The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit
Abstract
Abstract The development of gas sensor that is capable of detecting ppb-level detection of acetone and possesses high response toward low-concentration acetone remains a great challenge. Herein, we present the construction of the W18O49/Ti3C2Tx composites based on the in situ grown of the 1D W18O49 nanorods (NRs) on the surfaces of the 2D Ti3C2Tx Mxene sheets via a facile solvothermal process. The W18O49/Ti3C2Tx composites exhibit high response to low concentration acetone (11.6 to 20 ppm acetone), ideal selectivity, long-term stability, very low limit of detection of 170 ppb acetone, and fast response and recover rates (5.6/6 s to 170 ppb acetone). Compared to the W18O49 NRs and Ti3C2Tx sheets, the W18O49/Ti3C2Tx composites show significant improvement on the acetone-sensing performance, which can be ascribed to the homogeneous distribution of the W18O49 NRs on the Ti3C2Tx surface, the removal of the fluorine-containing groups from the Ti3C2Tx after the solvothermal process, and the synergistic interfacial interactions between the W18O49 NRs and the Ti3C2Tx sheets. The synthesis of the 1D/2D W18O49/Ti3C2Tx Mxene composites provides a new avenue to develop other promising hybrids for acetone sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Room Temperature Gas Sensing of Two-Dimensional Titanium Carbide (MXene)
Lee, E., VahidMohammadi, A., Prorok, B. C., Yoon, Y. S., Beidaghi, M., & Kim, D.-J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11055 · Cited by 878
Cited by
Ti3C2TX MXene for Sensing Applications: Recent Progress, Design Principles, and Future Perspectives
Pei, Y., Zhang, X., Hui, Z., Zhou, J., Huang, X., Sun, G., & Huang, W. (2021) · ACS Nano · doi:10.1021/acsnano.1c00248 · Cited by 799
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Self-citationChaudhary, V., Kaushik, A., Furukawa, H., & Khosla, A. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac5ac6 · Cited by 386
Metal oxide semiconductors for gas sensing
Goel, N., Kunal, K., Kushwaha, A., & Kumar, M. (2023) · Engineering Reports · doi:10.1002/eng2.12604 · Cited by 294
Peng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224
Metadata
- Authors
- Sun, S., Wang, M., Chang, X., Jiang, Y., Zhang, D., Wang, D., Zhang, Y., & Lei, Y.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 304
- Pages
- 127274
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2981265052
- Cited by
- 338
- References
- 2
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit. https://app.cochat.ai/papers/10.1016/j.snb.2019.127274
- The paper
- Sun, S., Wang, M., Chang, X., Jiang, Y., Zhang, D., Wang, D., Zhang, Y., & Lei, Y. (2020). W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2019.127274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.