The DOI matches its Crossref record.
Room temperature NO 2 gas sensor based on porous Co 3 O 4 slices/reduced graphene oxide hybrid
Abstract
The porous flake-like Co3O4 and Co3O4/graphene hybrids with different graphene contents were prepared through a facile two-step method. The field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) characterizations proved the tight adherence of graphene sheets to the surface of porous Co3O4 slices. Gas sensors based on the as-synthesized products were then fabricated to explore their potential applications. The results indicated that the optimal hybrid exhibited a response of 26.8% to 5 ppm of NO2 at room temperature (RT), which was 2.27 times higher than that of undoped Co3O4 (100 °C). The hybrid sensor also showed fast response, excellent selectivity, long-term stability and extremely low detection limit toward NO2 at RT. The significantly enhanced sensing properties to NO2 could be attributed to larger specific surface area, more chemisorbed oxygen species and the coupling effect between Co3O4 and graphene in the hybrid. As we all know, as a typical p-type semiconductor, the gas-sensing properties of Co3O4 toward oxidizing gases including NO2 was rarely reported. We believe that our work could pave the way for the future design of Co3O4-based gas sensors for oxidizing gases detection at low or even room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Advances in Noble Metal-Decorated Metal Oxide Nanomaterials for Chemiresistive Gas Sensors: Overview
Zhu, L.-Y., Ou, L.-X., Mao, L.-W., Wu, X.-Y., Liu, Y.-P., & Lu, H.-L. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01047-z · Cited by 553
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit
Sun, S., Wang, M., Chang, X., Jiang, Y., Zhang, D., Wang, D., Zhang, Y., & Lei, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127274 · Cited by 338
Recent Advances in Emerging 2D Material‐Based Gas Sensors: Potential in Disease Diagnosis
Zhang, L., Khan, K., Zou, J., Zhang, H., & Li, Y. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201901329 · Cited by 281
Metadata
- Authors
- Zhang, B., Cheng, M., Liu, G., Gao, Y., Zhao, L., Li, S., Wang, Y., Liu, F., Liang, X., Zhang, T., & Lu, G.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 263
- Pages
- 387-399
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2793614892
- Cited by
- 202
- References
- 0
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Room temperature NO 2 gas sensor based on porous Co 3 O 4 slices/reduced graphene oxide hybrid. https://app.cochat.ai/papers/10.1016/j.snb.2018.02.117
- The paper
- Zhang, B., Cheng, M., Liu, G., Gao, Y., Zhao, L., Li, S., Wang, Y., Liu, F., Liang, X., Zhang, T., & Lu, G. (2018). Room temperature NO 2 gas sensor based on porous Co 3 O 4 slices/reduced graphene oxide hybrid. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.02.117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.