Scoring accuracy of automated sleep staging from a bipolar electroocular recording compared to manual scoring by multiple raters
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Electroencephalography (EEG) assessment in research and clinical studies is limited by the patient burden of multiple electrodes and the time needed to manually score records. The objective of our study was to investigate the accuracy of an automated sleep-staging algorithm which is based on a single bipolar EEG signal. METHODS: Three raters each manually scored the polysomnographic (PSG) records from 44 patients referred for sleep evaluation. Twenty-one PSG records were scored by Rechtschaffen and Kales (R&K) criteria (group 1) and 23 PSGs were scored by American Academy of Sleep Medicine (AASM) 2007 criteria (group 2). Majority agreement was present in 98.4% of epochs and was used for comparison to automated scoring from a single EEG lead derived from the left and right electrooculogram. RESULTS: The κ coefficients for interrater manual scoring ranged from 0.46 to 0.89. The κ coefficient for the auto algorithm vs manual scoring by rater ranged from 0.42 to 0.63 and was 0.61 (group 1, κ=0.61 and group 2, κ=0.62) for majority agreement for all studies. The mean positive percent agreement across subjects and stages was 72.6%, approximately 80% for stages wake (78.3%), stage 2 sleep (N2) (80.9%), and stage 3 sleep (N3) (78.1%); the percentage slightly decreased to 73.2% for rapid eye movement (REM) sleep and dropped to 31.9% for stage 1 sleep (N1). Differences in agreement were observed based on raters, obstructive sleep apnea (OSA) severity, medications, and signal quality. CONCLUSIONS: Our study demonstrated that automated scoring of sleep obtained from a single-channel of forehead EEG results in agreement to majority manual scoring are similar to results obtained from studies of manual interrater agreement. The benefit in assessing auto-staging accuracy with consensus agreement across multiple raters is most apparent in patients with OSA; additionally, assessing auto-staging accuracy limited disagreements in patients on medications and in those with compromised signal quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adult Obstructive Sleep Apnea Task Force of the American Academy of Sleep Medicine, Epstein, L. J., Kristo, D., Strollo, P. J., Friedman, N., Malhotra, A., Patil, S. P., Ramar, K., Rogers, R., Schwab, R. J., et al. (2009) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27497 · Cited by 3,360
The visual scoring of sleep in adults
Silber, M. H., Ancoli-Israel, S., Bonnet, M. H., Chokroverty, S., Grigg-Damberger, M. M., Hirshkowitz, M., Kapen, S., Keenan, S. A., Kryger, M. H., Penzel, T., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26814 · Cited by 1,064 · cited 1×
“Part of the issue with scoring N1 is the difficulty in identifying the transition from wake to N1, which may in part be explained by the finding that upwards of 20% of the general population generate little or no alpha [12].”
BackgroundDANKER‐HOPFE, H., ANDERER, P., ZEITLHOFER, J., BOECK, M., DORN, H., GRUBER, G., HELLER, E., LORETZ, E., MOSER, D., PARAPATICS, S., et al. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00700.x · Cited by 417
Cited by
A convolutional neural network for sleep stage scoring from raw single-channel EEG
Sors, A., Bonnet, S., Mirek, S., Vercueil, L., & Payen, J.-F. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.12.001 · Cited by 424
ISRUC-Sleep: A comprehensive public dataset for sleep researchers
Khalighi, S., Sousa, T., Santos, J. M., & Nunes, U. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.10.013 · Cited by 367
Automatic Sleep Stage Scoring Using Time-Frequency Analysis and Stacked Sparse Autoencoders
Tsinalis, O., Matthews, P. M., & Guo, Y. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1444-y · Cited by 322
A comparative review on sleep stage classification methods in patients and healthy individuals
Boostani, R., Karimzadeh, F., & Nami, M. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.12.004 · Cited by 316
Mixed Neural Network Approach for Temporal Sleep Stage Classification
Dong, H., Supratak, A., Pan, W., Wu, C., Matthews, P. M., & Guo, Y. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2733220 · Cited by 295
Automated sleep scoring: A review of the latest approaches
Fiorillo, L., Puiatti, A., Papandrea, M., Ratti, P.-L., Favaro, P., Roth, C., Bargiotas, P., Bassetti, C. L., & Faraci, F. D. (2019) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2019.07.007 · Cited by 284
Seo, H., Back, S., Lee, S., Park, D., Kim, T., & Lee, K. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102037 · Cited by 237
Comparison of a single‐channel EEG sleep study to polysomnography
Lucey, B. P., Mcleland, J. S., Toedebusch, C. D., Boyd, J., Morris, J. C., Landsness, E. C., Yamada, K., & Holtzman, D. M. (2016) · Journal of Sleep Research · doi:10.1111/jsr.12417 · Cited by 158
Zero-Effort In-Home Sleep and Insomnia Monitoring using Radio Signals
Hsu, C.-Y., Ahuja, A., Yue, S., Hristov, R., Kabelac, Z., & Katabi, D. (2017) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3130924 · Cited by 97
“Out of these, all subjects slept with SleepProfiler [1, 43], which is an FDA-approved medical grade sleep monitoring device, for a total of 30 nights to obtain the ground truth for our sleep parameters.”
BackgroundFinan, P. H., Richards, J. M., Gamaldo, C. E., Han, D., Leoutsakos, J. M., Salas, R., Irwin, M. R., & Smith, M. T. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6262 · Cited by 90
“The automatic scoring algorithm (SP Auto) was guided by general staging rules consistent with the AASM scoring rules,8 with the following exceptions: (1) Four consecutive non-wake epochs are necessary to identify sleep onset in the first 5 minutes of recording; (2) If a wake period is identified within a block of REM…”
Method
Metadata
- Authors
- Stepnowsky, C., Levendowski, D., Popovic, D., Ayappa, I., & Rapoport, D. M.
- Venue
- Sleep Medicine
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 14
- Issue
- 11
- Pages
- 1199-1207
- ISSN
- 1389-9457 (ISSN-L)
- OpenAlex
- W2066799036
- Cited by
- 115
- References
- 3
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.