Optical methods of antibiotic residues detections: A comprehensive review
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
This review paper presents the achievements and developments in the optical methods of antibiotic residues detection. The specific optical methods such as optical immunoassay methods, molecular spectroscopy detection methods, and optical fiber based detection methods are summarized in detail. And each of them was summarized and contrasted in a separate table, where the sensing structure, class of antibiotics and the limit of detection are all listed. Optical methods of antibiotic detections are widely used during the last two decades due to their short detection cycles, high sensitivity and simple operation, which are mainly researched for the food and water quality inspections. The future direction of sensing performances and application fields is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M., Moronne, M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,613
Extraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Otto, A. (1968) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01391532 · Cited by 3,065
Surface plasmons enhance optical transmission through subwavelength holes
Ghaemi, H. F., Thio, T., Grupp, D. E., Ebbesen, T. W., & Lezec, H. J. (1998) · Physical Review B · doi:10.1103/physrevb.58.6779 · Cited by 1,529
Cherenkov Radiation from Femtosecond Optical Pulses in Electro-Optic Media
Auston, D. H., Cheung, K. P., Valdmanis, J. A., & Kleinman, D. A. (1984) · Physical Review Letters · doi:10.1103/physrevlett.53.1555 · Cited by 648
The Use of the Avidin‐Biotin Complex as a Tool in Molecular Biology
Bayer, E. A., & Wilchek, M. (1980) · Methods of Biochemical Analysis · doi:10.1002/9780470110461.ch1 · Cited by 602
Kim, S., & Aga, D. S. (2007) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/15287390600975137 · Cited by 509
Bioapplications for Molecularly Imprinted Polymers
Schirhagl, R. (2014) · Analytical Chemistry · doi:10.1021/ac401251j · Cited by 372
Review of salinity measurement technology based on optical fiber sensor
Yu, Q., Zhao, Y., Wu, Q.-L., & Yang, Y. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.12.077 · Cited by 348
Ag/Graphene Heterostructures: Synthesis, Characterization and Optical Properties
Li, J., & Liu, C. (2010) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.200901048 · Cited by 317
Lossy mode resonance generation with indium-tin-oxide-coated optical fibers for sensing applications
Del Villar, I., Zamarreno, C. R., Hernaez, M., Arregui, F. J., & Matias, I. R. (2010) · Journal of Lightwave Technology · doi:10.1109/jlt.2009.2036580 · Cited by 285
Fernández, F., Hegnerová, K., Piliarik, M., Sánchez-Baeza, F. J., Homola, J., & Marco, M. ‐. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.06.012 · Cited by 200
Frasconi, M., Tel-Vered, R., Riskin, M., & Willner, I. (2010) · Analytical Chemistry · doi:10.1021/ac902944k · Cited by 195
Extraordinary sensitivity enhancement by metasurfaces in terahertz detection of antibiotics
Xie, L., Gao, W., Shu, J., Ying, Y., & Kono, J. (2015) · Scientific Reports · doi:10.1038/srep08671 · Cited by 194
A comprehensive review of lossy mode resonance-based fiber optic sensors
Wang, Q., & Zhao, W.-M. (2018) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2017.07.009 · Cited by 191
Self-citationLi, Y., Qu, L., Li, D., Song, Q.-X., Fathi, F., & Long, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.12.005 · Cited by 185
Antibiotics in agriculture: When is it time to close the barn door?
