Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data
Open accessAbstract
OBJECTIVE: To determine the clinical effectiveness of real time continuous glucose monitoring compared with self monitoring of blood glucose in type 1 diabetes. DESIGN: Meta-analysis of randomised controlled trials. DATA SOURCES: Cochrane database for randomised controlled trials, Ovid Medline, Embase, Google Scholar, lists of papers supplied by manufacturers of continuous glucose monitors, and cited literature in retrieved articles. Studies reviewed Randomised controlled trials of two or more months' duration in men and non-pregnant women with type 1 diabetes that compared real time continuous glucose monitoring with self monitoring of blood glucose and where insulin delivery was the same in both arms. Analysis Two step meta-analysis of individual patient data with the primary outcome of final glycated haemoglobin (HbA(1c)) percentage and area under the curve of hypoglycaemia (glucose concentration <3.9 mmol/L) during either treatment, followed by one step metaregression exploring patient level determinants of HbA(1c) and hypoglycaemia. RESULTS: Six trials were identified, consisting of 449 patients randomised to continuous glucose monitoring and 443 to self monitoring of blood glucose. The overall mean difference in HbA(1c) for continuous glucose monitoring versus self monitoring of blood glucose was -0.30% (95% confidence interval -0.43% to -0.17%) (-3.0, -4.3 to -1.7 mmol/mol). A best fit regression model of determinants of final HbA(1c) showed that for every one day increase of sensor usage per week the effect of continuous glucose monitoring versus self monitoring of blood glucose increased by 0.150% (95% credibility interval -0.194% to -0.106%) (1.5, -1.9 to -1.1 mmol/mol) and every 1% (10 mmol/mol) increase in baseline HbA(1c) increased the effect by 0.126% (-0.257% to 0.0007%) (1.3, -2.6 to 0.0 mmol/mol). The model estimates that, for example, a patient using the sensor continuously would experience a reduction in HbA(1c) of about 0.9% (9 mmol/mol) when the baseline HbA(1c) is 10% (86 mmol/mol). The overall reduction in area under the curve of hypoglycaemia was -0.28 (-0.46 to -0.09), corresponding to a reduction in median exposure to hypoglycaemia of 23% for continuous glucose monitoring compared with self monitoring of blood glucose. In a best fit regression model, baseline area under the curve of hypoglycaemia was only weakly related to the effect of continuous glucose monitoring compared with self monitoring of blood glucose on hypoglycaemia outcome, and sensor usage was unrelated to hypoglycaemia at outcome. CONCLUSIONS: Continuous glucose monitoring was associated with a significant reduction in HbA(1c) percentage, which was greatest in those with the highest HbA(1c) at baseline and who most frequently used the sensors. Exposure to hypoglycaemia was also reduced during continuous glucose monitoring. The most cost effective or appropriate use of continuous glucose monitoring is likely to be when targeted at people with type 1 diabetes who have continued poor control during intensified insulin therapy and who frequently use continuous glucose monitoring.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Whether CSII is better, overall, than multiple daily injection for management of type 1 diabetes is debated, since outcomes reported in studies have varied substantially.
