Development of low-cost indoor air quality monitoring devices: Recent advancements
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
The use of low-cost sensor technology to monitor air pollution has made remarkable strides in the last decade. The development of low-cost devices to monitor air quality in indoor environments can be used to understand the behaviour of indoor air pollutants and potentially impact on the reduction of related health impacts. These user-friendly devices are portable, require low-maintenance, and can enable near real-time, continuous monitoring. They can also contribute to citizen science projects and community-driven science. However, low-cost sensors have often been associated with design compromises that hamper data reliability. Moreover, with the rapidly increasing number of studies, projects, and grey literature based on low-cost sensors, information got scattered. Intending to identify and review scientifically validated literature on this topic, this study critically summarizes the recent research pertinent to the development of indoor air quality monitoring devices using low-cost sensors. The method employed for this review was a thorough search of three scientific databases, namely: ScienceDirect, IEEE, and Scopus. A total of 891 titles published since 2012 were found and scanned for relevance. Finally, 41 research articles consisting of 35 unique device development projects were reviewed with a particular emphasis on device development: calibration and performance of sensors, the processor used, data storage and communication, and the availability of real-time remote access of sensor data. The most prominent finding of the study showed a lack of studies consisting of sensor performance as only 16 out of 35 projects performed calibration/validation of sensors. An even fewer number of studies conducted these tests with a reference instrument. Hence, a need for more studies with calibration, credible validation, and standardization of sensor performance and assessment is recommended for subsequent research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Who Regional Office for Europe (2006) · Cited by 1,526
WHO Guidelines for Indoor Air Quality: Selected Pollutants
Who Regional Office for Europe (2011) · Cited by 1,300
The Changing Paradigm of Air Pollution Monitoring
Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R. W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., & Preuss, P. W. (2013) · Environmental Science & Technology · doi:10.1021/es4022602 · Cited by 974
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.04.018 · Cited by 864
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Ali, A. S., Zanzinger, Z., Debose, D., & Stephens, B. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.02.010 · Cited by 233
A Modular IoT Platform for Real-Time Indoor Air Quality Monitoring
Benammar, M., Abdaoui, A., Ahmad, S., Touati, F., & Kadri, A. (2018) · Sensors · doi:10.3390/s18020581 · Cited by 230
Human exposure to ozone in school and office indoor environments
Salonen, H., Salthammer, T., & Morawska, L. (2018) · Environment International · doi:10.1016/j.envint.2018.07.012 · Cited by 218
ISSAQ: An Integrated Sensing Systems for Real-Time Indoor Air Quality Monitoring
Kim, J.-Y., Chu, C.-H., & Shin, S.-M. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2359832 · Cited by 208
Kumar, P., Skouloudis, A. N., Bell, M., Viana, M., Carotta, M. C., Biskos, G., & Morawska, L. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.04.032 · Cited by 201
Children's well-being at schools: Impact of climatic conditions and air pollution
Salthammer, T., Uhde, E., Schripp, T., Schieweck, A., Morawska, L., Mazaheri, M., Clifford, S., He, C., Buonanno, G., Querol, X., et al. (2016) · Environment International · doi:10.1016/j.envint.2016.05.009 · Cited by 198
PortoLivingLab: An IoT-Based Sensing Platform for Smart Cities
Santos, P. M., Queiros, C., Sargento, S., Aguiar, A., Barros, J., Rodrigues, J. G. P., Cruz, S. B., Lourenco, T., d'Orey, P. M., Luis, Y., et al. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2018.2791522 · Cited by 177
Self-citationContinuous IEQ monitoring system: Context and development
Parkinson, T., Parkinson, A., & de Dear, R. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.12.010 · Cited by 174
Peterson, P., Aujla, A., Grant, K., Brundle, A., Thompson, M., Hey, J. V., & Leigh, R. J. (2017) · Sensors · doi:10.3390/s17071653 · Cited by 171
Indoor air quality and energy management through real-time sensing in commercial buildings
Kumar, P., Martani, C., Morawska, L., Norford, L., Choudhary, R., Bell, M., & Leach, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.037 · Cited by 165
New Methods for Personal Exposure Monitoring for Airborne Particles
Koehler, K. A., & Peters, T. M. (2015) · Current Environmental Health Reports · doi:10.1007/s40572-015-0070-z · Cited by 161
Control of CO2 in a naturally ventilated classroom
Griffiths, M., & Eftekhari, M. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.04.013 · Cited by 159
Continuous monitoring of indoor environmental quality using an Arduino-based data acquisition system
Karami, M., McMorrow, G. V., & Wang, L. (2018) · Journal of Building Engineering · doi:10.1016/j.jobe.2018.05.014 · Cited by 158
Martín-Garín, A., Millán-García, J. A., Baïri, A., Millán-Medel, J., & Sala-Lizarraga, J. M. (2018) · Automation in Construction · doi:10.1016/j.autcon.2017.12.017 · Cited by 137