Lipsitch, M., Singer, R. S., & Levin, B. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.092142499 · Cited by 184
Efficient Emission from Core/(Doped) Shell Nanoparticles: Applications for Chemical Sensing
Thakar, R., Chen, Y., & Snee, P. T. (2007) · Nano Letters · doi:10.1021/nl0719168 · Cited by 170
Rebe Raz, S., Bremer, M. G. E. G., Haasnoot, W., & Norde, W. (2009) · Analytical Chemistry · doi:10.1021/ac901230v · Cited by 165
He, L., Lin, M., Li, H., & Kim, N. (2010) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2505 · Cited by 161
Optical fiber refractometers based on lossy mode resonances supported by TiO_2 coatings
Hernáez, M., Villar, I. D., Zamarreño, C. R., Arregui, F. J., & Matias, I. R. (2010) · Applied Optics · doi:10.1364/ao.49.003980 · Cited by 137
Terahertz spectroscopy: Its future role in medical diagnoses
Parrott, E. P. J., Sun, Y., & Pickwell‐MacPherson, E. (2011) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2011.05.048 · Cited by 134
Fan, W., Burnett, A. D., Upadhya, P. C., Cunningham, J. E., Linfield, E. H., & Davies, A. G. (2007) · Applied Spectroscopy · doi:10.1366/000370207781269701 · Cited by 122
Peng, C., Li, Z., Zhu, Y., Chen, W., Yuan, Y., Liu, L., Li, Q., Xu, D., Qiao, R., Wang, L., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.05.031 · Cited by 115
Qu, L., Liu, Y., Liu, M., Yang, G., Li, D., & Li, H. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b08790 · Cited by 113
Qin, J., Xie, L., & Ying, Y. B. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.05.059 · Cited by 111
Yan, D., Popp, J., Pletz, M. W., & Frosch, T. (2017) · ACS Photonics · doi:10.1021/acsphotonics.6b00688 · Cited by 108
Luo, Q., Yu, N., Shi, C., Wang, X., & Wu, J. (2016) · Talanta · doi:10.1016/j.talanta.2016.09.049 · Cited by 98
Determination of aqueous antibiotic solutions using SERS nanogratings
Hong, K. Y., de Albuquerque, C. D. L., Poppi, R. J., & Brolo, A. G. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.05.025 · Cited by 96
Rapid monitoring of antibiotics using Raman and surface enhanced Raman spectroscopy
Clarke, S., Littleford, R. E., Smith, W. E., & Goodacre, R. (2005) · The Analyst · doi:10.1039/b502540k · Cited by 94
Assessment of terahertz spectroscopy to detect antibiotic residues in food and feed matrices
Redo-Sanchez, A., Salvatella, G., Galceran, R., Roldós, E., García-Reguero, J.-A., Castellari, M., & Tejada, J. (2011) · The Analyst · doi:10.1039/c0an01016b · Cited by 88
Determination of β-Lactams in Milk Using a Surface Plasmon Resonance-Based Biosensor
Gustavsson, E., Degelaen, J., Bjurling, P., & Lundh, Å. S. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0344284 · Cited by 80
Qin, J., Xie, L., & Ying, Y. B. (2014) · Analytical Chemistry · doi:10.1021/ac503212q · Cited by 77
Breton, M.-H. L., Savoy, M., & Diserens, J.-M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.11.060 · Cited by 76
Detection of low concentrations of ampicillin in milk
Andreou, C., Mirsafavi, R. Y., Moskovits, M., & Meinhart, C. D. (2015) · The Analyst · doi:10.1039/c5an00864f · Cited by 76
Detection of Harmful Residues in Honey Using Terahertz Time-Domain Spectroscopy
Massaouti, M., Daskalaki, C., Gorodetsky, A. A., Koulouklidis, A. D., & Tzortzakis, S. (2013) · Applied Spectroscopy · doi:10.1366/13-07111 · Cited by 75
Rapid detection method for nitrofuran antibiotic residues by surface-enhanced Raman Spectroscopy
Xie, Y., Zhu, X., Sun, Y., Wang, H., Qian, H., & Yao, W. (2012) · European Food Research and Technology · doi:10.1007/s00217-012-1752-5 · Cited by 74
