The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Detection and removal of antibiotic tetracycline in water with a highly stable luminescent MOF
Abstract
Abstract Antibiotic tetracycline (TC) is a sort of main contaminates in water, and of adverse effect on ecosystems and human health. The development of simple and efficient methods for both detection and removal of TC in water is highly desirable but remains challenging. Herein, a dual-functional platform for detection and removal of antibiotic tetracycline (TC) is developed by a highly stable luminescent zirconium-based MOF (PCN-128Y). The detection is based on the efficient luminescence quenching of the PCN-128Y toward TC. Theoretical/experimental studies reveal that the luminescence quenching can be attributed to a combined effect of the strong absorption of TC at the excitation wavelength and the photo-induced electron transfer process from the ligand of PCN-128Y to TC. The strong cheating metal-ligand bonding between Zr6 nodes and TC through solvent-assisted ligand incorporation is suggested to mainly account for the high adsorption capability of PCN-128Y toward TC in water. The preconcentration of TC within the pores of PCN-128Y induced by the adsorption process makes TC contact with the framework more sufficient, thus significantly enhances the efficiency of TC sensing. This work is the first example demonstrating that MOF materials can integrate the functions of detection and removal of antibiotic TC in water, which highlights the opportunity of luminescent MOFs in the application of wastewater treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Metal–organic frameworks: functional luminescent and photonic materials for sensing applications
Lustig, W. P., Mukherjee, S., Rudd, N. D., Desai, A. V., Li, J., & Ghosh, S. K. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00930a · Cited by 3,050
Zr-based metal–organic frameworks: design, synthesis, structure, and applications
Bai, Y., Dou, Y., Xie, L.-H., Rutledge, W., Li, J.-R., & Zhou, H.-C. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00837a · Cited by 2,545
Antibiotics and antibiotic resistance in water environments
Baquero, F., Martínez, J.-L., & Cantón, R. (2008) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2008.05.006 · Cited by 2,056
Hasan, Z., & Jhung, S. H. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.09.046 · Cited by 1,428
A Luminescent Mixed-Lanthanide Metal–Organic Framework Thermometer
Cui, Y., Xu, H., Yue, Y., Guo, Z., Yu, J., Chen, Z., Gao, J., Yang, Y., Qian, G., & Chen, B. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2108036 · Cited by 1,161
Lanthanide metal-organic frameworks for luminescent sensing and light-emitting applications
Cui, Y., Chen, B., & Qian, G. (2014) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2013.10.023 · Cited by 1,135
Postsynthetic Tuning of Metal–Organic Frameworks for Targeted Applications
Islamoglu, T., Goswami, S., Li, Z., Howarth, A. J., Farha, O. K., & Hupp, J. T. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00577 · Cited by 796
An Exceptionally Stable, Porphyrinic Zr Metal–Organic Framework Exhibiting pH-Dependent Fluorescence
Jiang, H., Feng, D., Wang, K., Gu, Z., Wei, Z., Chen, Y., & Zhou, H.-C. “. (2013) · Journal of the American Chemical Society · doi:10.1021/ja406844r · Cited by 740
Deria, P., Mondloch, J. E., Tylianakis, E., Ghosh, P., Bury, W., Snurr, R. Q., Hupp, J. T., & Farha, O. K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408959g · Cited by 591
Cited by
Du, C., Zhang, Z., Yu, G., Wu, H., Chen, H., Zhou, L., Zhang, Y., Su, Y., Tan, S., Yang, L., et al. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2020.129501 · Cited by 543
Metal organic framework based fluorescence sensor for detection of antibiotics
Marimuthu, M., Arumugam, S. S., Sabarinathan, D., Li, H., & Chen, Q. (2021) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.08.022 · Cited by 341
Kaur, H., Devi, N., Siwal, S. S., Alsanie, W. F., Thakur, M. K., & Thakur, V. K. (2023) · ACS Omega · doi:10.1021/acsomega.2c07719 · Cited by 273
Metadata
- Authors
- Zhou, Y., Yang, Q., Zhang, D., Gan, N., Li, Q., & Cuan, J.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 262
- Pages
- 137-143
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2793550392
- Cited by
- 331
- References
- 28
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and removal of antibiotic tetracycline in water with a highly stable luminescent MOF. https://app.cochat.ai/papers/10.1016/j.snb.2018.01.218
- The paper
- Zhou, Y., Yang, Q., Zhang, D., Gan, N., Li, Q., & Cuan, J. (2018). Detection and removal of antibiotic tetracycline in water with a highly stable luminescent MOF. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.01.218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.