Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly Sensitive SPR Biosensor Based on Graphene Oxide and Staphylococcal Protein A Co-Modified TFBG for Human IgG Detection

Wang, Qi, Jing, Jian-Ying, Wang, Bo-Tao · 2019 · IEEE Transactions on Instrumentation and Measurement

Abstract

A highly sensitive optical fiber surface plasmon resonance (SPR) biosensor based on graphene oxide (GO) and staphylococcal protein A (SPA) co-modified tilted fiber Bragg grating (TFBG) is proposed and demonstrated for the detection of human immunoglobulin G (IgG) for the first time. The gold film on the surface of the sensor was first fixed with GO and then modified with an SPA to improve the sensitivity of the sensor. Large specific surface area and abundant functional groups of GO can adsorb more antibodies. The combination of SPA and the antibody molecule Fc region makes the Fab area with antigen-binding sites extend outward, resulting in highly oriented antibody immobilization on the sensor surface and high antigen-antibody binding efficiency. The experimental results show that the sensitivity as well as the limit of detection of GO-SPA-modified TFBG-SPR biosensor is around 0.096 dB/($\mu \text{g}$ /mL) and $0.5~\mu \text{g}$ /mL, showing better responses to human IgG solutions with a concentration range of 30-$100~\mu \text{g}$ /mL compared with the TFBG-SPR biosensors modified singly with GO or SPA. The biosensor exhibits the advantages of small size, ease of fabrication, high sensitivity, label-free, and rapid response, and provides a new solution for detecting low concentration of biological solution, presenting great application potential in the biochemistry field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2018.2875961

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 183

Metadata

Authors
Wang, Q., Jing, J.-Y., & Wang, B.-T.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2019-09
Volume
68
Issue
9
Pages
3350-3357
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W2900206772
Cited by
183
References
1
FWCI
5.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Sensitive SPR Biosensor Based on Graphene Oxide and Staphylococcal Protein A Co-Modified TFBG for Human IgG Detection. https://app.cochat.ai/papers/10.1109/tim.2018.2875961
The paper
Wang, Q., Jing, J.-Y., & Wang, B.-T. (2019). Highly Sensitive SPR Biosensor Based on Graphene Oxide and Staphylococcal Protein A Co-Modified TFBG for Human IgG Detection. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2018.2875961

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.