CoChat
Cited by 218

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

World Association of Sleep Medicine (WASM) 2016 standards for recording and scoring leg movements in polysomnograms developed by a joint task force from the International and the European Restless Legs Syndrome Study Groups (IRLSSG and EURLSSG)

Open access
Ferri, R., Fulda, S., Allen, R.P., Zucconi, M., Bruni, O., Chokroverty, S., Ferini-Strambi, L., Frauscher, B., Garcia-Borreguero, D., Hirshkowitz, M., Högl, B., Inoue, Y., Jahangir, A., Manconi, M., Marcus, C.L., Picchietti, D.L., Plazzi, G., Winkelman, J.W., Zak, R.S. · 2016 · Sleep Medicine

Abstract

This report presents the results of the work by a joint task force of the International and European Restless Legs Syndrome Study Groups and World Association of Sleep Medicine that revised and updated the current standards for recording and scoring leg movements (LM) in polysomnographic recordings (PSG). First, the background of the decisions made and the explanations of the new rules are reported and then specific standard rules are presented for recording, detecting, scoring and reporting LM activity in PSG. Each standard rule has been classified with a level of evidence. At the end of the paper, Appendix 1 provides algorithms to aid implementation of these new standards in software tools. There are two main changes introduced by these new rules: 1) Candidate LM (CLM), are any monolateral LM 0.5-10 s long or bilateral LM 0.5-15 s long; 2) periodic LM (PLM) are now defined by runs of at least four consecutive CLM with an intermovement interval ≥10 and ≤ 90 s without any CLM preceded by an interval <10 s interrupting the PLM series. There are also new options defining CLM associated with respiratory events. The PLM rate may now first be determined for all CLM not excluding any related to respiration (providing a consistent number across studies regardless of the rules used to define association with respiration) and, subsequently, the PLM rate should also be calculated without considering the respiratory related events. Finally, special considerations for pediatric studies are provided. The expert visual scoringof LM has only been altered by the new standards to require accepting all LM > 0.5 s regardless of duration, otherwise the technician scores the LM as for the old standards. There is a new criterion for the morphology of LM that applies only to computerized LM detection to better match expert visual detection. Available automatic scoring programs will incorporate all the new rules so that the new standards should reduce technician burden for scoring PLMS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.sleep.2016.10.010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Ferri, R., Fulda, S., Allen, R. P., Zucconi, M., Bruni, O., Chokroverty, S., Ferini-Strambi, L., Frauscher, B., Garcia-Borreguero, D., Hirshkowitz, M., Högl, B., Inoue, Y., Jahangir, A., Manconi, M., Marcus, C. L., Picchietti, D. L., Plazzi, G., Winkelman, J. W., & Zak, R. S.
Venue
Sleep Medicine
Publisher
Elsevier BV
Published
2016-10
Volume
26
Pages
86-95
ISSN
1389-9457 (ISSN-L)
OpenAlex
W2550538392
Cited by
218
References
1
FWCI
13.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.