Cited by 66Gas Sensing Nanomaterials and SensorsAdvanced Sensor and Energy Harvesting MaterialsConducting polymers and applications

Hydrogel- and organohydrogel-based stretchable, ultrasensitive, transparent, room-temperature and real-time NO 2 sensors and the mechanism

Wei, Yaoming, Wang, Hao, Ding, Qiongling, Wu, Zixuan, Zhang, He, Tao, Kai, Xie, Xi, Wu, Jin·2022·Materials Horizons

Abstract

Highly stretchable, transparent, ultrasensitive, selective and room-temperature NO 2 sensors are created by using ion-conductive hydrogels/organohydrogels. The electrodes play a key role in sensing performances and NO 2 tend to react at the cathode.

Integrity signals

Registry

Crossref · 10.1039/d2mh00284a

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications such as NO2, NH3, CO2, and O2.

    “Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications, such as NO2, NH3, CO2, and O2”
  • The CuSn anode displays better corrosion resistance than the Ag anode, leading to a prolonged lifespan.

    “In addition to the increased sensitivity, the CuSn anode displays better corrosion resistance than that with the Ag anode, leading to a prolonged lifespan.”
  • The sensor features excellent selectivity for NO2 and still works well at 50% tensile strain.

    “The sensor also features excellent selectivity for NO2 and still works well at 50% tensile strain.”
  • The authors implemented wireless sensing of NO2 by collecting and processing data from real-time monitoring; when NO2 concentration exceeds the threshold, both the smartphone and the alarm system give an early warning.

    “Even further, the authors implemented wireless sensing of NO2 by collecting and processing data from real-time monitoring. When the concentration of NO2 exceeds the threshold, both the smartphone and the alarm system will give an early warning, as shown in Fig. 8d.”
  • The sensor can withstand 1,400% tensile strain due to its unique DN structure, exhibits a high sensitivity of 60.02% ppm−1 and an ultralow LOD of 6.8 ppb NO2.

    “The sensor can not only withstand 1,400% tensile strain due to its unique DN structure, but also exhibits a high sensitivity of 60.02% ppm−1 and the ultralow LOD of 6.8 ppb NO2.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wei, Y., Wang, H., Ding, Q., Wu, Z., Zhang, H., Tao, K., Xie, X., & Wu, J.
Affiliations
  • Sun Yat-sen University (CN)
  • South China University of Technology (CN)
  • Northwestern Polytechnical University (CN)
Corresponding author
Wu, Jin
Venue
Materials Horizons
Published
2022
Volume
9
Issue
7
Pages
1921-1934
ISSN
  • 2051-6347 (ISSN-L)
  • 2051-6355
OpenAlex
W4226065900
Cited by
66
References
2
Citations by year
2026: 3 · 2025: 13 · 2024: 7 · 2023: 26 · 2022: 17
FWCI
4.31
Type
journal article
Language
en
Open access
closed
Locations
  • Materials Horizons (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (61801525)
  • Basic and Applied Basic Research Foundation of Guangdong Province (2020A1515010693)
  • Fundamental Research Funds for the Central Universities (22lgqb17)
  • Guangzhou Municipal Science and Technology Project (201904010456)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
NO2 gas sensor, stretchable sensors, transparent sensors, hydrogels, organohydrogel, room-temperature sensing, real-time gas sensing, ultrasensitive detection, electrode design
MeSH terms
Electrodes, Nitrogen Dioxide, Temperature, Hydrogels

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review