Bionic-structured electromagnetic interference shielding composites
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
As electromagnetic pollution intensifies and the demand for high-precision electronic equipment increases, the development of high-performance, adaptable electromagnetic interference (EMI) shielding materials with high-performance and adaptability has become a research focus. Inspired by natural structures, bionic designs offer unique advantages for the fabrication of advanced EMI shielding materials. These materials provide effective electromagnetic wave attenuation and are lightweight, flexible, and environmentally adaptable, thereby overcoming the limitations of traditional EMI shielding materials. This review systematically summarises the latest advancements in bionic-structured EMI shielding composites. This paper first introduces the design principles of bionic structures and then focuses on typical bioinspired systems, including nacre, honeycomb, leaf vein structures, and other nature-inspired structures. This review further explores common fabrication techniques and the structure-property relationships of materials with such structures, with a particular focus on performance optimisation strategies. Additionally, we examine the conformational relationships and underlying mechanisms governing the performance enhancements of bionic-structured EMI shielding composites. The challenges and future prospects of bionic-structured EMI shielding composites are also analyzed. This review aims to provide theoretical insights into structural innovation and performance enhancement, promoting the application of bionic-structured EMI shielding composites in aerospace, smart wearables, and medical electronics. This paper is expected to pave the way for the development of next-generation electromagnetic protection materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Skeletal muscle: A brief review of structure and function
Frontera, W. R., & Ochala, J. (2015) · Calcified Tissue International · doi:10.1007/s00223-014-9915-y · Cited by 1,758
Metadata
- Authors
- Zhai, M., Zhao, S., Guo, H., Li, X., Shi, X., He, M., Zhang, Y., & Gu, J.
- Venue
- Science Bulletin
- Publisher
- Elsevier BV
- Published
- 2025-07
- Volume
- 70
- Issue
- 14
- Pages
- 2347-2364
- ISSN
- 2095-9273 (ISSN-L)
- OpenAlex
- W4410398688
- Cited by
- 160
- References
- 2
- FWCI
- 25.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bionic-structured electromagnetic interference shielding composites. https://app.cochat.ai/papers/10.1016/j.scib.2025.04.074
- The paper
- Zhai, M., Zhao, S., Guo, H., Li, X., Shi, X., He, M., Zhang, Y., & Gu, J. (2025). Bionic-structured electromagnetic interference shielding composites. Science Bulletin. https://doi.org/10.1016/j.scib.2025.04.074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.