The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Metal-organic frameworks-derived hollow zinc oxide/cobalt oxide nanoheterostructure for highly sensitive acetone sensing
Abstract
A high-performance acetone gas sensor based on metal-organic frameworks (MOFs)-derived ZnO/Co3O4 nano-heterostructure was prepared by a facile precipitation reaction method. The as-synthesized ZnO/Co3O4 nanocomposite was characterized by X-ray diffraction (XRD), thermo-gravimetric (TG), scanning electron microscopy (SEM), energy dispersive X-ray spectra (EDS), transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS), confirming its successful preparation and reasonability. The acetone sensing properties of ZnO/Co3O4 hollow polyhedron sample was investigated at the optimum working temperature of 300 °C. The experimental results reveal that the ZnO/Co3O4 nanocomposite has a significantly enhancement in acetone sensing performance, which showed high response, good linearity, short response/recovery time, excellent repeatability and outstanding selectivity. These results render the ZnO/Co3O4 hollow polyhedron an efficient sensing material for constructing high-performance acetone sensor. The mechanism of the enhanced acetone sensing performance were attributed to unique hollow nanostructure, catalytic effect of Co3O4 and the p-n heterojunctions in the ZnO/Co3O4 nanocomposite.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shannon, R. D. (1976) · Acta Crystallographica Section A · doi:10.1107/s0567739476001551 · Cited by 66,145
Cited by
Nanomaterials: a review of synthesis methods, properties, recent progress, and challenges
Baig, N., Kammakakam, I., & Falath, W. (2021) · Materials Advances · doi:10.1039/d0ma00807a · Cited by 3,262
Advances in Noble Metal-Decorated Metal Oxide Nanomaterials for Chemiresistive Gas Sensors: Overview
Zhu, L.-Y., Ou, L.-X., Mao, L.-W., Wu, X.-Y., Liu, Y.-P., & Lu, H.-L. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01047-z · Cited by 553
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Diversiform metal oxide-based hybrid nanostructures for gas sensing with versatile prospects
Zhang, D., Yang, Z., Yu, S., Mi, Q., & Pan, Q. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213272 · Cited by 347
Self-citationW18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit
Sun, S., Wang, M., Chang, X., Jiang, Y., Zhang, D., Wang, D., Zhang, Y., & Lei, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127274 · Cited by 338
Self-citation
Metadata
- Authors
- Zhang, D., Yang, Z., Wu, Z., & Dong, G.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 283
- Pages
- 42-51
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2902024202
- Cited by
- 202
- References
- 1
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal-organic frameworks-derived hollow zinc oxide/cobalt oxide nanoheterostructure for highly sensitive acetone sensing. https://app.cochat.ai/papers/10.1016/j.snb.2018.11.133
- The paper
- Zhang, D., Yang, Z., Wu, Z., & Dong, G. (2019). Metal-organic frameworks-derived hollow zinc oxide/cobalt oxide nanoheterostructure for highly sensitive acetone sensing. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.11.133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.