The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Refractive index sensor based on all-dielectric gradient metasurface
Open accessAbstract
A new type of a refractive index sensor based on all-dielectric gradient metasurface was proposed and analyzed with making use of the finite element method (FEM). A new method of optical data processing which is based on intensity distribution over several diffraction orders was suggested. The intensity sensitivity of 4450%/RIU and the phase sensitivity of 1200 ° /RIU were demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novotny, L., & Hecht, B. (2025) · Cambridge University Press eBooks · doi:10.1017/9781108781503 · Cited by 6,220
Flat optics with designer metasurfaces
Yu, N., & Capasso, F. (2014) · Nature Materials · doi:10.1038/nmat3839 · Cited by 5,984
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Jahani, S., & Jacob, Z. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.304 · Cited by 1,965
Plasmonic nanorod metamaterials for biosensing
Kabashin, A. V., Evans, P., Pastkovsky, S., Hendren, W., Wurtz, G. A., Atkinson, R., Pollard, R., Podolskiy, V. A., & Zayats, A. V. (2009) · Nature Materials · doi:10.1038/nmat2546 · Cited by 1,744
Biosensors and their applications – A review
Mehrotra, P. (2016) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2015.12.002 · Cited by 1,526
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
High‐Efficiency Dielectric Huygens’ Surfaces
Decker, M., Staude, I., Falkner, M., Dominguez, J., Neshev, D. N., Brener, I., Pertsch, T., & Kivshar, Y. S. (2015) · Advanced Optical Materials · doi:10.1002/adom.201400584 · Cited by 1,334
Imaging-based molecular barcoding with pixelated dielectric metasurfaces
Tittl, A., Leitis, A., Liu, M., Yesilkoy, F., Choi, D.-Y., Neshev, D. N., Kivshar, Y. S., & Altug, H. (2018) · Science · doi:10.1126/science.aas9768 · Cited by 1,329
Damborský, P., Švitel, J., & Katrlík, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150010 · Cited by 907
Extreme sensitivity biosensing platform based on hyperbolic metamaterials
Sreekanth, K. V., Alapan, Y., ElKabbash, M., Ilker, E., Hinczewski, M., Gurkan, U. A., De Luca, A., & Strangi, G. (2016) · Nature Materials · doi:10.1038/nmat4609 · Cited by 777
Das Neves Gomes, C., Jacquet, O., Villiers, C., Thuéry, P., Ephritikhine, M., & Cantat, T. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201106864 · Cited by 695
High-Efficiency All-Dielectric Metasurfaces for Ultracompact Beam Manipulation in Transmission Mode
Shalaev, M. I., Sun, J., Tsukernik, A., Pandey, A., Nikolskiy, K., & Litchinitser, N. M. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b02926 · Cited by 626
Metasurface eyepiece for augmented reality
Lee, G.-Y., Hong, J.-Y., Hwang, S., Moon, S., Kang, H., Jeon, S., Kim, H., Jeong, J.-H., & Lee, B. (2018) · Nature Communications · doi:10.1038/s41467-018-07011-5 · Cited by 521
Designing dielectric resonators on substrates: Combining magnetic and electric resonances
van de Groep, J., & Polman, A. (2013) · Optics Express · doi:10.1364/oe.21.026285 · Cited by 402
Gap plasmon-based metasurfaces for total control of reflected light
Pors, A., Albrektsen, O., Radko, I. P., & Bozhevolnyi, S. I. (2013) · Scientific Reports · doi:10.1038/srep02155 · Cited by 368
Metamaterials and Metasurfaces for Sensor Applications
Lee, Y., Kim, S.-J., Park, H., & Lee, B. (2017) · Sensors · doi:10.3390/s17081726 · Cited by 246
Super-Dispersive Off-Axis Meta-Lenses for Compact High Resolution Spectroscopy
Khorasaninejad, M., Chen, W. T., Oh, J., & Capasso, F. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01097 · Cited by 230
Highly efficient beam steering with a transparent metasurface
Wei, Z., Cao, Y., Su, X., Gong, Z., Long, Y., & Li, H. (2013) · Optics Express · doi:10.1364/oe.21.010739 · Cited by 193
A microsensor for trinitrotoluene vapour
Pinnaduwage, L. A., Gehl, A., Hedden, D. L., Muralidharan, G., Thundat, T., Lareau, R. T., Sulchek, T., Manning, L., Rogers, B., Jones, M., et al. (2003) · Nature · doi:10.1038/425474a · Cited by 189
Highly sensitive biosensors based on all-dielectric nanoresonators
Bontempi, N., Chong, K. E., Orton, H. W., Staude, I., Choi, D.-Y., Alessandri, I., Kivshar, Y. S., & Neshev, D. N. (2017) · Nanoscale · doi:10.1039/c6nr07904k · Cited by 165
Selective Visual Detection of TNT at the Sub‐Zeptomole Level
Mathew, A., Panikkanvalappil, S. R., & Pradeep, T. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201203810 · Cited by 117
Nanoscale beam splitters based on gradient metasurfaces
Zhang, D., Ren, M., Wu, W., Gao, N., Yu, X., Cai, W., Zhang, X., & Xu, J. (2018) · Optics Letters · doi:10.1364/ol.43.000267 · Cited by 91
Huang, H., Chen, S., Liu, F., Zhao, Q., Liao, B., Yi, S., & Zeng, Y. (2013) · Analytical Chemistry · doi:10.1021/ac303305j · Cited by 52
Metadata
- Authors
- Rodionov, S. A., Remnev, M. A., & Klimov, V. V.
- Venue
- Sensing and Bio-Sensing Research
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 22
- Pages
- 100263
- ISSN
- 2214-1804 (ISSN-L)
- OpenAlex
- W2913282644
- Cited by
- 258
- References
- 25
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.