CoChat
Cited by 166

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Improved-salp swarm optimized type-II fuzzy controller in load frequency control of multi area islanded AC microgrid

Sahu, Prakash Chandra, Mishra, Sonalika, Prusty, Ramesh Chandra, Panda, Sidhartha · 2018 · Sustainable Energy, Grids and Networks

Abstract

The present article deals with load frequency control (LFC) in an islanded two area AC microgrid (MC) system. In this study the proposed two area MG system comprises different micro sources including Micro-turbine (MT), Diesel engine generator (DEG) and Fuel Cells (FC) which are primarily responsible for balancing load and power generation in an interconnected system. MG in grid-connected mode has lower possibility of frequency control problem due to active presence of utility grid. Whereas MG in islanded mode faces huge frequency control problem due to dynamic nature of different renewable energy sources (RES) and different uncertainties like wind power fluctuations, disturbances in solar irradiation power, dynamics in applied load and system parameters (damping coefficient & Inertia constant). In regard to this the present article proposes a robust type-II fuzzy PID controller to create secondary frequency control loop for maintaining both frequency and tie-line power to their nominal values under different uncertainties. For performance study, the proposed type-II fuzzy PID controller performances are compared with type-I fuzzy controller, PID and PI controllers. To obtain optimal gain values of above controllers, a meta-heuristic improved-salp swarm optimization (I-SSO) algorithm has been implemented and proposed I-SSO technique performances are compared with original SSO, Particle swarm optimization (PSO) and Genetic Algorithm (GA) techniques. Finally it is observed from different performance analysis that proposed I-SSO tuned type-II fuzzy controller exhibits superior performances for load frequency control in multi-area islanded AC microgrid system under different uncertainty conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.segan.2018.10.003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Trends in Microgrid Control

    Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137

Cited by

See all 166

Metadata

Authors
Sahu, P. C., Mishra, S., Prusty, R. C., & Panda, S.
Venue
Sustainable Energy, Grids and Networks
Publisher
Elsevier BV
Published
2018-12
Volume
16
Pages
380-392
ISSN
2352-4677 (ISSN-L)
OpenAlex
W2900271993
Cited by
166
References
1
FWCI
5.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.