Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Comparison of a single‐channel EEG sleep study to polysomnography

Open access
Lucey, Brendan P., Mcleland, Jennifer S., Toedebusch, Cristina D., Boyd, Jill, Morris, John C., Landsness, Eric C., Yamada, Kelvin, Holtzman, David M. · 2016 · Journal of Sleep Research

Abstract

Summary: An accurate home sleep study to assess electroencephalography (EEG)‐based sleep stages and EEG power would be advantageous for both clinical and research purposes, such as for longitudinal studies measuring changes in sleep stages over time. The purpose of this study was to compare sleep scoring of a single‐channel EEG recorded simultaneously on the forehead against attended polysomnography. Participants were recruited from both a clinical sleep centre and a longitudinal research study investigating cognitively normal ageing and Alzheimer's disease. Analysis for overall epoch‐by‐epoch agreement found strong and substantial agreement between the single‐channel EEG compared to polysomnography (κ = 0.67). Slow wave activity in the frontal regions was also similar when comparing the single‐channel EEG device to polysomnography. As expected, Stage N1 showed poor agreement (sensitivity 0.2) due to lack of occipital electrodes. Other sleep parameters, such as sleep latency and rapid eye movement (REM) onset latency, had decreased agreement. Participants with disrupted sleep consolidation, such as from obstructive sleep apnea, also had poor agreement. We suspect that disagreement in sleep parameters between the single‐channel EEG and polysomnography is due partially to altered waveform morphology and/or poorer signal quality in the single‐channel derivation. Our results show that single‐channel EEG provides comparable results to polysomnography in assessing REM, combined Stages N2 and N3 sleep and several other parameters, including frontal slow wave activity. The data establish that single‐channel EEG can be a useful research tool.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jsr.12417

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 158

Metadata

Authors
Lucey, B. P., Mcleland, J. S., Toedebusch, C. D., Boyd, J., Morris, J. C., Landsness, E. C., Yamada, K., & Holtzman, D. M.
Venue
Journal of Sleep Research
Publisher
Wiley
Published
2016-06-02
Volume
25
Issue
6
Pages
625-635
ISSN
  • 0962-1105 (ISSN-L)
  • 1365-2869
OpenAlex
W2418216612
Cited by
158
References
7
FWCI
15.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of a single‐channel EEG sleep study to polysomnography. https://app.cochat.ai/papers/10.1111/jsr.12417
The paper
Lucey, B. P., Mcleland, J. S., Toedebusch, C. D., Boyd, J., Morris, J. C., Landsness, E. C., Yamada, K., & Holtzman, D. M. (2016). Comparison of a single‐channel EEG sleep study to polysomnography. Journal of Sleep Research. https://doi.org/10.1111/jsr.12417

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.