A wafer-scale etching technique for high aspect ratio implantable MEMS structures

Open access
Bhandari, R., Negi, S., Rieth, L., Solzbacher, F.·2010·Sensors and Actuators A: Physical

Abstract

Microsystem technology is well suited to batch fabricate microelectrode arrays, such as the Utah electrode array (UEA), intended for recording and stimulating neural tissue. Fabrication of the UEA is primarily based on the use of dicing and wet etching to achieve high aspect ratio (15:1) penetrating electrodes. An important step in the array fabrication is the etching of electrodes to produce needle-shape electrodes with sharp tips. Traditional etching processes are performed on a single array, and the etching conditions are not optimized. As a result, the process leads to variable geometries of electrodes within an array. Furthermore, the process is not only time consuming but also labor-intensive. This report presents a wafer-scale etching method for the UEA. The method offers several advantages, such as substantial reduction in the processing time, higher throughput and lower cost. More importantly, the method increases the geometrical uniformity from electrode to electrode within an array (1.5 ± 0.5 % non-uniformity), and from array to array within a wafer (2 ± 0.3 % non-uniformity). Also, the etching rate of silicon columns, produced by dicing, are studied as a function of temperature, etching time and stirring rate in a nitric acid rich HF-HNO(3) solution. These parameters were found to be related to the etching rates over the ranges studied and more-importantly affect the uniformity of the etched silicon columns. An optimum etching condition was established to achieve uniform shape electrode arrays on wafer-scale.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.sna.2010.06.011

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 23 · Cited by 71

Research works printed but not linked: 1

  1. [10]Bhandari R Negi S Reith L Solzbacher F Wafer-scale Processed, Low Impedance Neural Arrays with Variable Length Microelectrodes to appear in Proceedings of Transducers ’09 Denver, USA June 21-25, 2009

Authors
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F.
Affiliations
University of Utah (US)
Corresponding author
Bhandari, R.
Venue
Sensors and Actuators A: Physical
Publisher
Elsevier BV
Published
2010-07
Volume
162
Issue
1
Pages
130-136
ISSN
0924-4247 (ISSN-L)
OpenAlex
W1974894886
Cited by
71
References
23
Citations by year
2026: 3 · 2025: 4 · 2024: 3 · 2023: 3 · 2022: 4 · 2021: 1 · 2020: 4 · 2019: 8 · 2018: 8 · 2017: 4 · 2016: 4 · 2015: 3 · 2014: 9 · 2013: 3 · 2012: 6
FWCI
3.03
Type
journal article
Language
en
Open access
Locations
  • Sensors and Actuators A Physical (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Neurological Disorders and Stroke (HHSN265200423621C)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
Utah electrode array, high aspect ratio electrodes, neural recording electrodes, neural stimulation electrodes, etch rate, batch fabrication, MEMS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›