The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Technology review and data analysis for cost assessment of water treatment systems
Abstract
A wide variety of water sources, treatment methods, and recycling options have created a myriad of water management options. For modeling of sustainable water treatment options, computationally efficient models may be required. This paper provides a comprehensive and comparative review of the water management systems and the associated economic, environmental, and performance metrics. The water management systems are represented as a network of sources, users, technologies, recycling options, and quality of water. Special attention is given to desalination systems. The two main technology categories currently used for desalination are thermal (e.g., Multistage Flash "MSF", Multi-Effect Distillation "MED", and Mechanical Vapor Compression "MVC") and membrane (e.g., seawater reverse osmosis "SWRO", brackish water reverse osmosis "BWRO"). The cost assessment includes a capital cost comparison (for which regression analysis has been used to account for the non-linear nature of the capacity-cost curves), an operating cost comparison, which includes energy requirements, labor costs, chemicals used, maintenance and repair costs, membrane replacement costs and a unit product cost ($/m3) breakdown, which combines the capital and operating costs. Numerous data were collected for the cost of desalination systems. Statistical methods were then used to analyze these collected data to establish deeper understanding of the relationship to capital cost, operating cost, capacity, constraints due to treatment method capabilities, requirements of the users. The paper also briefly discusses other cost considerations such as the water intake and distribution costs. The environmental impacts (concentrate disposal and CO2 footprint) have also been compared for the various technologies considered. Some integration strategies such as use of hybrid systems, cogeneration plants and use of renewable energy have shown reductions in cost associated due to energy consumption and thereby, reducing the unit product cost. Finally, the paper provides a selection guide suitable for various situations with consideration of the different factors affecting cost, environmental impact and energy demands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ghaffour, N., Missimer, T. M., & Amy, G. L. (2013) · Desalination · doi:10.1016/j.desal.2012.10.015 · Cited by 1,603
Al-Karaghouli, A., & Kazmerski, L. L. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.12.064 · Cited by 1,274
Cited by
Environmental impact of desalination technologies: A review
Elsaid, K., Kamil, M., Sayed, E. T., Abdelkareem, M. A., Wilberforce, T., & Olabi, A. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141528 · Cited by 550
Robbins, C. A., Du, X., Bradley, T. H., Quinn, J. C., Bandhauer, T. M., Conrad, S. A., Carlson, K. H., & Tong, T. (2022) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2021.106011 · Cited by 36
Metadata
- Authors
- Bhojwani, S., Topolski, K., Mukherjee, R., Sengupta, D., & El-Halwagi, M. M.
- Venue
- Science of The Total Environment
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 651
- Issue
- Pt 2
- Pages
- 2749-2761
- ISSN
- 0048-9697 (ISSN-L)
- OpenAlex
- W2895857089
- Cited by
- 221
- References
- 2
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.