“However, whether CSII is better, overall, than multiple daily injection for management of type 1 diabetes is debated, since outcomes reported in studies have varied substantially.90”
From Type 1 diabetes (2014) · cites this paper as [90]
The Methods (page unavailable) say the analysis compared continuous glucose monitoring with self-monitoring and excluded trials in which insulin treatment differed between arms. The Results’ Study characteristics (page unavailable) list CSII and multiple daily injections as delivery methods, but do not assess whether CSII is better or report variability in outcomes from that comparison. I searched for a discussion of conflicting CSII-versus-injection results and found none in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · see citing works
Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
Jadad, A. R., Moore, R. A., Carroll, D., Jenkinson, C., Reynolds, D. J. M., Gavaghan, D. J., & McQuay, H. J. (1996) · Controlled Clinical Trials · doi:10.1016/0197-2456(95)00134-4 · Cited by 17,582 · see citing works
Meta-analysis of individual participant data: rationale, conduct, and reporting
Riley, R. D., Lambert, P. C., & Abo-Zaid, G. (2010) · BMJ · doi:10.1136/bmj.c221 · Cited by 1,701 · see citing works
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894 · see citing works
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399 · see citing works
Flagged first, then by citations
Research works printed but not linked: 16
- [1]Mastrototaro JJ. The MiniMed continuous glucose monitoring system. Diabetes Technol Therapeut 2000; 2: 13-8. 11469627
- [2]Klonoff DC. Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005; 28: 1231-9. 15855600
- [3]Deiss D, Bollinder J, Riveline JP, Battelino T, Bosi E, Tubiana-Rufi N, et al. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 2006; 29: 2730-2. 17130215
- [4]Hirsch IB, Abelseth J, Bode BW, Fischer JS, Kaufman FR, Mastrototaro J, et al. Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Therapeut 2008; 10: 377-83. 18715214
- [7]O’Connell MA, Donath S, O’Neal DN, Colman PG, Ambler GR, Jones TW, et al. Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trials. Diabetologia 2009; 52: 1250-70. 19396424
- [8]Raccah D, Sulmont V, Reznik Y, Guerci B, Renard E, Hamaire H, et al. Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes. Diabetes Care 2009; 32: 2245-50. 19767384 PMC2782985
- [9]Juvenile Diabetes Foundation Continuous Glucose Monitoring Study Group. Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes. Diabetes Care 2009; 32: 1947-53. 19675206 PMC2768196
- [10]Lambert PC, Sutton AJ, Abrams KR, Jones DR. A comparison of summary patient level covariates in meta-regression with individual patient data meta-analyses. J Clin Epidemiol 2002; 55: 86-94. 11781126
- [12]Hermanides J, Nøgaard K, Brutomesso D, Mathieu C, Frid A, Dyan CM, et al. Sensor augmented pump therapy substantially lowers HbA1c: a randomized controlled trial. Diabetologia 2009; 52: S43 (Abstract).
- [15]American Diabetes Association Working Group on Hypoglycemia. Defining and reporting hypoglycemia in diabetes. Diabetes Care 2005; 28: 1245-9. 15855602
- [16]Spiegelhalter DJ, Best NG, Carline BP, Van der Linde A. Bayesian measures of model complexity and fit. J Roy Stat Soc Series B 2002; 64: 583-640.
- [17]Riley RD, Steyerberg EW. Meta-analysis of a binary outcome using individual participant data and aggregate data. Res Synth Meth 2010; 1: 2-19. 26056090
- [18]Bagos PG, Nikolopoulos GK. Mixed-effects Poisson regression models for meta-analysis of follow up studies with constant or varying durations. Int J Biostat 2009; 5: 21:article 21.
- [21]Diabetes Control and Complications Trial Research Group. The absence of a glycemic threshold for the development of long-term complications: the perspective of the Diabetes Control and Complications Trial. Diabetes 1996; 45: 1289-98. 8826962
- [22]Moher D, Jadad AR, Tugwell P. Assessing the quality of randomised controlled trials: current issues and future directions. Int J Technol Assess Healthcare 1996; 12: 195-208. 8707495
- [24]Hammond PJ, Amiel SA, Dayan CM, Kerr D, Pickup JC, Shaw JAM, et al. ABCD position statement on continuous glucose monitoring: use of glucose sensing in outpatient clinical diabetes care. Pract Diab Int 2010; 27: 1-3.
