The DOI matches its Crossref record.
Cholesterol biosensor based on cholesterol esterase, cholesterol oxidase and peroxidase immobilized onto conducting polyaniline films
Open accessAbstract
Cholesterol oxidase, cholesterol esterase and peroxidase have been co-immobilized onto electrochemically prepared polyaniline films. These polyaniline–enzyme films characterized using spectroscopic techniques, have been used to fabricate a cholesterol biosensor. This polyaniline-based cholesterol biosensor has a response time of about 240 s, an apparent Km value as 75 mg dl−1 and can be used to estimate cholesterol concentration up to 500 mg dl−1. These polyaniline/cholesterol oxidase/cholesterol esterase films have a detection limit of 25 mg dl−1 with sensitivity of 0.042 μA mg dl−1. The enzyme films were found to be thermally stable up to 48 °C and have a shelf-life of about 6 weeks when stored at 4 °C. The values of the activation energy before and after the critical temperature were found to be 191 and 95.5 kJ mol−1, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
A Nanostructured Conductive Hydrogels-Based Biosensor Platform for Human Metabolite Detection
Li, L., Wang, Y., Pan, L., Shi, Y., Cheng, W., Shi, Y., & Yu, G. (2015) · Nano Letters · doi:10.1021/nl504217p · Cited by 422
Prospects of conducting polymers in biosensors
Malhotra, B. D., Chaubey, A., & Singh, S. P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.055 · Cited by 372
Self-citationRecent advances in cholesterol biosensor
Arya, S. K., Datta, M., & Malhotra, B. D. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.10.018 · Cited by 262
Self-citation
Metadata
- Authors
- Singh, S., Solanki, P. R., Pandey, M. K., & Malhotra, B. D.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2006-05
- Volume
- 115
- Issue
- 1
- Pages
- 534-541
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W1983226956
- Cited by
- 206
- References
- 0
- FWCI
- 9.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cholesterol biosensor based on cholesterol esterase, cholesterol oxidase and peroxidase immobilized onto conducting polyaniline films. https://app.cochat.ai/papers/10.1016/j.snb.2005.10.025
- The paper
- Singh, S., Solanki, P. R., Pandey, M. K., & Malhotra, B. D. (2006). Cholesterol biosensor based on cholesterol esterase, cholesterol oxidase and peroxidase immobilized onto conducting polyaniline films. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2005.10.025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.