Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 234

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Microplastic distributions in a domestic wastewater treatment plant: Removal efficiency, seasonal variation and influence of sampling technique

Open access
Ben-David, Eric A., Habibi, Maryana, Haddad, Elias, Hasanin, Mahdi, Angel, Dror L., Booth, Andy M., Sabbah, Isam · 2021 · Science of The Total Environment

Abstract

Wastewater treatment plants (WWTPs) serve as an important route of microplastics (MPs) to the environment. Therefore, more effective MPs sampling and detection methodologies, as well as a better understanding of their influence on MPs occurrence and distributions in WWTP effluents, are needed for better removal and control. In this work, the efficiency of a municipal WWTP to remove MPs was assessed by collecting samples from raw to tertiary effluent during a 12-month sampling campaign (season-based) using different sampling methods (containers, 24-h composite and large grab samples). MPs retrieved from different treatment units within the WWTP were identified and quantified using plastic/non-plastic staining followed by optical microscopy, SEM and μ-Raman microscopy. Overall, the mean removal efficiency of MPs in the WWTP was 97%, with most MPs removed by the secondary stage and a mean effluent concentration of 1.97 MPs L-1 after sand filtration. The relative abundance of particles was lower than fibers in treated effluent compared with the raw wastewater, with MP fibers constituting 74% of the total MPs in raw wastewater and 91% in treated effluent. Taking seasonal variations into account is important as total MPs concentration in the effluent was notably higher in winter compared with the other seasons. Increasing the sampled volume using large samples or 24-h composite samples significantly reduced the variability between replicates. However, MPs concentration post the tertiary stage was significantly lower using morning sampling (9 am) by large grab sampling method (1.2 MPs L-1) compared to 24-h composite sampling (3.2 MPs L-1) possibly due to intra-daily changes. Using a finer mesh size (0.45 μm) to capture MPs beyond the size range typically studied (≥20 μm) effectively doubled the number of MPs detected in the tertiary effluent and highlights the importance of standardizing sampling procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.scitotenv.2020.141880

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 234

Metadata

Authors
Ben-David, E. A., Habibi, M., Haddad, E., Hasanin, M., Angel, D. L., Booth, A. M., & Sabbah, I.
Venue
Science of The Total Environment
Publisher
Elsevier BV
Published
2021-01
Volume
752
Pages
141880
ISSN
0048-9697 (ISSN-L)
OpenAlex
W3080463522
Cited by
234
References
5
FWCI
6.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microplastic distributions in a domestic wastewater treatment plant: Removal efficiency, seasonal variation and influence of sampling technique. https://app.cochat.ai/papers/10.1016/j.scitotenv.2020.141880
The paper
Ben-David, E. A., Habibi, M., Haddad, E., Hasanin, M., Angel, D. L., Booth, A. M., & Sabbah, I. (2021). Microplastic distributions in a domestic wastewater treatment plant: Removal efficiency, seasonal variation and influence of sampling technique. Science of The Total Environment. https://doi.org/10.1016/j.scitotenv.2020.141880

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.