CoChat
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A colorimetric paper sensor based on the domino reaction of acetylcholinesterase and degradable γ-MnOOH nanozyme for sensitive detection of organophosphorus pesticides

Huang, Lunjie, Sun, Da-Wen, Pu, Hongbin, Wei, Qingyi, Luo, Linpin, Wang, Jianlong · 2019 · Sensors and Actuators B: Chemical

Abstract

Despite the tremendous achievements of existing sensing techniques, sensitive and portable sensing of organophosphorus pesticides (OPs) in a non-polluting manner remains a challenging issue. This work proposed a facile colorimetric paper sensor using γ-MnOOH nanowires (NWs) as a degradable nanozyme and 3,3′,5,5′-tetramethylbenzidine (TMB) as a chromogenic indicator for rapid and sensitive screening of OPs and acetylcholinesterase (AChE) activity. The sensing mechanism was based on the easy disintegration of the oxidase-like γ-MnOOH NWs into invalid Mn2+ ions by the selective reaction with thiocholine (TCh) produced by AChE and acetylthiocholine iodide (ATCh), triggering a remarkable activity loss of MnOOH nanozymes towards TMB oxidation. The concentration of OPs, as an AChE inhibitor, was measured by the changes in absorbance at 652 nm or blue color of oxTMB products. Such detection platform in solution state achieved relatively low limits of detection (LODs) for AChE activity (0.007 mU mL−1), and for two typical OPs, i.e., omethoate (0.35 ng mL−1) and dichlorvos (0.14 ng mL−1), respectively. Further, the portable assembly of such AChE-nanozyme tandem reaction on test paper performed well, reaching LODs of 0.1 mU mL−1 for AChE, 10 ng mL−1 for omethoate, and 3 ng mL−1 for dichlorvos, respectively. Meanwhile, this sensing system showed great selectivity and anti-interfering capacity in both solution and solid states, and worked well in real serum and vegetable samples. The abovementioned results, along with evidence of its good ecological sustainability, demonstrated the superiority of this well-performing platform for application in the food, environmental, and medical fields.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2019.04.020

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Huang, L., Sun, D.-W., Pu, H., Wei, Q., Luo, L., & Wang, J.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2019-07
Volume
290
Pages
573-580
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2934972840
Cited by
167
References
1
FWCI
6.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.