Marques, G., & Pitarma, R. (2019) · Electronics · doi:10.3390/electronics8020170 · Cited by 130
Ostro, B. D., Spadaro, J. V., Gumy, S., Mudu, P., Awe, Y., Forastiere, F., & Peters, A. (2018) · Environmental Research · doi:10.1016/j.envres.2018.03.001 · Cited by 121
Design and Development of a Low-Cost, Portable Monitoring Device for Indoor Environment Quality
Tiele, A., Esfahani, S., & Covington, J. A. (2018) · Journal of Sensors · doi:10.1155/2018/5353816 · Cited by 104
Quantifying indoor air quality determinants in urban and rural nursery and primary schools
Branco, P. T. B. S., Alvim-Ferraz, M. C. M., Martins, F. G., & Sousa, S. I. V. (2019) · Environmental Research · doi:10.1016/j.envres.2019.108534 · Cited by 99
Self-citationIndoor Air Pollution Related Respiratory Ill Health, a Sequel of Biomass Use
Mulenga, D., & Siziya, S. (2019) · SciMedicine Journal · doi:10.28991/scimedj-2019-0101-5 · Cited by 96
Salamone, F., Belussi, L., Danza, L., Ghellere, M., & Meroni, I. (2015) · Sensors · doi:10.3390/s150613012 · Cited by 79
Continuous IEQ monitoring system: Performance specifications and thermal comfort classification
Parkinson, T., Parkinson, A., & de Dear, R. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.12.016 · Cited by 79
Gillooly, S. E., Zhou, Y., Vallarino, J., Chu, M. T., Michanowicz, D. R., Levy, J. I., & Adamkiewicz, G. (2018) · Environmental Pollution · doi:10.1016/j.envpol.2018.10.064 · Cited by 70
Outdoor/Indoor/Personal Ozone Exposures of Children in Nashville, Tennessee
Lee, K., Parkhurst, W. J., Xue, J., Özkaynak, H., Neuberg, D. S., & Spengler, J. D. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10470904 · Cited by 68
Particulate matter in rural and urban nursery schools in Portugal
Nunes, R. A. O., Branco, P. T. B. S., Alvim-Ferraz, M. C. M., Martins, F. G., & Sousa, S. I. V. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.03.009 · Cited by 65
Self-citationYang, C., Liao, C.-J., Liu, J., Den, W., Chou, Y., & Tsai, J.-J. (2014) · Journal of Medical Systems · doi:10.1007/s10916-014-0015-3 · Cited by 59
Salamone, F., Danza, L., Meroni, I., & Pollastro, M. (2017) · Sensors · doi:10.3390/s17040828 · Cited by 59
POVOMON: An Ad-hoc Wireless Sensor Network for indoor environmental monitoring
Brunelli, D., Minakov, I., Passerone, R., & Rossi, M. (2014) · IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) · doi:10.1109/eesms.2014.6923287 · Cited by 55
Design of A Low-Cost Wireless Indoor Air Quality Sensor Network System
Abraham, S., & Li, X. (2016) · International Journal of Wireless Information Networks · doi:10.1007/s10776-016-0299-y · Cited by 52
Children's exposure to indoor air in urban nurseries – Part II: Gaseous pollutants' assessment
Branco, P. T. B. S., Nunes, R. A. O., Alvim-Ferraz, M. C. M., Martins, F. G., & Sousa, S. I. V. (2015) · Environmental Research · doi:10.1016/j.envres.2015.08.026 · Cited by 52
Self-citation2017 IEEE Sensors Applications Symposium (SAS)
(2017) · doi:10.1109/sas39909.2017 · Cited by 37
EMI-Free Bidirectional Real-Time Indoor Environment Monitoring System
Pham, N. Q., Rachim, V. P., & Chung, W.-Y. (2018) · IEEE Access · doi:10.1109/access.2018.2889793 · Cited by 31
A wireless system for indoor air quality monitoring
du Plessis, R., Kumar, A., Hancke, G. P., & Silva, B. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7794087 · Cited by 30
Smart building monitoring from structure to indoor environment
Včelák, J., Vodicka, A., Maska, M., & Mrna, J. (2017) · Smart City Symposium Prague (SCSP) · doi:10.1109/scsp.2017.7973859 · Cited by 30
2016 Smart Cities Symposium Prague (SCSP)
(2016) · doi:10.1109/scsp39346.2016 · Cited by 28
Air-kare: A Wi-Fi based, multi-sensor, real-time indoor air quality monitor
Yang, Q., Zhou, G., Qin, W., Zhang, B., & Chiang, P. Y. (2015) · IEEE International Wireless Symposium · doi:10.1109/ieee-iws.2015.7164542 · Cited by 23
Cloud-based smart device for environment monitoring
Jiang, B., & Huacon, C. F. (2017) · IEEE Conference on Technologies for Sustainability · doi:10.1109/sustech.2017.8333472 · Cited by 18
Scarpa, M., Ravagnin, R., Schibuola, L., & Tambani, C. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.08.155 · Cited by 18
Personal Environmental Monitoring System and network platform
Cho, H. (2015) · International Conference on Sensing Technology · doi:10.1109/icsenst.2015.7438496 · Cited by 17
Indoor PM10 and PM2.5 at Nurseries and Primary Schools
Siv, S., Alvim-Ferraz, M. C. M., & Martins, F. G. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.433-440.385 · Cited by 16
Self-citationSalamone, F., Belussi, L., Danza, L., Ghellere, M., & Meroni, I. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.11.148 · Cited by 16
On detecting acceptable air contamination in classrooms using low cost sensors
Sharma, P. K., Poddar, B., Dey, S., Nandi, S., De, T., Saha, M., Mondal, S., & Saha, S. (2017) · International Conference on Communication Systems & Networks (COMSNETS) · doi:10.1109/comsnets.2017.7945439 · Cited by 12
Metadata
- Authors
- Chojer, H., Branco, P. T. B. S., Martins, F. G., Alvim-Ferraz, M. C. M., & Sousa, S. I. V.
- Venue
- Science of The Total Environment
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 727
- Pages
- 138385
- ISSN
- 0048-9697 (ISSN-L)
- OpenAlex
- W3015224255
- Cited by
- 218
- References
- 53
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.