Cited by
Sorted by citations
Atkinson, M. A., Eisenbarth, G. S., & Michels, A. W. (2014) · The Lancet · doi:10.1016/s0140-6736(13)60591-7 · Cited by 2,713 · see citing works
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · see citing works
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893 · see citing works
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803 · see citing works
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705 · see citing works
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635 · see citing works
Handelsman, Y., Bloomgarden, Z. T., Grunberger, G., Umpierrez, G., Zimmerman, R. S., Bailey, T. S., Blonde, L., Bray, G. A., Cohen, A. J., Dagogo-Jack, S., et al. (2015) · Endocrine Practice · doi:10.4158/ep15672.glsuppl · Cited by 559 · see citing works
Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522 · see citing works
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493 · see citing works
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494 · see citing works
Home Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450 · see citing works
van Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H. (2016) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30193-0 · Cited by 386 · see citing works
Maiorino, M. I., Signoriello, S., Maio, A., Chiodini, P., Bellastella, G., Scappaticcio, L., Longo, M., Giugliano, D., & Esposito, K. (2020) · Diabetes Care · doi:10.2337/dc19-1459 · Cited by 364 · see citing works
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329 · see citing works
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318 · see citing works
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307 · see citing works
Ryan, R. E., Santesso, N., Lowe, D., Hill, S., Grimshaw, J. M., Prictor, M., Kaufman, C., Cowie, G., & Taylor, M. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007768.pub3 · Cited by 273 · see citing works
Insulin-pump therapy for type 1 diabetes mellitus
Pickup, J. C. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1113948 · Cited by 270 · see citing works
Self-citationReddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245 · see citing works
Šoupal, J., Petruželková, L., Grunberger, G., Hásková, A., Flekač, M., Matoulek, M., Mikeš, O., Pelcl, T., Škrha, J., Horová, E., et al. (2020) · Diabetes Care · doi:10.2337/dc19-0888 · Cited by 242 · see citing works
The Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes
Secher, A. L., Ringholm, L., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2013) · Diabetes Care · doi:10.2337/dc12-2360 · Cited by 214 · see citing works
Mauras, N., Beck, R., Xing, D., Ruedy, K., Buckingham, B., Tansey, M., White, N. H., Weinzimer, S. A., Tamborlane, W., Kollman, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1746 · Cited by 204 · see citing works
7. Diabetes Technology: <i>Standards of Medical Care in Diabetes—2021</i>
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202 · see citing works
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197 · see citing works
Teo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186 · see citing works
Lawton, J., Blackburn, M., Allen, J., Campbell, F., Elleri, D., Leelarathna, L., Rankin, D., Tauschmann, M., Thabit, H., & Hovorka, R. (2018) · BMC Endocrine Disorders · doi:10.1186/s12902-018-0239-1 · Cited by 174 · see citing works
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170 · see citing works
7. Diabetes Technology: <i>Standards of Medical Care in Diabetes—2019</i>
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179 · see citing works
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135 · see citing works
Cardona-Hernandez, R., Schwandt, A., Alkandari, H., Bratke, H., Chobot, A., Coles, N., Corathers, S., Goksen, D., Goss, P., Imane, Z., et al. (2021) · Diabetes Care · doi:10.2337/dc20-1674 · Cited by 129 · see citing works
Seidu, S., Kunutsor, S. K., Ajjan, R. A., & Choudhary, P. (2024) · Diabetes Care · doi:10.2337/dc23-1520 · Cited by 124 · see citing works
Beck, R. W., Riddlesworth, T. D., Ruedy, K. J., Kollman, C., Ahmann, A. J., Bergenstal, R. M., Bhargava, A., Bode, B. W., Haller, S., Kruger, D. F., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30217-6 · Cited by 119 · see citing works
Hypoglycaemia during pregnancy in women with Type 1 diabetes
Ringholm, L., Pedersen‐Bjergaard, U., Thorsteinsson, B., Damm, P., & Mathiesen, E. R. (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2012.03604.x · Cited by 101 · see citing works
Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes
Slattery, D., & Choudhary, P. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0051 · Cited by 87 · see citing works
Castellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., Cignarelli, A., Laviola, L., & Giorgino, F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001092 · Cited by 84 · see citing works
