Long-term investigation on the removal of perfluoroalkyl substances in a full-scale drinking water treatment plant in the Veneto Region, Italy
Abstract
Drinking water contamination by perfluoroalkyl and polyfluoroalkyl substances (PFASs) is an issue of relatively recent concern. The literature indicates that anion exchange resins and granular activated carbon (GAC) are suitable technologies for removing these compounds. While several laboratory-scale and pilot-scale experiments have been conducted to study activated carbon adsorption/desorption mechanisms of a number of PFASs, little data on full-scale plants are available. This work examines a real case of groundwater contamination by PFASs in an area of approximately 200 km 2. The performance of the main drinking water treatment plant in the area (flowrate = 30,000 m 3/d; 100,000 people served), which is equipped with GAC filters, was analysed. Approximately 17,000 analytical data points from a working period of five years were processed. Perfluorobutyric acid (PFBA) was the first compound to attain breakthrough, followed by perfluoropentanoic acid, perfluorohexanoic acid, perfluorobutanesulfonic acid, and perfluorooctanoic acid (PFOA). The adsorption capacity and treated bed volumes at complete breakthrough (saturation) were calculated, and ranged from 1.71 g/t and 7100 (PFBA) to 24.6 g/t and 50,900 (PFOA), with the total organic carbon concentration in the groundwater ranging from <0.1 to 0.5 mg/L. The overall adsorption capacity was approximately 40 g of total PFASs/t. The breakthrough behaviour of PFASs was correlated with the CF chain length, the type of hydrophilic head (either carboxyl or sulfonic), and the n-octanol/water partition coefficients logP and logD. The results corroborate the findings of previously published bench-scale and pilot-scale experiments.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For a DWTP with rapid sand filtration, granular activated carbon adsorption, and disinfection (NaClO) treating groundwater, the overall adsorption capacity was about 40 g of total PFAS/t.
“The overall adsorption capacity of about 40 g of total PFAS/t”
From A Mini-Review of Full-Scale Drinking Water Treatment Plants for Per- and Polyfluoroalkyl Substances (PFAS) Removal: Possible Solutions and Future Directions (2025) · cites this paper as Bertanza et al. [40]
Cites
Adsorption behavior and mechanism of perfluorinated compounds on various adsorbents—A review
Du, Z., Deng, S., Bei, Y., Huang, Q., Wang, B., Huang, J., & Yu, G. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.04.038 · Cited by 1,236 · see citing works
Microbial degradation of polyfluoroalkyl chemicals in the environment: A review
Liu, J., & Mejia Avendaño, S. (2013) · Environment International · doi:10.1016/j.envint.2013.08.022 · Cited by 525 · see citing works
Zaggia, A., Conte, L., Falletti, L., Fant, M., & Chiorboli, A. (2016) · Water Research · doi:10.1016/j.watres.2015.12.039 · Cited by 410 · see citing works
Crone, B. C., Speth, T. F., Wahman, D. G., Smith, S. J., Abulikemu, G., Kleiner, E. J., & Pressman, J. G. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2019.1614848 · Cited by 408 · see citing works
Eschauzier, C., Beerendonk, E., Scholte-Veenendaal, P., & De Voogt, P. (2012) · Environmental Science & Technology · doi:10.1021/es201662b · Cited by 318 · see citing works
Sorption of perfluorinated compounds from contaminated water to activated carbon
Hansen, M. C., Børresen, M. H., Schlabach, M., & Cornelissen, G. (2010) · Journal of Soils and Sediments · doi:10.1007/s11368-009-0172-z · Cited by 175 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Jafarinejad, S. (2025) · Sustainability · doi:10.3390/su17020451 · Cited by 27 · see citing works
- Authors
- Bertanza, G., Capoferri, G. U., Carmagnani, M., Icarelli, F., Sorlini, S., & Pedrazzani, R.
- Affiliations
- University of Brescia (IT)
- Corresponding author
- Pedrazzani, Roberta
- Venue
- Science of The Total Environment
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 734
- Pages
- 139154
- ISSN
- 0048-9697 (ISSN-L)
- OpenAlex
- W3021076681
- Cited by
- 38
- References
- 6
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 7 · 2023: 7 · 2022: 5 · 2021: 5 · 2020: 2
- FWCI
- 1.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Science of The Total Environment (publishedVersion)
- PubMed (publishedVersion)
- Institutional Research Information System (Università degli Studi di Brescia) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
- Physical Sciences › Environmental Science › Water Science and Technology › Fluoride Effects and Removal
- Keywords
- per- and polyfluoroalkyl substances, PFAS removal, drinking water treatment, granular activated carbon, groundwater contamination, adsorption capacity, breakthrough, perfluorooctanoic acid, perfluorobutanoic acid, PFBS, PFPeA, perfluorohexanoic acid, octanol-water partition coefficient, chain length effects, full-scale treatment plant
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review