Ultra-sensitive and selective hydrogen nanosensor with fast response at room temperature based on a single Pd/ZnO nanowire
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this work the gas sensing properties of nanosensors fabricated by a “bottom-up” approach in a FIB/SEM system based on a single Pd modified ZnO nanowire is investigated in detail. Synthesis, surface doping and functionalization of ZnO nanowires (NWs) with Pd (Pd/ZnO) in a one − step process were performed during electrochemical deposition. The influence of the diameter of the NW, the operating temperature and the humidity are studied in detail and corresponding sensing mechanisms are proposed. An increase in the gas response by a decrease of the NW diameter was observed. Also, by increasing the operating temperature to 200 °C an enhancement in the hydrogen gas response of about 3.5 times (from ≈400 to 1440 to 100 ppm) was obtained and was attributed to the increased catalytic properties of the Pd nanoparticles (NPs). However, long-term investigations revealed a lowered signal stability of the nanosensor operated at higher temperatures. Thus, one can conclude that operation at room temperature is more efficient for real applications, due to the higher reliability of the nanodevices. The presented results demonstrate the importance of nanosensor applications and their high flexibility. The very low current values in the passive regime (in the range of pA − nA) and a very small dimension of the device results in an ultra-low power consumption, which is a key aspect for battery powered handheld instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Recent advancements in Pt and Pt-free catalysts for oxygen reduction reaction
Nie, Y., Li, L., & Wei, Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00484a · Cited by 2,156
Cited by
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Recent advances in energy-saving chemiresistive gas sensors: A review
Majhi, S. M., Mirzaei, A., Kim, H. W., Kim, S. S., & Kim, T. W. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105369 · Cited by 653
“[134–136], noble metal NPs-decorated MOSs [137,138], doped MOSs [139,140], construction of heterojunction structures [141,142], hybrid”
Synergistic effects in gas sensing semiconducting oxide nano-heterostructures: A review
Walker, J. M., Akbar, S. A., & Morris, P. A. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.01.049 · Cited by 602
Advances in Noble Metal-Decorated Metal Oxide Nanomaterials for Chemiresistive Gas Sensors: Overview
Zhu, L.-Y., Ou, L.-X., Mao, L.-W., Wu, X.-Y., Liu, Y.-P., & Lu, H.-L. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01047-z · Cited by 553
Degler, D., Weimar, U., & Barsan, N. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00975 · Cited by 519
Metadata
- Authors
- Lupan, O., Postica, V., Labat, F., Ciofini, I., Pauporté, T., & Adelung, R.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-01
- Volume
- 254
- Pages
- 1259-1270
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2740482563
- Cited by
- 156
- References
- 2
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.