Lorenz, C., Sandoval, W., & Mortellaro, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0028 · Cited by 80 · see citing works
Joubert, M., & Reznik, Y. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.12.010 · Cited by 70 · see citing works
Beato-Víbora, P. I., Quirós-López, C., Lázaro-Martín, L., Martín-Frías, M., Barrio-Castellanos, R., Gil-Poch, E., Arroyo-Díez, F. J., & Giménez-Álvarez, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0199 · Cited by 60 · see citing works
Choudhary, P., & Amiel, S. A. (2018) · Diabetologia · doi:10.1007/s00125-018-4566-6 · Cited by 52 · see citing works
Pleus, S., Ulbrich, S., Zschornack, E., Kamann, S., Haug, C., & Freckmann, G. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0171 · Cited by 47 · see citing works
Tanenbaum, M. L., Zaharieva, D. P., Addala, A., Ngo, J., Prahalad, P., Leverenz, B., New, C., Maahs, D. M., & Hood, K. K. (2021) · Diabetic Medicine · doi:10.1111/dme.14567 · Cited by 42 · see citing works
Chesser, H., Srinivasan, S., Puckett, C., Gitelman, S. E., & Wong, J. C. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221139873 · Cited by 40 · see citing works
Kropff, J., DeJong, J., del Favero, S., Place, J., Messori, M., Coestier, B., Farret, A., Boscari, F., Galasso, S., Avogaro, A., et al. (2017) · Diabetic Medicine · doi:10.1111/dme.13268 · Cited by 40 · see citing works
Real-World Data from the First U.S. Commercial Users of an Implantable Continuous Glucose Sensor
Sanchez, P., Ghosh-Dastidar, S., Tweden, K. S., & Kaufman, F. R. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0234 · Cited by 40 · see citing works
Hermanns, N., Schumann, B., Kulzer, B., & Haak, T. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524105 · Cited by 39 · see citing works
Cantú-Rodríguez, O. G., Lavalle-González, F., Herrera-Rojas, M. Á., Jaime-Pérez, J. C., Hawing-Zárate, J. Á., Gutiérrez-Aguirre, C. H., Mancias-Guerra, C., González-Llano, O., Zapata-Garrido, A., Villarreal-Pérez, J. Z., et al. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-2776 · Cited by 39 · see citing works
Billings, L. K., Parkin, C. G., & Price, D. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0163 · Cited by 39 · see citing works
Lucidi, P., Porcellati, F., Bolli, G. B., & Fanelli, C. G. (2018) · Current Diabetes Reports · doi:10.1007/s11892-018-1065-6 · Cited by 38 · see citing works
Clinical approaches to treat impaired awareness of hypoglycaemia
Farrell, C. M., & McCrimmon, R. J. (2021) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188211000248 · Cited by 31 · see citing works
Grunberger, G., Sze, D., Ermakova, A., Sieradzan, R., Oliveria, T., & Miller, E. M. (2020) · Clinical Diabetes · doi:10.2337/cd19-0008 · Cited by 28 · see citing works
Tumminia, A., Sciacca, L., Frittitta, L., Squatrito, S., Vigneri, R., Le Moli, R., & Tomaselli, L. (2015) · Patient Preference and Adherence · doi:10.2147/ppa.s69482 · Cited by 20 · see citing works
“Previous studies, reporting that RT-CGM systems improve clinical outcomes only when they are used consistently, 2,7,9 confirm the critical role of patient acceptance for optimizing the benefits of all new treatments or technologies.”
Turk, N., Ramanujan, S., Shamloo, T., Craig, C., & McLaughlin, T. (2025) · Journal of the Endocrine Society · doi:10.1210/jendso/bvaf106 · Cited by 7 · see citing works
Talaiti, M., Liao, X., Abulimiti, N., Zeng, M., & Wang, Y. (2026) · Journal of Diabetes Research · doi:10.1155/jdr/1464982
- Authors
- Pickup, J. C., Freeman, S. C., & Sutton, A. J.
- Affiliations
- Guy's Hospital (GB)
- University of Leicester (GB)
- Corresponding author
- Pickup, J. C.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2011-07-07
- Volume
- 343
- Issue
- jul07 1
- Pages
- d3805-d3805
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- PMC
- PMC3131116
- OpenAlex
- W1995972413
- Cited by
- 541
- References
- 6
- Citations by year
- 2026: 13 · 2025: 13 · 2024: 18 · 2023: 16 · 2022: 30 · 2021: 38 · 2020: 51 · 2019: 51 · 2018: 45 · 2017: 48 · 2016: 41 · 2015: 42 · 2014: 41 · 2013: 43 · 2012: 40
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- BMJ (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Figshare (submittedVersion, cc-by)
- Research Portal (King's College London) (submittedVersion)
- Leicester Research Archive (University of Leicester) (submittedVersion)
- Leicester Research Archive (University of Leicester) (submittedVersion, other-oa)
- Funders
- Engineering and Physical Sciences Research Council
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, continuous glucose monitoring, self-monitoring of blood glucose, HbA1c, hypoglycemia, glycemic control, meta-regression, insulin delivery, diabetes technology, cost-effectiveness
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Male, Blood Glucose Self-Monitoring, Randomized Controlled Trials as Topic, Treatment Outcome, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review