Korposh, S., Chianella, I., Guerreiro, A. R., Caygill, S., Piletsky, S. A., James, S. W., & Tatam, R. P. (2014) · The Analyst · doi:10.1039/c3an02126b · Cited by 73
Oral mycoses in avian scavengers exposed to antibiotics from livestock farming
Pitarch, A., Gil, C., & Blanco, G. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.144 · Cited by 64
Kong, D., Xie, Z., Liu, L., Song, S., Kuang, H., & Xu, C. (2017) · Food and Agricultural Immunology · doi:10.1080/09540105.2017.1293014 · Cited by 60
Traviesa-Alvarez, J. M., Costa-Fernandez, J. M., Pereiro, R., & Sanz‐Medel, A. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.02.063 · Cited by 58
Liu, X., Qiu, H., Huang, Y. J., Tang, Z., Tang, S., & Zhu, Z. (2015) · Food Analytical Methods · doi:10.1007/s12161-015-0164-0 · Cited by 51
Qin, J., Xie, L., & Ying, Y. B. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.12.064 · Cited by 47
Cantwell, H., & O’keeffe, M. (2005) · Food Additives & Contaminants · doi:10.1080/02652030500357433 · Cited by 43
SERS detection of expired tetracycline hydrochloride with an optical fiber nano-probe
Jin, D., Bai, Y., Chen, H., Liu, S., Chen, N., Huang, J., Huang, S., & Chen, Z. (2014) · Analytical Methods · doi:10.1039/c4ay02725f · Cited by 41
Determination of Sulfonamide Residues in Chicken Liver Using High-Performance Liquid Chromatography
Deng, K., Lan, X., Sun, G., Ji, L., & Zheng, X. (2016) · Food Analytical Methods · doi:10.1007/s12161-016-0514-6 · Cited by 34
Zhang, X., Pan, B., Yang, K., Zhang, D., & Hou, J. (2010) · Journal of Environmental Science and Health Part A · doi:10.1080/10934529.2010.506127 · Cited by 32
Chen, J., Feng, S., Gao, F., Grant, E. R., Xu, J., Wang, S., Huang, Q., & Lu, X. (2015) · Journal of Food Science · doi:10.1111/1750-3841.12825 · Cited by 30
A novel aptamer–quantum dot fluorescence probe for specific detection of antibiotic residues in milk
Wang, Y., Gan, N., Li, T., Cao, Y., Hu, F., & Chen, Y. (2016) · Analytical Methods · doi:10.1039/c6ay00412a · Cited by 29
Wu, C., Gan, N., Ou, C., Tang, H., Zhou, Y. F., & Cao, J. (2017) · RSC Advances · doi:10.1039/c6ra27337h · Cited by 16
Yuan, L., & Li, B. (2017) · International journal of agricultural and biological engineering · doi:10.25165/j.ijabe.20171005.2962 · Cited by 4
Cited by
Ahmadijokani, F., Molavi, H., Tajahmadi, S., Rezakazemi, M., Amini, M., Kamkar, M., Rojas, O. J., & Arjmand, M. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214562 · Cited by 224
Okoye, C. O., Nyaruaba, R., Ita, R. E., Okon, S. U., Addey, C. I., Ebido, C. C., Opabunmi, A. O., Okeke, E. S., & Chukwudozie, K. I. (2022) · Environmental Toxicology and Pharmacology · doi:10.1016/j.etap.2022.103995 · Cited by 183
Wang, Q., Jing, J.-Y., & Wang, B.-T. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2875961 · Cited by 183
“In order to couple the guide mode into the cladding for interaction with the surroundings, the optical fiber structure is generally modified, such as U-shaped geometry [12], tapered fibers [13], tilted fiber Bragg grating (TFBG) [14], [15], and photonic crystal fibers [16].”
BackgroundSelf-citationMoghzi, F., Foroshani, F. Z., Hedayati, Z., Soleimannejad, J., Kateshali, A. F., & Janczak, J. (2025) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2025.136320 · Cited by 3
Metadata
- Authors
- Wang, Q., & Zhao, W.-M.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 269
- Pages
- 238-256
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2802035058
- Cited by
- 182
- References
- 51
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.