The DOI matches its Crossref record.
Hybrid polyaniline-WO3 flexible sensor: A room temperature competence towards NH3 gas
Abstract
Abstract In present study, a flexible, room temperature operable, and selective ammonia (NH3) sensor based on polyaniline and tungsten oxide (PAni-WO3) hybrid nanocomposite was successfully developed on polyethylene terephthalate (PET) substrate by in-situ chemical oxidative polymerization process and reported. Structural elucidation, surface morphology, and materials composition of flexible PAni-WO3 hybrid nanocomposites was analyzed systematically through X-ray diffraction, field emission scanning electron microscopy, transmission electron microscopy, and X-ray photoelectron spectroscopy, respectively. Gas sensing properties of flexible PAni-WO3 hybrid sensors was studied thoroughly and compared with pristine PAni and WO3 sensors. It was observed that the flexible sensor with 50 wt% WO3 content showed an excellent selectivity towards NH3 gas at room temperature along with 121% response towards 100 ppm. As-fabricated PAni-WO3 hybrid flexible sensors are capable to detect 1 ppm concentration of NH3 (Response = 9%) along with excellent stability and response reproducibility. Impedance spectroscopy was employed to quantify the gas sensing behavior of flexible PAni-WO3 sensor in presence of target gases and fresh air and resulting plots are simulated by equivalent circuits. Based on impedance results, the gas sensing mechanism of flexible PAni-WO3 nanocomposites in presence of NH3 atmosphere is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review on WO3 based gas sensors: Morphology control and enhanced sensing properties
Dong, C., Zhao, R., Yao, L., Ran, Y., Zhang, X., & Wang, Y. (2020) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2019.153194 · Cited by 434
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Porous materials as effective chemiresistive gas sensors
Sharma, A., Eadi, S. B., Noothalapati, H., Otyepka, M., Lee, H.-D., & Jayaramulu, K. (2024) · Chemical Society Reviews · doi:10.1039/d2cs00761d · Cited by 352
Wei, Y., Wang, H., Ding, Q., Wu, Z., Zhang, H., Tao, K., Xie, X., & Wu, J. (2022) · Materials Horizons · doi:10.1039/d2mh00284a · Cited by 66
Metadata
- Authors
- Kulkarni, S. B., Navale, Y. H., Navale, S. T., Stadler, F. J., Ramgir, N. S., & Patil, V. B.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 288
- Pages
- 279-288
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2918078165
- Cited by
- 197
- References
- 0
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid polyaniline-WO3 flexible sensor: A room temperature competence towards NH3 gas. https://app.cochat.ai/papers/10.1016/j.snb.2019.02.094
- The paper
- Kulkarni, S. B., Navale, Y. H., Navale, S. T., Stadler, F. J., Ramgir, N. S., & Patil, V. B. (2019). Hybrid polyaniline-WO3 flexible sensor: A room temperature competence towards NH3 gas. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2019.02.094
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.