Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

An acetone gas sensor based on nanosized Pt-loaded Fe2O3 nanocubes

Zhang, Shendan, Yang, Mingjie, Liang, Kunyu, Turak, Ayse, Zhang, Bingxue, Meng, Da, Wang, Chuanxi, Qu, Fengdong, Cheng, Wenlong, Yang, Minghui·2019·Sensors and Actuators B: Chemical

Abstract

Abstract Nanosized Pt-loaded Fe2O3 nanocubes are prepared through, successively, a simple hydrothermal reaction, two-step annealing process and finally reduction with NaBH4 of H2PtCl4. The resultant Pt decorated Fe2O3 nanocubes, made up of Fe2O3 nanoplatelets, are hierarchical, hollow and porous, with an average edge length of 200–300 nm. The sensor based on Pt decorated Fe2O3 nanocomposites exhibits higher response (Rair/Rgas = 25.7) to 100 ppm of acetone gas at lower temperature (139 °C), with a short response-recovery time (3 s/22 s), compared with pure Fe2O3 nanocubes sensor. The Pt-Fe2O3 nanocomposite sensor shows excellent potential to act as a low cost, low temperature sensor for acetone gas, with high acetone selectivity under high humidity conditions and with the interference of other gases. Under various environmental conditions designed to mimic exhaled air, the sensor is able to detect ppb amounts of acetone, with high repeatability and stability, making it suitable for applications such as oral diabetic sensors. The attractive chemical and electronic sensitizations of partially oxidized Pt nanoparticles are responsible for the enhancement of acetone sensing performance. Based on the high acetone selectivity, high stability and fast dynamic response, the Pt enhanced Fe2O3 nanocubes sensor is an exceptionally suitable candidate for a low cost acetone sensor, and the proposed approach provides a route to develop gas sensors that can operate at low temperatures for a wide variety of applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2019.03.082

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 265

Metadata

Authors
Zhang, S., Yang, M., Liang, K., Turak, A., Zhang, B., Meng, D., Wang, C., Qu, F., Cheng, W., & Yang, M.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2019-07
Volume
290
Pages
59-67
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2926694748
Cited by
265
References
21
FWCI
11.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An acetone gas sensor based on nanosized Pt-loaded Fe2O3 nanocubes. https://app.cochat.ai/papers/10.1016/j.snb.2019.03.082
The paper
Zhang, S., Yang, M., Liang, K., Turak, A., Zhang, B., Meng, D., Wang, C., Qu, F., Cheng, W., & Yang, M. (2019). An acetone gas sensor based on nanosized Pt-loaded Fe2O3 nanocubes. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2019.03.082

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.