In-use calibration of body-mounted gyroscopes for applications in gait analysis
Open accessThe DOI matches its Crossref record.
Abstract
In this paper, we propose an in-use calibration procedure for gyroscopes. The case report is a simple inertial measurement unit (IMU), which is used in our current research on inertial motion-sensing for advanced footware. The IMU contains two biaxial accelerometers and one gyroscope; it is developed for being mounted on one subject's foot instep, with the aim to reconstruct the trajectory in the sagittal plane of the sensed anatomical point. Since the IMU sagittal displacements can be estimated by performing strapdown integration, they can also be compared with their true values. One movement, which corresponds to known (vertical) displacements, consists of foot placements from the ground level on to top of steps of known height (step climbing). Provided that the IMU accelerometers are calibrated separately by any standard calibration procedure, motion tracking during the stepping movement allows to estimate the gyroscope sensitivity. The experimental results we present in this paper demonstrate the proposed in-use calibration procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349
Self-citationOptimization of IMU sensor placement for the measurement of lower limb joint kinematics
Niswander, W., Wang, W., & Kontson, K. (2020) · Sensors · doi:10.3390/s20215993 · Cited by 116
“Foot Dorsal foot 13 * Laudanski 2013 [19], Panebianco 2018 [10], Barrois 2016 [20], Vargas-Valencia 2016 [26], Bourgeois 2014 [27], Guo 2012 [28], Hsu 2014 [29], Tadano 2013 [30], Kong 2013 [16], Scapellato 2005 [31], Kwakkel 2007 [17], Anwary 2018 [11]”
Bergmann, J. H., Mayagoitia, R. E., & Smith, I. C. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-3 · Cited by 88
“Although, a miniature gyroscope attached to the shank is able to detect different cycles during stair ascent [15] and position data of the foot can be gathered with the combination of a gyroscope and two accelerometers [16], a portable system that can collect anatomical joint angles during stair climbing has not yet b…”
Background
Metadata
- Authors
- Scapellato, S., Cavallo, F., Martelloni, C., & Sabatini, A. M.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2005-09
- Volume
- 123-124
- Pages
- 418-422
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W1995598724
- Cited by
- 45
- References
- 0
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-use calibration of body-mounted gyroscopes for applications in gait analysis. https://app.cochat.ai/papers/10.1016/j.sna.2005.03.052
- The paper
- Scapellato, S., Cavallo, F., Martelloni, C., & Sabatini, A. M. (2005). In-use calibration of body-mounted gyroscopes for applications in gait analysis. Sensors and Actuators A: Physical. https://doi.org/10.1016/j.sna.2005.03.052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.