The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
A Nanostructured Conductive Hydrogels-Based Biosensor Platform for Human Metabolite Detection
Abstract
The development of a scalable, low-cost, and versatile biosensor platform for the sensitive and rapid detection of human metabolites is of great interest for healthcare, pharmaceuticals, and medical science. On the basis of hierarchically nanostructured conducting polymer hydrogels, we designed a flexible biosensor platform that can detect various human metabolites, such as uric acid, cholesterol, and triglycerides. Owing to the unique features of conducting polymer hydrogels, such as high permeability to biosubstrates and rapid electron transfer, our biosensors demonstrate excellent sensing performance with a wide linear range (uric acid, 0.07-1 mM; cholesterol, 0.3-9 mM, and triglycerides, 0.2-5 mM), high sensitivity, low sensing limit, and rapid response time (∼3 s). Given the facile and scalable processability of hydrogels, the proposed conductive hydrogels-based biosensor platform shows great promise as a low-cost sensor kit for healthcare monitoring, clinical diagnostics, and biomedical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Application of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,652
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Self-citationHighly Sensitive Glucose Sensor Based on Pt Nanoparticle/Polyaniline Hydrogel Heterostructures
Zhai, D., Liu, B., Shi, Y., Pan, L., Wang, Y., Li, W., Zhang, R., & Yu, G. (2013) · ACS Nano · doi:10.1021/nn400482d · Cited by 814
Self-citationRecent advances in polyaniline based biosensors
Dhand, C., Das, M., Datta, M., & Malhotra, B. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.017 · Cited by 522
3D nanostructured conductive polymer hydrogels for high-performance electrochemical devices
Zhao, Y., Liu, B., Pan, L., & Yu, G. (2013) · Energy & Environmental Science · doi:10.1039/c3ee40997j · Cited by 396
Self-citationSun, C.-L., Chang, C.-T., Lee, H.-H., Zhou, J., Wang, J., Sham, T.-K., & Pong, W.-F. (2011) · ACS Nano · doi:10.1021/nn2015908 · Cited by 328
Dey, R. S., & Raj, C. R. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp105895a · Cited by 299
Singh, S., Solanki, P. R., Pandey, M. K., & Malhotra, B. D. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.10.025 · Cited by 206
Cited by
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Stimuli‐Responsive Biomolecule‐Based Hydrogels and Their Applications
Vázquez‐González, M., & Willner, I. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201907670 · Cited by 444
Han, L., Yan, L., Wang, M., Wang, K., Fang, L., Zhou, J., Fang, J., Ren, F., & Lu, X. (2018) · Chemistry of Materials · doi:10.1021/acs.chemmater.8b01446 · Cited by 438
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Ultrahigh‐Conductivity Polymer Hydrogels with Arbitrary Structures
Yao, B., Wang, H., Zhou, Q., Wu, M., Zhang, M., Li, C., & Shi, G. (2017) · Advanced Materials · doi:10.1002/adma.201700974 · Cited by 423
Metadata
- Authors
- Li, L., Wang, Y., Pan, L., Shi, Y., Cheng, W., Shi, Y., & Yu, G.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-01-12
- Volume
- 15
- Issue
- 2
- Pages
- 1146-1151
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2133064818
- Cited by
- 422
- References
- 22
- FWCI
- 19.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Nanostructured Conductive Hydrogels-Based Biosensor Platform for Human Metabolite Detection. https://app.cochat.ai/papers/10.1021/nl504217p
- The paper
- Li, L., Wang, Y., Pan, L., Shi, Y., Cheng, W., Shi, Y., & Yu, G. (2015). A Nanostructured Conductive Hydrogels-Based Biosensor Platform for Human Metabolite Detection. Nano Letters. https://doi.org/10.1021/nl504217p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.