renard E, Hamaire H, et al. Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes. Diabetes Care 2009; 32: 2245-50. 19767384 PMC2782985
  7. [9]Juvenile Diabetes Foundation Continuous Glucose Monitoring Study Group. Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes. Diabetes Care 2009; 32: 1947-53. 19675206 PMC2768196
  8. [10]Lambert PC, Sutton AJ, Abrams KR, Jones DR. A comparison of summary patient level covariates in meta-regression with individual patient data meta-analyses. J Clin Epidemiol 2002; 55: 86-94. 11781126
  9. [12]Hermanides J, Nøgaard K, Brutomesso D, Mathieu C, Frid A, Dyan CM, et al. Sensor augmented pump therapy substantially lowers HbA1c: a randomized controlled trial. Diabetologia 2009; 52: S43 (Abstract).
  10. [15]American Diabetes Association Working Group on Hypoglycemia. Defining and reporting hypoglycemia in diabetes. Diabetes Care 2005; 28: 1245-9. 15855602
  11. [16]Spiegelhalter DJ, Best NG, Carline BP, Van der Linde A. Bayesian measures of model complexity and fit. J Roy Stat Soc Series B 2002; 64: 583-640.
  12. [17]Riley RD, Steyerberg EW. Meta-analysis of a binary outcome using individual participant data and aggregate data. Res Synth Meth 2010; 1: 2-19. 26056090
  13. [18]Bagos PG, Nikolopoulos GK. Mixed-effects Poisson regression models for meta-analysis of follow up studies with constant or varying durations. Int J Biostat 2009; 5: 21:article 21.
  14. [21]Diabetes Control and Complications Trial Research Group. The absence of a glycemic threshold for the development of long-term complications: the perspective of the Diabetes Control and Complications Trial. Diabetes 1996; 45: 1289-98. 8826962
  15. [22]Moher D, Jadad AR, Tugwell P. Assessing the quality of randomised controlled trials: current issues and future directions. Int J Technol Assess Healthcare 1996; 12: 195-208. 8707495
  16. [24]Hammond PJ, Amiel SA, Dayan CM, Kerr D, Pickup JC, Shaw JAM, et al. ABCD position statement on continuous glucose monitoring: use of glucose sensing in outpatient clinical diabetes care. Pract Diab Int 2010; 27: 1-3.

Cited by

Sorted by citations

Authors
Pickup, J. C., Freeman, S. C., & Sutton, A. J.
Affiliations
  • Guy's Hospital (GB)
  • University of Leicester (GB)
Corresponding author
Pickup, J. C.
Venue
BMJ
Publisher
BMJ
Published
2011-07-07
Volume
343
Issue
jul07 1
Pages
d3805-d3805
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W1995972413
Cited by
541
References
6
Citations by year
2026: 13 · 2025: 13 · 2024: 18 · 2023: 16 · 2022: 30 · 2021: 38 · 2020: 51 · 2019: 51 · 2018: 45 · 2017: 48 · 2016: 41 · 2015: 42 · 2014: 41 · 2013: 43 · 2012: 40
FWCI
6.03
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • BMJ (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Figshare (submittedVersion, cc-by)
  • Research Portal (King's College London) (submittedVersion)
  • Leicester Research Archive (University of Leicester) (submittedVersion)
  • Leicester Research Archive (University of Leicester) (submittedVersion, other-oa)
Funders
Engineering and Physical Sciences Research Council
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, continuous glucose monitoring, self-monitoring of blood glucose, HbA1c, hypoglycemia, glycemic control, meta-regression, insulin delivery, diabetes technology, cost-effectiveness
MeSH terms
Adult, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Male, Blood Glucose Self-Monitoring, Randomized Controlled Trials as Topic, Treatment Outcome, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review