The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Recent advances in microfluidic cell sorting systems
Abstract
Abstract Effective and high-throughput cell sorting are critical technologies in single cell analysis in biology, medicine and clinical applications. Especially for single cell analysis requiring high accuracy, multiple sorting mechanisms are required, and they need to be well organized into a system based on the sorting ability. Therefore, we classify most recent methods of microfluidic cell sorting as precise or large amount sorting methods based on the ability for sorting the number of cells. Precise sorting applies an instantaneous force (e.g. acoustic, electric, optical, and jet force) to displace cells a short distance to isolate them one by one with relatively high accuracy. Large amount methods use a continuous force (e.g. acoustic, electric, magnetic and passive force) to arrange, separate and purify cell populations with relatively high-throughput. By combining precise sorting and large amount sorting methods, it is possible to achieve a high-accuracy sorting system with high-throughput. Therefore, in this review, we summarized merits and demerits of these advanced technologies of sorting (focusing on those devices in the last five years that have features of high-throughput, portability and high efficiency) to suggest some suitable combinations of large amount and precise sorting methods; then we discussed the direction of single cell sorting and the prospects of the combined microchips.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Resolving early mesoderm diversification through single-cell expression profiling
Scialdone, A., Tanaka, Y., Jawaid, W., Moignard, V., Wilson, N. K., Macaulay, I. C., Marioni, J. C., & Göttgens, B. (2016) · Nature · doi:10.1038/nature18633 · Cited by 293
Self-citationRecent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
An integrated microfluidic device for rapid and high-sensitivity analysis of circulating tumor cells
Jiang, J., Zhao, H., Shu, W., Tian, J., Huang, Y., Song, Y., Wang, R., Li, E., Slamon, D., Hou, D., et al. (2017) · Scientific Reports · doi:10.1038/srep42612 · Cited by 66
Cited by
Local reaction environment in electrocatalysis
Chen, C., Jin, H., Wang, P., Sun, X., Jaroniec, M., Zheng, Y., & Qiao, S.-Z. (2024) · Chemical Society Reviews · doi:10.1039/d3cs00669g · Cited by 381
Tissue Engineering and Regenerative Medicine: Achievements, Future, and Sustainability in Asia
Han, F., Wang, J., Ding, L., Hu, Y., Li, W., Yuan, Z., Guo, Q., Zhu, C., Yu, L., Wang, H., et al. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00083 · Cited by 357
Metadata
- Authors
- Shen, Y., Yalikun, Y., & Tanaka, Y.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 282
- Pages
- 268-281
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2901127878
- Cited by
- 201
- References
- 3
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances in microfluidic cell sorting systems. https://app.cochat.ai/papers/10.1016/j.snb.2018.11.025
- The paper
- Shen, Y., Yalikun, Y., & Tanaka, Y. (2019). Recent advances in microfluidic cell sorting systems. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.11.025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.