The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Reservoir computing compensates slow response of chemosensor arrays exposed to fast varying gas concentrations in continuous monitoring
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks: Tricks of the Trade: Second Edition
(2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8 · Cited by 2,116
Information processing using a single dynamical node as complex system
Appeltant, L., Soriano, M. C., Van der Sande, G., Danckaert, J., Massar, S., Dambre, J., Schrauwen, B., Mirasso, C. R., & Fischer, I. (2011) · Nature Communications · doi:10.1038/ncomms1476 · Cited by 1,716
The importance of mixed selectivity in complex cognitive tasks
Rigotti, M., Barak, O., Warden, M. R., Wang, X.-J., Daw, N. D., Miller, E. K., & Fusi, S. (2013) · Nature · doi:10.1038/nature12160 · Cited by 1,639
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
A Practical Guide to Applying Echo State Networks
Lukoševičius, M. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8_36 · Cited by 867
Mead, M. I., Popoola, O. A. M., Stewart, G. B., Landshoff, P., Calleja, M., Hayes, M., Baldovi, J. J., McLeod, M. W., Hodgson, T. F., Dicks, J., et al. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.11.060 · Cited by 828
Chemical gas sensor drift compensation using classifier ensembles
Vergara, A., Vembu, S., Ayhan, T., Ryan, M. A., Homer, M. L., & Huerta, R. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.01.074 · Cited by 724
Self-citationPattern analysis for machine olfaction: a review
Gutierrez-Osuna, R. (2002) · IEEE Sensors Journal · doi:10.1109/jsen.2002.800688 · Cited by 578
De Vito, S., Massera, E., Piga, M., Martinotto, L., & Di Francia, G. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.09.060 · Cited by 544
Jaeger, H. (2007) · Scholarpedia · doi:10.4249/scholarpedia.2330 · Cited by 459
Cited by
Physical reservoir computing—an introductory perspective
Nakajima, K. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab8d4f · Cited by 422
Privacy-preserving distributed linear regression on high-dimensional data
Gascón, A., Schoppmann, P., Balle, B., Raykova, M., Doerner, J., Zahur, S., & Evans, D. (2017) · Proceedings on Privacy Enhancing Technologies · doi:10.1515/popets-2017-0053 · Cited by 193
Metadata
- Authors
- Fonollosa, J., Sheik, S., Huerta, R., & Marco, S.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2015-08
- Volume
- 215
- Pages
- 618-629
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2035729201
- Cited by
- 264
- References
- 30
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reservoir computing compensates slow response of chemosensor arrays exposed to fast varying gas concentrations in continuous monitoring. https://app.cochat.ai/papers/10.1016/j.snb.2015.03.028
- The paper
- Fonollosa, J., Sheik, S., Huerta, R., & Marco, S. (2015). Reservoir computing compensates slow response of chemosensor arrays exposed to fast varying gas concentrations in continuous monitoring. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2015.03.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.