A compact dosimetric system for MOSFETs based on passive NFC tag and smartphone
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this work we describe and evaluate a dosimetric system based on an NFC (Near Field Communication) tag and a smartphone that uses commercial MOSFETs as radiation sensors. The tag is designed with commercial integrated circuits and the smartphone is the power source of the tag configured as a readout unit, user interface and storage unit. The NFC tag is supplied wirelessly by the smartphone via NFC, using a home-made structure to align the tag coil and smartphone coil in order to achieve a good inductive coupling. In this case, the commercial DMOS transistor ZVP3306 is used as dosimeter in unbiased mode, connected to the tag before and after each irradiation session to perform the sensor reading. An evaluation of the dosimetric system has been carried out irradiating three transistors with photon beam of 6 MV up to 20 Gy. The average sensitivity found is (4.75 ± 0.15) mV/Gy, which is in good agreement with the results found with our previously developed dosimetric system. Therefore, this miniaturised dosimetric system can be considered as a promising and low cost electronic architecture to be used for dosimetry control in radio-therapy treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
Metadata
- Authors
- Carvajal, M. A., Escobedo, P., Jiménez-Melguizo, M., Martínez-García, M. S., Martínez-Martí, F., Martínez-Olmos, A., & Palma, A. J.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 267
- Pages
- 82-89
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2762882090
- Cited by
- 208
- References
- 2
- FWCI
- 0.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A compact dosimetric system for MOSFETs based on passive NFC tag and smartphone. https://app.cochat.ai/papers/10.1016/j.sna.2017.10.015
- The paper
- Carvajal, M. A., Escobedo, P., Jiménez-Melguizo, M., Martínez-García, M. S., Martínez-Martí, F., Martínez-Olmos, A., & Palma, A. J. (2017). A compact dosimetric system for MOSFETs based on passive NFC tag and smartphone. Sensors and Actuators A: Physical. https://doi.org/10.1016/j.sna.2017.10.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.